What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete. - answer-Gently press the concrete around the temperature measuring device at the surface of the concrete The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - answer-3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - answer-1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. - answer-Annually, accuracy The temperature of concrete may be measured in a wheelbarrow. True or False? - answer-True The temperature of concrete may be measured in a wall form. True of False - answer-True

Mostrar más Leer menos
Institución
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1
Grado
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1

Vista previa del contenido

ACI CONCRETE FIELD TESTING
TECHNICIAN GRADE 1 PRACTICE
TEST EXAM

What must be done to the concrete
surrounding the temperature measuring
device after the device is submerged in the
fresh concrete. - answer-Gently press the
concrete around the temperature
measuring device at the surface of the
concrete


The sensor of the temperature measuring
device shall be submerged a minimum of
_____ in. [_____mm] into the freshly mixed
concrete. - answer-3 in. [75 mm]

,The temperature measuring device shall
have a capacity of measuring temperature
of freshly mixed concrete to +- _____
degrees F [+- _____ C] throughout a range
of _____. - answer-1 degree F [0.5 C], 30
degrees F to 120 F [0 C to 50 C]


The temperature measuring device shall be
calibrated _____, or whenever there is a
question of _____. - answer-Annually,
accuracy


The temperature of concrete may be
measured in a wheelbarrow. True or False?
- answer-True


The temperature of concrete may be
measured in a wall form. True of False -
answer-True

,A composite sample of concrete is
required even if the only purpose for
obtaining the sample is to determine
temperature. True of False? - answer-
False


What must be done to the sample container
prior to sampling the concrete? - answer-
Dampen (with water)


How long must the temperature measuring
device remain in the freshly mixed
concrete? - answer-At least 2 minutes but
not more than 5 minutes


After the temperature of the concrete is
read, what is required? - answer-Reporting
of temperature

, The temperature of concrete is reported to
the nearest _____ degrees F [_____ C] -
answer-1 degree F [0.5 C]


According to ASTM C1064, what is one
reason to take the temperature of
concrete? - answer-Verify conformance to
a specified requirement for temperature of
concrete


A maximum temperature of freshly mixed
concrete is specified in ASTM C1064. True
of False? - answer-False


The sample of concrete used for
temperature determination must be rodded
25 times. True or False? - answer-False

Escuela, estudio y materia

Institución
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1
Grado
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1

Información del documento

Subido en
14 de mayo de 2026
Número de páginas
40
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$19.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
docciel NURSING
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
25
Miembro desde
3 año
Número de seguidores
11
Documentos
1207
Última venta
1 día hace

5.0

3 reseñas

5
3
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes