what are the difference between calibration sensitivity and analytical sensitivity - ANSWERScalibration sensitivity is the slope of a calibration curve at the concentration of interest while analytical sensitivity is a response to the noise ratio how to calculate calibration sensitivity - ANSWERSy=mx+b (m is the calibration sensitivity) graph concentration vs mean analytical signal how to find the analytical sensitivity - ANSWERSAs (concentation) = calibration sensitivity/SD [ ] how to find the coefficient of variation for the mean of each of the replicate sets - ANSWERSCV = SD/Average x 100 how to find the detection limit for method? - ANSWERS3.3*SD(blank)/calibration sensitivity voltage in a series - ANSWERSVt = Vc + Vb + Va Voltage in a parallel circuit - ANSWERS1/Veff = 1/Va + 1/Vb Capacitance in a series - ANSWERS1/Ceff = 1/Ca + 1/Cb capacitance equals - ANSWERSQ/V

Vista previa del contenido

INSTRUMENTAL ANALYSIS ACS
FINAL PREP 2026

what are the difference between calibration sensitivity and analytical sensitivity -
ANSWERScalibration sensitivity is the slope of a calibration curve at the concentration
of interest while analytical sensitivity is a response to the noise ratio

how to calculate calibration sensitivity - ANSWERSy=mx+b (m is the calibration
sensitivity)
graph concentration vs mean analytical signal

how to find the analytical sensitivity - ANSWERSAs (concentation) = calibration
sensitivity/SD [ ]

how to find the coefficient of variation for the mean of each of the replicate sets -
ANSWERSCV = SD/Average x 100

how to find the detection limit for method? - ANSWERS3.3*SD(blank)/calibration
sensitivity

voltage in a series - ANSWERSVt = Vc + Vb + Va

Voltage in a parallel circuit - ANSWERS1/Veff = 1/Va + 1/Vb

Capacitance in a series - ANSWERS1/Ceff = 1/Ca + 1/Cb

capacitance equals - ANSWERSQ/V

if a spectrum is the result of a single scan while another is the result of multiple scans,
how man individual spectra were summed to increase S/N from 4.2 to 43?
a) formula?
b) answer - ANSWERSa) (S/N)a = sqrt(n) (S/N)b
b) 105

what type of noise can be reduced by decreasing the temperature of a measurement -
ANSWERSthermal noise

what type of noise can be reduced by decreasing the frequency used for the
measurement - ANSWERSflicker noise

what type of noise can be reduced by decreasing the bandwidth of the measurement -
ANSWERSenvironmental noise

, What would be an appropriate source and detector to determine the emission lines for
lithium from 200 to 780 nm? - ANSWERSflame and photo multiplier tube (PMT)

you've been asked to measure the UV absorbance of a sample containing poly cyclic
aromatic hydrocarbons, a byproduct of the incomplete combustion of organic matter.
What would be an appropriate material for the sample container? - ANSWERSfused
silica or quartz

which of the following changes will result in a decreased effective bandwidth?
a) increasing the number of blazes in the monochromatic grating
b) switching from a short-pass filter to a long-pass filter
c) increasing sample concentration
d) decreasing the amount of stray light - ANSWERSa

what would be the distance between blazes for a grating where the first order diffraction
line for 600 nm light is reflected at 10 degrees and the angle of incidence light is 45
degrees?
a) formula
b) answer - ANSWERSa) n(wavelength) = distance*(sin(i)+sin(r))
b) 680 nm

which of the following would be considered a discontinuous wavelength selector?
a) quartz prism
b) Czerny-Turner Grating (monochormator)
c)interference filter
d)glass prism - ANSWERSc

which characteristics are desirable for a radiation transducer?
a) high sensitivity to short wavelength light
b) low S/N ratio
c) consistent high output when not illuminated
d) constant response over large wavelength range
e) all of the above - ANSWERSd

what is the appropriate process for atomization for AAS and AES? (3 steps) -
ANSWERSdesolvation, vaporization, atomization

the doppler effect is one reason for line broadening in atomic spectroscopy. What is the
effect on a measured signal? - ANSWERSmovement of excited atoms toward the
detector causes a shortening in the wavelength of the emitted light

it is better to select an excitation source for AAS with ____bandwidth -
ANSWERSsmaller

Información del documento

Subido en
7 de mayo de 2026
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
papersmaster01
3.9
(73)
Vendido
302
Seguidores
106
Artículos
14701
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes