The regulations to enforce compliance of underground storage tank systems in the state are found in? a.) Code of Federal Regulations, 40 CFR Part 281 b.) California Code of Regulations, Title 23, Chapter 16 c.) Code of Federal Regulations, 40 CFR Part 280 d.) California Code of Regulations, Title 23, Chapter 17 - Answer b.) California Code of Regulations; Title 23, Chapter 16 By definition an "underground storage tank system" includes a.) The tank, all connected piping and dispensers b.) The tank, all connected piping, ancillary equipment and containment system c.) Only the tank d.) Only tanks totally beneath the surface of the ground - Answer b.) The tank, all connected piping, ancillary equipment and containment system (H&SC, Sec 25281(z)) Under-dispenser containment was required for all UST systems by ___________. a.) December 31, 2003 b.) July 1, 1987 c.) January 1, 1984 d.) January 1, 2000 - Answer a.) December 31, 2003 CCR Title 23, Sec 2636(g)(C) According to California Law, UST systems installed after July 1, 2003, require a one-time ELD test to ensure that the tank is product tight...

Vista previa del contenido

UST: Final Questions to Study All
Answered Correct Graded A+
2026/2027 Edition.
The regulations to enforce compliance of underground storage tank systems in the state are
found in?



a.) Code of Federal Regulations, 40 CFR Part 281

b.) California Code of Regulations, Title 23, Chapter 16

c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17 - Answer b.) California Code of
Regulations; Title 23, Chapter 16



By definition an "underground storage tank system" includes



a.) The tank, all connected piping and dispensers

b.) The tank, all connected piping, ancillary equipment and containment system

c.) Only the tank

d.) Only tanks totally beneath the surface of the ground - Answer b.) The tank, all connected
piping, ancillary equipment and containment system



(H&SC, Sec 25281(z))



Under-dispenser containment was required for all UST systems by ___________.



a.) December 31, 2003

b.) July 1, 1987

c.) January 1, 1984

d.) January 1, 2000 - Answer a.) December 31, 2003



CCR Title 23, Sec 2636(g)(C)



According to California Law, UST systems installed after July 1, 2003, require a one-time ELD test
to ensure that the tank is product tight...



a.) If the tank is located within one (1) mile of a public drinking water well

,b.) If the tank is located within 1000 feet of a public drinking water well

c.) Unless the tank is equipped with secondary containment

d.) In all cases - Answer For ALL tanks before use (H&SC 25290.2 (I))

d.) In all cases



H&SC, Sec 25290.2(i)



The written report submitted to the local agency after an unauthorized release is required to
include the following except:



a.) Description of actions taken to stop the release

b.) Cause of the release

c.) Method of disposal of released product

d.) Date on which the release was discovered - Answer b.) Cause of the release



CCR Title 23, Sec 2652(c)



An unauthorized release which does not escape from secondary containment only requires a
record on the operator's monitoring reports provided:



A. It did not increase the hazard of fire

B. It did not cause any deterioration of the secondary containment

C. It was cleaned up within 8 hours of detection

D. All of the above - Answer D. All of the above



H&SC, Sec 25294



The annual monitoring certification may be performed by:



A. A person possessing the appropriate contractors licenses

B. An individual trained and certified by the manufacturer of the monitoring equipment

C. A designated UST operator

D. A person who meets the requirements of both a and b - Answer D. A person who meets
the requirements of both a and b



CCR Title 23, Sec 2715(i)

,The following is true of secondary containment testing, EXCEPT:



a.) Must be tested every 24 months

b.) Must be tested every 36 months

c.) Results must be submitted to the local agency within 30 days of testing

d.) Local agency must be notified 48 hours prior to testing - Answer a.) Must be tested every
24 months



CCR Title 23, Sec 2637(a)



Records of cathodic protection system maintenance must be kept on file for ______________.



a.) 10 years

b.) 1.5 years

c.) 3 years

d.) 6.5 years - Answer d.) 6.5 years



CCR Title 23, Sec 2712(b)



Impressed current cathodic protection systems shall be inspected no less than every
___________ to ensure that they are in proper working order:



a.) 60 days

b.) 90 days

c.) 30 days

d.) 120 days - Answer a.) 60 days



CCR Title 23, Sec 2635(a)(2)



Monthly monitoring data must be kept on file for _________________.



a.) 3 years

b.) 6.5 years

c.) 5 years

, d.) For the life of the UST system - Answer a.) 3 years



CCR Title 23, Sec 2712(b)



By December 22, 1998, all automatic line leak detectors installed on single-walled pressurized
piping must be capable of:



a.) Restricting product flow

b.) Triggering an audible and visual alarm

c.) Shutting down the pumping system

d.) Shutting off the flow at the dispenser - Answer c.) Shutting down the pumping system



CCR Title 23, Sec 2666(c)



When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate
a post-test hard copy data report of the following information, except:



a.) Liquid volume

b.) Fuel depth

c.) Outside air temperature

d.) Time and date of test - Answer c.) Outside air temperature



CCR Title 23, Sec 2643(b)(1)



If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert the transfer
operator when the tank is no more than ___________ full



a.) 85%

b.) 95%

c.) 90%

d.) 80% - Answer c.) 90%



CCR Title 23, Sec 2635(b)(2)(A)



A service technician has performed calibration and maintenance on an ATG probe; this
maintenance record must be kept on file for ______________.

Información del documento

Subido en
26 de mayo de 2026
Número de páginas
50
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TestSolver9
3.5
(168)
Vendido
966
Seguidores
128
Artículos
30969
Última venta
15 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes