●● Local governmental agency responsible for enforcing building and
other related Codes and regulations.
Answer: Building Department
●● In general, emergency lighting should provide illumination for all
types of egress components with an average illumination of at least
____________foot-candle at floor level
Answer: 1
●● NFPA Standard that deals with the Fire Safety and Emergency
Symbols is:
Answer: 170
●● To alter the appearance of a building, room, or series of rooms is
called______?
Answer: remodel
●● In general a set of plans is composed of six major sections. Which is
NOT one of these sections?
,a. Occupancy Standards
b. Plumbing
c. Structural
d. Mechanical
Answer: Occupancy Standards
●● A section drawing is made by passing an imaginary cutting
__________ through a building or part of a building
Answer: Plane
●● Refrigeration machinery room will be required to have a
___________hour Fire Rated separation from the remainder of the
occupancy unless it is sprinklered.
Answer: 1
●● The _______(or plot) plan is usually one of the rst sheets of a set of
construction drawings
Answer: Site
●● Utility drawings are plot plans that show the location of utilities
serving a property
Answer: true
,●● _______________Codes require that a Fire Alarm System have the
capability of closing elevators to public use during a fire
Answer: building
●● Overpressure is air pressure below normal or atmospheric pressure.
Answer: true
●● Heat detectors for basic wet chemical systems are usually fusible
link, although electronic heat detector that do not use fusible links can
also be used
Answer: true
●● A sketch depicting the general arrangement of the property in
reference to streets, adjacent properties, and other important features is
known as a(n):
Answer: site plan
●● There are three types of electrical power, direct current (DC),
alternating current (AC) and cycle current (CC)
Answer: false
●● Many authorities having jurisdiction DO NOT require design
contractors to have a third party peer review conducted on all
performance-base-designs
, Answer: false
●● Fire and Emergency Services Access Roads include which of these
requirements?
a. Minimum inside/outside radii
b. Acceptable surface
c. Minimum width
d. All choices are correct
Answer: All choices are correct
●● Heat detectors include the following types EXCEPT
a. fixed temperature
b. rate of compensation
c. deluge
d. rate-of-rise
Answer: deluge
●● Water pipes must be protected from freezing, which is generally
accomplished by burying the pipes at least _______ft below the frost
line
Answer: 1