A ____ device is used for connecting the outlets of one or more gas cylinders to the
central piping system? - answer Manifold

A factory assembled product designed for anesthetics or convenience that contains
medical gas outlets or vacuum inlets, piping, or other related to medical gases is a ____
? - answer Manufactured assembly

A warning system within an area uses a ____
that provides continuous visible and audible
surveillance of category 1 and category 2 medical gas and vacuum systems? - answer
Area alarm

After coolers where required shall be provided with individual ____ ? - answer
Condensate traps

Carbon monoxide shall activate a local alarms when the CO level exceeds ____? -
answer10 ppm

Compressors that are monitored for gases hydrocarbons shall be monitored on a ____
basis - answerQuarterly

Filters shall be efficient to ____ and 99.7% HEPA or better per. DOE-STD-3020 -
answer0.3

Medical air shall be sampled at a ____ NPS valve sample port downstream of the final
line pressure regulator? - answer1/4 inch

The minimum clearance around the EOSC for a temporary sore is ____ feet? - answer3
feet

The monitor shall be capable of monitoring ____ percent oxygen concentration with one
percent accuracy? - answer99

Within a single patient room or critical care area to provide access for two or more
gases through a common delivery system, which would be used? - answerSurface
mounted medical gas rail system also known as MGR

Which of the following systems shall not be permitted to be located in an outdoor
enclosure? - answermedical air sources

, What type of connection should be used to connect the medical air compressors for a
vacuum pumps to their intake an outlet piping? - answerFlexible

What is not part of a typical category one medical gas vacuum system? - answerPatient
lead

What is part of a typical category one medical gas vacuum system? - answerAn inlet at
locations where patient suction could be, pressure, gauges, and operating controls, shut
off valves

What is a pneumatic terminous of a pipe gas system? Other than critical continuous
duty, non-flammable, medical gas life support type gases. - answerService outlet

What guide is for preparation of precautionary, labeling, and marketing of compressed
gas containers? - answerCGA C-7

Vacuum filtration shall be sized for ____ percent of the peak calculated demand while
one filter or filter bundle is isolated. - answer100

Vacuum filtration shall be at least ____ to allow one filter to be exchanged without
impairing the vacuum system? - answerDuplex

Louvered openings for natural ventilation shall have a minimum free area of ____? -
answer72 square inches

Medical air filters shall be located immediately upstream of the ____? - answerFinal line
regulators

Cylinders and use an in storage shall be prevented reaching temperature is an excess
of ____? - answer125 Fahrenheit

All pressure relief valve shall be made of brass, bronze, or ____? - answerStainless
steel

A category one dedicated WAGD source shall consist of ____ or more producers, each
shall be sufficient to serve the peak calculated demand - answer2

A variant on the cryogenic liquid container manifold shall be permitted to have three
headers. Such a variant shall have a minimum of ____ connections required for each of
the primary and secondary headers. - answer2

For each oxygen concentrator a local alarm to indicate low oxygen concentration when
a concentration lower than ____ percent is observed? - answer91

Medical air compressors shall be provided with a ____ restart function, such that the
compressors will be restarted after a power interruption? - answerAutomatic

Información del documento

Subido en
15 de mayo de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
julianah420
4.2
(157)
Vendido
712
Seguidores
328
Artículos
35903
Última venta
3 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes