(Restricted Systems) Newest 2026 Update
Complete 150 Questions And Correct Detailed
Answers (Most Tested Verified Questions) |Already
Graded A+||Brand New Version!!
Georgia Class II Electrical Contractor Exam (Restricted Systems) style. It follows
NEC-based practice, Georgia licensing focus, business/law, safety, grounding,
circuits, and low-rise electrical systems
1. Electrical Safety & Code Basics
1. What is the primary purpose of the NEC?
A. Design architectural plans
B. To provide safety standards for electrical installations
C. To regulate utility companies
D. To approve electrical licenses
Explanation: NEC ensures safe installation practices to protect people and
property.
2. Who enforces electrical code compliance at job sites?
A. OSHA
B. Utility company
C. Local electrical inspector / authority having jurisdiction (AHJ)
D. Manufacturer
Explanation: AHJ ensures installations meet code requirements.
3. Which NEC article covers general requirements?
A. Article 250
, B. Article 300
C. Article 110
D. Article 210
Explanation: Article 110 covers installation standards and safety.
4. Electrical grounding primarily serves to:
A. Increase voltage
B. Reduce load
C. Provide a safe path for fault current
D. Store energy
Explanation: Grounding protects people from shock hazards.
5. Which organization publishes the NEC?
A. OSHA
B. IEEE
C. NFPA
D. National Fire Protection Association (NFPA)
Explanation: NFPA publishes NEC (NFPA 70).
2. Licensing & Georgia Rules
6. Georgia Class II electrical contractor license is:
A. Restricted to HVAC only
B. Limited to fire alarm only
C. Unrestricted electrical contracting work
D. Limited to lighting only
Explanation: Class II allows broad electrical work scope.
7. Minimum age requirement for Georgia electrical contractor license is:
A. 18
B. 19
C. 21
D. 25
Explanation: State licensing requires maturity and experience.
, 8. Minimum experience required for Class II license is typically:
A. 1 year
B. 2 years
C. 4 years qualified electrical experience
D. 10 years
Explanation: Georgia requires documented field experience.
9. Passing score on Georgia electrical contractor exam is:
A. 60%
B. 65%
C. 70%
D. 80%
Explanation: Minimum passing requirement is 70%.
10.Which license is more restrictive?
A. Class II
B. Class I
C. Master electrician
D. Unlimited contractor
Explanation: Class I has service limitations.
3. Ohm’s Law & Electrical Theory
11.Ohm’s Law formula is:
A. P = IV
B. V = IR
C. I = PR
D. R = VP
Explanation: Voltage equals current × resistance.
12.If voltage increases and resistance stays constant, current will:
A. Decrease
B. Increase
C. Stay same
, D. Stop
Explanation: Direct proportional relationship.
13.Power formula is:
A. V = IR
B. P = VI
C. R = VI
D. I = V/R²
Explanation: Electrical power equals voltage × current.
14.Unit of electrical resistance is:
A. Volt
B. Amp
C. Ohm
D. Watt
Explanation: Resistance is measured in ohms (Ω).
15.If 120V is applied to a 12Ω resistor, current is:
A. 5A
B. 10A
C. 12A
D. 120A
Explanation: I = V/R = 120/12 = 10A.
4. Wiring Methods & Conductors
16.NM cable is typically used for:
A. Underground systems
B. Industrial plants
C. Residential wiring
D. High voltage transmission
Explanation: NM (Romex) is used in homes.
17.Conductor size is determined by:
A. Color