Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 41 páginas
Examen

NCCT SURGICAL TECH PRACTICE EXAM QUESTIONS WITH CORRECT ANSWERS

Document preview thumbnail
Vista previa 4 fuera de 41 páginas

NCCT SURGICAL TECH PRACTICE EXAM QUESTIONS WITH CORRECT ANSWERS

Vista previa del contenido

NCCT SURGICAL TECH PRACTICE EXAM
QUESTIONS WITH CORRECT ANSWERS

While preparing to do an abdominal hysterectomy on a 500 pound female the
| | | | | | | | | | | | |


surgical technologist begins to retrieve supplies and instrumentation. Which of
| | | | | | | | | |


the following retractor systems should the technologist retrieve for this case? -
| | | | | | | | | | | |


CORRECT ANSWER✔✔-Bookwalter |




An emaciated patient is scheduled for an abdominal hysterectomy with removal
| | | | | | | | | | |


of excessive skin on bilateral thighs. The circulator has opted to place the ESU
| | | | | | | | | | | | | |


grounding pad on the patient's forearm. The surgical technologist should suggest
| | | | | | | | | | |


that the ESU pad be removed and placed on - CORRECT ANSWER✔✔-the
| | | | | | | | | | | |


buttocks


Which of the following are done during the initial count for a tubal ligation case?
| | | | | | | | | | | | | | |


(Select the three (3) correct answers.) - CORRECT ANSWER✔✔-state the name of
| | | | | | | | | | | |


each item as you begin to count it, circulator records the items counted, count
| | | | | | | | | | | | | |


laps, Raytecs, needles, and blades
| | | |




The surgical technologist has just completed scrubbing for a repair of an
| | | | | | | | | | | |


abdominal aneurysm. The aneurysm repair ruptures during transport from the
| | | | | | | | | |


operating room bed to the stretcher. Which of the following actions should the
| | | | | | | | | | | | |


surgical technologist take next? - CORRECT ANSWER✔✔-Don new gown and
| | | | | | | | | |


gloves.

,Which of the following is used to help maintain hemostasis intraoperatively in
| | | | | | | | | | | |


neurosurgery? - CORRECT ANSWER✔✔-raney clips | | | |




Which of the following instruments should be passed to the surgeon to achieve
| | | | | | | | | | | | |


hemostasis at the beginning of an operative procedure? (Select the three (3)
| | | | | | | | | | | |


correct answers.) - CORRECT ANSWER✔✔-electrosurgical pen, sponge, suction
| | | | | | | |


device


The patient will need surgical skin prep for a right arm disarticulation at the
| | | | | | | | | | | | | |


shoulder. Which of the following is the correct method for completing this prep? -
| | | | | | | | | | | | |


|CORRECT ANSWER✔✔-Begin at shoulder to finger tips, including flank and chest,
| | | | | | | | | | |


prepping the axilla last, using as many sponges as needed, keeping the arm away
| | | | | | | | | | | | | |


from the bed.
| |




When disinfecting a flexible endoscope used on a patient with TB, which of the
| | | | | | | | | | | | | |


following sterilization methods should be employed? - CORRECT ANSWER✔✔-
| | | | | | | |


steris


During a total hip replacement, how can a surgical technologist prevent blood
| | | | | | | | | | | |


from drying on instruments? - CORRECT ANSWER✔✔-Place the instruments in a
| | | | | | | | | | |


basin of sterile water.
| | |




Which of the following prep solutions is contraindicated for use with a laser? -
| | | | | | | | | | | | | |


CORRECT ANSWER✔✔-Duraprep |




In the Sterile Processing Department, a DART test for autoclave steam sterilizers
| | | | | | | | | | | |


should be run - CORRECT ANSWER✔✔-daily.
| | | | |

,Upon opening a sterilized instrument tray, the surgical technologist finds
| | | | | | | | | |


bioburden inside the lumen of a metal suction. Which of the following actions
| | | | | | | | | | | | |


should the surgical technologist take? - CORRECT ANSWER✔✔-Remove the
| | | | | | | | |


sterilized instrument tray from the sterile field.
| | | | | |




The surgeon requests a non-absorbable suture for skin closure. Which of the
| | | | | | | | | | | |


following sutures is non-absorbable? - CORRECT ANSWER✔✔-Nylon
| | | | | |




The anesthesia provider would typically ask the surgical technologist how much
| | | | | | | | | | |


fluid has been used in order to - CORRECT ANSWER✔✔-estimate blood loss.
| | | | | | | | | | |




Postoperatively a hernia repair patient complains of ulnar pain, numbness and
| | | | | | | | | | |


tingling bilaterally. The most likely cause of the patient's discomfort is that the
| | | | | | | | | | | | |


surgical technologist forgot to - CORRECT ANSWER✔✔-place arm pads.
| | | | | | | |




The surgical technologist must discard a malfunctioning sterilant and replace with
| | | | | | | | | |


a new one. Where should the technologist look to find the proper disposal
| | | | | | | | | | | | | |


protocol for this product? - CORRECT ANSWER✔✔-hospital MSDS log
| | | | | | | |




When steam sterilizing biological indicators, how long are they incubated before
| | | | | | | | | | |


the reading is recorded? - CORRECT ANSWER✔✔-24 hours
| | | | | | |




Ten minutes into an automatic chemical washer cycle for an instrument string,
| | | | | | | | | | | |


the surgical technologist notices she has missed a few critical instruments. Which
| | | | | | | | | | | |


of the following should the technologist do? - CORRECT ANSWER✔✔-Wait until
| | | | | | | | | | |


the washer stops and run a new cycle with the instruments.
| | | | | | | | | |

, During an otorhinolaryngologic procedure, which of the following precautions
| | | | | | | | |


should the surgical technologist take if the anesthesia provider is using an
| | | | | | | | | | | |


uncuffed endotracheal tube? - CORRECT ANSWER✔✔-Moisten sponges and place
| | | | | | | |


around the field prior to start of procedure to minimize leakage and reduce heat
| | | | | | | | | | | | | | |


buildup.


Which of the following should the surgical technologist do immediately before
| | | | | | | | | | |


connecting the Jackson-Pratt drain to the drainage tubing? - CORRECT
| | | | | | | | | |


ANSWER✔✔-Squeeze the bulb to apply manual suction. | | | | | |




Prior to a case the surgical technologist determines the power saw is not
| | | | | | | | | | | | |


functioning. Which of the following is the most likely cause? - CORRECT
| | | | | | | | | | | |


ANSWER✔✔-The battery has not been adequately charged. | | | | | |




The surgical technologist places the patient in Fowler position with head secured
| | | | | | | | | | | |


by craniotomy headrest. Which of the following locations indicates correct
| | | | | | | | | |


application of the safety strap? - CORRECT ANSWER✔✔-2 inches above the knees
| | | | | | | | | | |




Which of the following is the minimum number of counts for a Cesarean section
| | | | | | | | | | | | | |


case? - CORRECT ANSWER✔✔-four
| | |




At the end of each case the surgical technologist should - CORRECT ANSWER✔✔-
| | | | | | | | | | | |


rinse blood from the instruments with sterile water.
| | | | | | |

Información del documento

Subido en
17 de mayo de 2026
Número de páginas
41
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$17.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectphilip
4.1
(43)
Vendido
277
Seguidores
6
Artículos
25801
Última venta
3 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes