For building owned or used by the commonwealth of Massachusetts, a gas
fitting permit shall be filed with? - Correct answer State board of
examiners of plumbers and gas fitters



Plastic gas pipe and fitting may only be used? - Correct answer Outside
underground



The change in diameter of a vent terminal shall be made by the use of an
increaser and occur no less than how far below the roof? - Correct answer
12''



Unvented gas room heaters shall have a maximum BTU input of: - Correct
answer 40,000 BTU



What is the maximum distance allowed between cleanouts in a 4"
horizontal drain? - Correct answer 50'



An appliance that operates woth a positive vent static pressure and with a
vent gas temperature that can cause excessive condensation is defined
as? - Correct answer Category lV



Who has the authority to revoke a LP installers license? - Correct answer
State board of examiners of plumbers and gas fitters




Alaska Plumbing License cert 2024 exam actual questions and answers

,Alaska



When two or more vent connectors enter a common gas vent or chimney
flue, the smaller of the two shall enter the vertical? - Correct answer
Above the larger



9) When installing water piping to a specific fixture, said piping shall be
full size to within how many inches of the fixture itself? - Correct answer
30"



When installing plastic gas piping outside underground it must be? -
Correct answer Installed with corrosion resistant tracer wire (14 gauge)



What is the minimum size of the horizontal waste between the lavatory on
the left and the stack? - Correct answer Answer: 2"



12) The remaining space surrounding a chimney liner, gas vent, special
gas vent, or plastic piping installed within a masonry chimney? - Correct
answer Answer: shall not be used to vent another appliance



13) The inlet area of the strainer for a roof drain may not be less than? -
Correct answer Answer: 1-1/2 times the area of the conductor



14)Exposed PVC piping used for combustion air or to discharge flue gases
must be labeled every? - Correct answer 10 Feet



15) Are you allowed to indirect waste a pre-rinse sink for a dishwasher in a
commercial kitchen? - Correct answer NO



16) During each renewal cycle, gas fitters and undiluted liquefied
petroleum gas installers must complete how many hours of continued
education? - Correct answer Answer: Six




Alaska Plumbing License cert 2024 exam actual questions and answers

, Alaska



17) When installing a gas line underground inside a building, what is not
required with the conduit installed around the gas line? - Correct
answer Answer: it must be of the same material as the gas pipe



18) The acceptance range for a PH adjustment tank in an acid
neutralization system is? - Correct answer Answer: 6-9



19) When installing a gas appliance on a roof, what is the minimum
distance from the appliance to theedge of the roof? Answer: 6 feet -
Correct answer Answer: 6 feet



20) An electric water heater installed in a commercial application having a
storage capacity of over 120 gallons must have? - Correct answer
Answer An ASME rating (American society of mechanical engineers)



21) Burners with a firing rate of 1,000,000 BTU shall be equipped with the
following? - Correct answer Answer: a proven low fire start



22) How long does an apprectice need to retain their W-2 forms after
passing the journeyman exam? Correct answer Answer: 7 years



23) Before a gas piping system is put into operation, it must be pressure
tested for a period of? - Correct answer Answer: 10 minutes



24) True or false. You may install a trap on an indirect waste main? -
Correct answer Answer: false



25) When purging gas to an outside location from a piping system, how far
away from a source of ignition must the termination be? - Correct
answer Answer: 10 feet




Alaska Plumbing License cert 2024 exam actual questions and answers

Información del documento

Subido en
28 de mayo de 2026
Número de páginas
25
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$21.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Examdoctor1
3.7
(6)
Vendido
33
Seguidores
12
Artículos
2986
Última venta
2 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes