Which of the following lamps provides a continuous spectrum of radiant energy in the visible,
near IR, and near UV regions of the spectrum?



A. Tungsten-filament

B. Hydrogen

C. Deuterium

D. Mercury Vapor - correct answer: A. Tungsten-filament



Which of the following isolates light within a narrow region of the spectrum?



A. Photomultiplier tube

B. Monochromator

C. Photovoltaic cell

D. Detector - correct answer: B. Monochromator



Which of the following is not descriptive of a photomultiplier tube?



A. Emits electrons proportionally to initial light absorbed

B. Must be shielded from stray light

C. Cannot be used with a chopper

D. Amplifies the initial signal received - correct answer: C. Cannot be used with a chopper



Which of the following is false about a photomultiplier tube?

,A. Converts radiant energy (light) to electrical energy (current)

B. Amplifies the current significantly

C. Has a very rapid response time

D. Is composed of an iron plate and a layer of selenium - correct answer: D. Is composed of an
iron plate and a layer of selenium



Which type of photodetector employs a linear arrangement that allows it to respond to a
specific wavelength resulting in complete UV/visible spectrum analysis?



A. Photomultiplier tube

B. Phototube

C. Barrier layer cell

D. Photodiode array - correct answer: D. Photodiode array



When performing spectrophotometer quality assurance checks, what is the holmium oxide glass
filter used to assess?



A. Linearity

B. Stray light

C. Absorbance accuracy

D. Wavelength accuracy - correct answer: D. Wavelength accuracy



In spectrophotometric analysis, what is the purpose of the reagent blank?



A. Correct for interfering chromogens

B. Correct for lipemia

,C. Correct for protein

D. Correct for color contribution of the reagents - correct answer: D. Correct for color
contribution of the reagents



In regard to bichromatic analysis, which of the following is false?



A. Absorbance is measured at the spectral absorbance peak for a blank and the sample using
the same wavelength.

B. Eliminates background interferences

C. Sample concentration determined from difference in two measured absorbances

D. Functions as a reference blank for each sample - correct answer: A. Absorbance is measured
at the spectral absorbance peak for a blank and the sample using the same wavelength.



The bandpass of a spectrophotometer is 10 nm. If an instrument is set at 540 nm, the
wavelengths that are permitted to impinge on the sample will be within what wavelength
range?



A. 530-540 nm

B. 530-550 nm

C. 535-545 nm

D. 540-550 nm - correct answer: C. 535-545 nm



Which of the following formulas is an expression of the Beer-Lambert law that is routinely
applied to spectrophotometric analysis?



A. Aᵤ X (Cs/As) = Cᵤ

B. Cᵤ X (Cs/As) = Aᵤ

C. As X (Cs/Cᵤ) = Aᵤ

, D. A = 2 - log %T - correct answer: A. Aᵤ X (Cs/As) = Cᵤ



In spectrophotometry, which of the

following is a mathematical expression of the relationship between absorbance and
transmittance?



A. A = abc

B. (Aᵤ/Cᵤ) = (As/Cs)

C. A = 2 - log %T

D. A = log %T - correct answer: C. A = 2 - log %T



Which of the following is not a problem inherent in turbidimetry?



A. Variation in particle size of samples

B. Variation in particle size of standards

C. Rate of aggregation or settling of particles

D. Need to maintain a constant and specific temperature - correct answer: D. Need to maintain
a constant and specific temperature



Which of the following may be associated with reflectance spectrophotometry as it relates to
the dry reagent slide technique?



A. Light projected to the slide at 180-degree angle

B. Dye concentration directly proportional to reflectance

C. Unabsorbed, reflected light detected by photodetector

D. Reflectance values are linearly proportional to transmission values - correct answer: C.
Unabsorbed, reflected light detected by photodetector

Escuela, estudio y materia

Institución
Chapter - Clinical Chemistry Study Revision
Grado
Chapter - Clinical Chemistry Study Revision

Información del documento

Subido en
19 de mayo de 2026
Número de páginas
134
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
wambuimorris901

Conoce al vendedor

Seller avatar
wambuimorris901 nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
-
Miembro desde
2 meses
Número de seguidores
0
Documentos
165
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes