Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

FRESENIUS HD FINAL EXAM QUESTIONS AND ANSWERS

Puntuación
-
Vendido
-
Páginas
10
Grado
A+
Subido en
24-05-2026
Escrito en
2025/2026

FRESENIUS HD FINAL EXAM QUESTIONS AND ANSWERS

Institución
FRESENIUS
Grado
FRESENIUS

Vista previa del contenido

FRESENIUS HD FINAL EXAM
QUESTIONS AND ANSWERS



When washing hands with soap and water how long must you wash your hands? -
Correct Answers -40 - 60 seconds

When cleaning hands with hand sanitizer how long must you rub your hands? - Correct
Answers -20 - 30 seconds

The number one cause of chronic renal failure is? - Correct Answers -Diabetes Mellitus

When going from a dirty area to retrieve supplies in a clean area, staff are required to
complete hand hygiene T/F ? - Correct Answers -True

The first bleach solution used to clean a large blood spill area
(> 10 ml) is ? - Correct Answers -1:10 One part bleach nine parts water

Hazardous Material Identification System (HMIS) labels are required on all hazardous
materials, including individual bicarbonate containers: T/F ? - Correct Answers -True

The main route of transmission of Hepatitis B in hemodialysis facilities is by exposure to
infected ____________ and ____________ fluids. - Correct Answers -blood and bodily

When caring for a patient who is Hepatitis B positive, after disconnecting the bloodlines,
the technician MUST perform which 3 actions before documenting? - Correct Answers -
Remove gloves, sanitize hands, and don a fresh pair of gloves.

According to the CDC, patients who are Hepatitis B surface Antigen (HBsAg) positive
should be dialyzed in a ______________ area of the dialysis center, on a
_______________ machine. - Correct Answers -separate / dedicated

What must the dialysis technician do prior to leaving the patient at the dialysis station to
get clean supplies? Remove ___________, ______________ hands and retrieve items.
- Correct Answers -gloves, sanitize/wash

You must wear a full-face shield, or mask with goggles, when in an area with a risk of
______________________. - Correct Answers -blood splatter

, Use of diasafe filter allows the production of _______________. - Correct Answers -
ultrapure dialysate

Normal ___________ is used to rinse and prime the tubing of the extracorporeal circuit
to remove sterilant and air. - Correct Answers -saline

Air is removed from the extracorporeal circuit before initiating treatment because it may
cause ____________ when trapped in the dialyzer. - Correct Answers -clotting

The most likely cause of contamination of the extracorporeal circuit are
_______________ in the prime bucket with ________________ end caps. - Correct
Answers -bloodlines / open

A low-level arterial drip chamber can result in _______________ entering the system
causing an air embolism or clotting. - Correct Answers -air

______________________ is the ability of a substance to conduct an electrical charge.
- Correct Answers -Conductivity

When blood escapes from the dialyzer blood compartment into the dialysate fluid
compartment this is known as a _________ __________. - Correct Answers -blood leak

The final dialysate must have an pH between _________ and ___________. - Correct
Answers -6.9 and 7.6

How often should staff clean the dialysis machine with acid? - Correct Answers -Daily

Before the start of treatment, check that the machine's conductivity alarm parameters
are set at ______________ of the machine's theoretical conductivity. - Correct Answers
-+/- 0.5 mS

What is removed by normal saline during the priming process? - Correct Answers -Air in
the dialyzer

When should alarm and pressure holding tests (PHT) be performed on a dialysis
machine? - Correct Answers -Before each treatment

You should disinfect the dialysis machine with heat after doing what? - Correct Answers
-After cleaning with acid.

In addition to safety checks, what tests must you perform to ensure a safe patient
treatment? __________________ and _________________ - Correct Answers -meter
conductivity and pH

Why do you compare the machine conductivity setting to the meter conductivity results?
- Correct Answers -To ensure machine display is accurate

Escuela, estudio y materia

Institución
FRESENIUS
Grado
FRESENIUS

Información del documento

Subido en
24 de mayo de 2026
Número de páginas
10
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$15.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
mereka Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
478
Miembro desde
3 año
Número de seguidores
215
Documentos
9436
Última venta
1 semana hace
anchor

on this page, you will find all documents, package deal

3.8

92 reseñas

5
45
4
15
3
14
2
6
1
12

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes