LICENSING PRACTICE QUESTIONS AND ANSWERS A+ VERIFIED LATEST VERSION
1. What must you have signed by the customer before entering into a contract
on a property that is currently under an active wdo warranty?: Form 13671 (consumer
consent form)
2. The eastern sub termite belongs to what family?: Rhinotermitidae
3. Drywood and dampwood termites belong to the family?: Kalotemritidae
4. according to the revised taxonomy of termites, these insects belong in the
order along with cockroaches: Blattodae
5. the Old House Borer is a example of?: Longhorned wood borer
6. which is required to be reported on the Form 13645?: Evidence, Damage and live
organisms
7. When must you use a form 13645 inspection report?: For real estate transactions,
and for real estate transactions when a written report is requested
8. which is the minimum amount of errors on omissions liability insurance?: -
$500,000/$250,00
9. which are the two documents that can give you guidance on completing a
form 13645 inspection report?: The industry baseline practices and the guidelines for the use and
completion of the form 13645
10. Under the definition as they pertain to wdo inspections, live or living would
include all of the following EXCEPT?: powerpost beetle frass streaming out of holes
11. under the definitions as they pertain to wdo inspections, structures would
include all of the following but not?: detached private fences
12. you would report damage and deterioration to particle board and masonry
siding caused by exposure to water and sunlight, including the delamination
water stains, peeling, separation and other break down cellulose materials on
a form 13645 inspection report: false
13. which of these items could be stated as areas excluded from an exterior of a
structure from the form 13645 inspection report?: stored items and debris stacked against
the structure
14. which of the following is not an example of a conducive condition that may
lead to the presence of wood destroying organisms?: wood roof shingles
15. which would not be a valid reason for excluding the inspection of the entire
attic of a structure?: insulation covers trust trails
1/9
, FLORIDA TERMITE EXAM 2019 – WDO INSPECTION, TERMITICIDES, AND PEST CONTROL
LICENSING PRACTICE QUESTIONS AND ANSWERS A+ VERIFIED LATEST VERSION
16. conducive conditions for termite or wood decaying fungi infestations would
include all of the following but not?: oak trees located on the property
17. if you do not properly check any boxes in Section 3 (obstructions and
inaccessible areas) on form 13645, then you have indicated that?: the area was
inspected and considered accessible
18. as part of the wdo inspection, evidence of a wood destroying organism
would not include?: Ambrosia Beetle stains
19. the purpose of the wdo inspection report is to communicate information
about the presence or absence of wood destroying organisms at the time of
the inspection, therefore, it is considered to be warrantied for?: none of the above
20. according to the industry Baseline practices, what is the minimum opening
size for an attic entrance?: 20" x 20"
21. according to the industry Baseline practices what is the minimum opening
size through the truss webbing in the Attic?: 22" x 48"
22. which of the following reasons would not allow you to exclude the crawl
space of a structure from The Forum 13645 inspection?: plastic vapor Barrier on the
ground
23. which one of the following would not be evidence of previous treatment of
a structure during a form 13645 inspection?: drill holes in a tree stump
24. which are the two categories of application equipment used for subter-
ranean termites soil treatments?: above-ground and below-ground
25. what is the basic reason to use foam instead of a liquid termiticide: foam flows
around pipes and other debris
26. the following are examples of above ground application equipment accept-
ing?: sub-slab injector
27. which is the federal statutes that regulate the pest control industry?: Federal
Insecticide Fungicide rodenticide Act
28. in Florida which of the following statutory chapters covers the pesticide
storage facility?: chapter 252
29. which of the following statutory chapters covers pesticide spill reporting in
Florida?: chapter 252
2/9