Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

468_PA_PH 468 - Pennsylvania (Philadelphia) Demolition Class B Practice Exam Questions And Correct Answers (Verified Answers) Plus Explanation 2026 Q&A | Instant Download Pdf.

Puntuación
-
Vendido
-
Páginas
58
Grado
A+
Subido en
28-04-2026
Escrito en
2025/2026

468_PA_PH 468 - Pennsylvania (Philadelphia) Demolition Class B Practice Exam Questions And Correct Answers (Verified Answers) Plus Explanation 2026 Q&A | Instant Download Pdf.

Institución
468_PA_PH 468 - Pennsylvania
Grado
468_PA_PH 468 - Pennsylvania

Vista previa del contenido

468_PA_PH 468 - Pennsylvania (Philadelphia)
Demolition Class B Practice Exam Questions And
Correct Answers (Verified Answers) Plus Explanation
2026 Q&A | Instant Download Pdf.

Question 1:
What defines a "Major Building" according to A-1001.1 of the Philadelphia
Administrative Code?

 A) Buildings taller than 5 stories
 B) Buildings with a total area of more than 20,000 square feet
 C) Buildings that are more than 3 stories high, more than 40 feet tall, or cover 10,000
square feet or more
 D) All buildings in the commercial district

Correct Answer: C
Explanation: A Major Building is specifically defined by the Philadelphia Code as exceeding
3 stories, 40 feet in height, OR 10,000 square feet of lot space. Meeting any one of these
thresholds classifies the structure as Major, which generally requires a Class A license .




Question 2:
What is the maximum height for a building to be considered for Class B demolition if it
is not designated as a Major Building?

 A) 30 feet
 B) 40 feet
 C) 50 feet
 D) 60 feet

Correct Answer: B
*Explanation: Buildings not designated as Major Buildings and intended for Class B
demolition must be no more than 40 feet in height. The 40-foot demarcation is a key
threshold between Class B and Class A licensing .*

, Question 3:
A client requests a bid to demolish a single-story warehouse that is 35 feet tall and
covers 9,500 square feet of lot space. Is this within the scope of a Class B Demolition
Contractor license?

 A) No, because it is a commercial building
 B) Yes, because it is under 40 feet tall and under 10,000 square feet
 C) No, because it exceeds 5,000 square feet
 D) Yes, because it is only one story

Correct Answer: B
*Explanation: Class B demolition covers buildings that are NOT "Major Buildings." Since
this warehouse is under the 40-foot height limit (35 ft) and under the 10,000 sq ft
threshold (9,500 sq ft), it qualifies for Class B scope .*




Question 4:
For a building to be classified under Class B demolition, what is the maximum lot space
it may cover?

 A) 5,000 square feet
 B) 7,500 square feet
 C) Less than 10,000 square feet
 D) 12,000 square feet

Correct Answer: C
Explanation: The Major Building threshold is 10,000 square feet or more. Therefore, for
Class B eligibility, the building must cover less than 10,000 square feet of lot space. If it
covers 10,000 sq ft or more, it is a Major Building requiring Class A oversight .




Question 5:
Which code outlines the demolition requirements for buildings not classified as Major
Buildings in Philadelphia?

, A) Title 4 of the Philadelphia Building and Occupancy Code
 B) International Building Code (IBC)
 C) Uniform Building Code (UBC)
 D) National Electrical Code (NEC)

Correct Answer: A
Explanation: Title 4 of the Philadelphia Building and Occupancy Code specifically outlines
the demolition requirements for buildings in Philadelphia, including the classification of
Major Buildings and scope of work for Class B contractors .




Section 2: Permits & Regulatory Framework
Question 6:
Which Philadelphia government department is responsible for enforcing demolition
codes and issuing demolition permits?

 A) Philadelphia Police Department (PPD)
 B) Philadelphia Fire Department (PFD)
 C) Department of Licenses and Inspections (L&I)
 D) Department of Streets

Correct Answer: C
Explanation: The Department of Licenses and Inspections (L&I) is the regulatory body that
oversees all code enforcement, licensing, and permitting for demolition in Philadelphia .




Question 7:
What is the mandatory bond amount required for a Class B demolition contractor
license in Philadelphia?

 A) $5,000
 B) $10,000
 C) $25,000
 D) $50,000

, Correct Answer: B
Explanation: Class B demolition contractors must provide a license bond
for 10,000withanoriginalseal.ClassArequiresa10,000withanoriginalseal.ClassA
requiresa50,000 bond. The bond ensures financial restitution to the city or property
owners if the contractor violates regulations .




Question 8:
Which of the following documents must be obtained before starting demolition work?

 A) Demolition permit
 B) New construction permit
 C) Landscaping permit
 D) Parking permit

Correct Answer: A
Explanation: A demolition permit must be obtained from L&I before starting any
demolition work. Operating without a permit results in Stop Work Orders and significant
fines .




Question 9:
What is the online system used by the City of Philadelphia for submitting demolition
permit applications?

 A) eCLIPSE
 B) L&I Direct
 C) Philly Permits Portal
 D) PA Construction Online

Correct Answer: A
Explanation: eCLIPSE (Electronic Construction License and Inspection System) is
Philadelphia's online portal for submitting demolition permit applications, attaching
required documents, and scheduling L&I inspections .

Escuela, estudio y materia

Institución
468_PA_PH 468 - Pennsylvania
Grado
468_PA_PH 468 - Pennsylvania

Información del documento

Subido en
28 de abril de 2026
Número de páginas
58
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$26.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
studyguidepro NURSING
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
257
Miembro desde
10 meses
Número de seguidores
12
Documentos
2297
Última venta
17 horas hace
verified exams

Updated exams .Actual tests 100% verified.ATI,NURSING,PMHNP,TNCC,USMLE,ACLS,WGU AND ALL EXAMS guaranteed success.Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied. **Ace Your Exams with Confidence!**

3.6

49 reseñas

5
21
4
4
3
13
2
5
1
6

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes