LOW GWP REFRIGERANT EXAM AND
PRACTICE EXAM 2026/2027 WITH ACTUAL
CORRECT QUESTIONS AND VERIFIED
DETAILED ANSWERS |CURRENTLY TESTING
QUESTIONS AND SOLUTIONS|ALREADY
GRADED A+|NEWEST |BRAND NEW VERSION!!|
|JUST RELEASED
Before beginning the installation of a system that is charged with an A2L refrigerant:


a local code official must approve the site of the installation.


NFPA 704 hazard placards must be placed in visible locations around the perimeter of the
jobsite.


permanent mechanical ventilation must be installed in the structure.


verify that all the components being installed are designed for use with A2L refrigerants.

verify that all the components being installed are designed for use with A2L refrigerants.

When installing a system that is charged with a flammable refrigerant, which of the
following can be installed to energize mitigation responses?


Active refrigerant sensor.


Combustion gas leak detector.


Passive refrigerant sensor.




1|Page

,Wi-Fi enabled digital thermostat.

Active refrigerant sensor.

Intrinsically safe electrical components:


can be operated in wet locations or underwater.


can be worked on while live within a flammable atmosphere.


can only be operated while being monitored by a service professional.


can operate outside of their listed design conditions for a brief period.

can be worked on while live within a flammable atmosphere.

When performing service on the electrical components of a system that is charged with an
A2L refrigerant, which of the following is an unacceptable practice?


Discharging all capacitors with a screwdriver prior to beginning any repair.


Replace components only with parts specified by the manufacturer (OEM).


Verify that the system is properly grounded prior to beginning any repair.


When the system is de-energized, employ proper lockout and tagout procedures.

Discharging all capacitors with a screwdriver prior to beginning any repair.

Patterns of adding refrigerant to an A2L system of at least once per three-year period,
should be considered:



2|Page

, a symptom of a faulty compressor.


proof of a leak.


verification of the efficiency of any installed mitigation strategies.


within the range of permissible emissions.

proof of a leak

After reaching the required recovery level on a system that is charged with an A2L
refrigerant:


a nitrogen sweep should be done to remove any residual refrigerant vapor.


an alcohol-based solution must be used to remove any oil or grease.


the refractive index of the compressor must be tested.


the system must stand idle for 60 minutes prior to beginning any work on it.

a nitrogen sweep should be done to remove any residual refrigerant vapor.

After installation, the refrigerant piping for an A2L system must be:


cleaned with an alcohol-based solution to remove grease and oil.


pressurized with dry nitrogen to perform a leak test.


pressurized with a non-flammable refrigerant (A1) to perform a leak test.


vibration tested using whichever method is approved by the local code authority.

3|Page

Información del documento

Subido en
20 de abril de 2026
Número de páginas
19
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$17.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Drgary
4.6
(1402)
Vendido
532
Seguidores
217
Artículos
3285
Última venta
1 día hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes