NYC GAS CODE EXAM QUESTIONS AND ANSWERS Where is the union located for a gas appliance? - CORRECT ANSWERA union fitting shall be provided for appliance connected by rigid metallic pipe. Such unions shall be accessible and located within 6 feet of the appliance.

Mostrar más Leer menos
Institución
NYC GAS CODE
Grado
NYC GAS CODE

Vista previa del contenido

NYC GAS CODE EXAM QUESTIONS AND ANSWERS
Where is the union located for a gas appliance? - CORRECT ANSWER✅✅A union fitting shall be
provided for appliance connected by rigid metallic pipe. Such unions shall be accessible and located
within 6 feet of the appliance.



Where is gas piping permitted? - CORRECT ANSWER✅✅Gas piping may be installed in public corridors
in residential buildings that do not have floors below grade or in multi use buildings that have a
residential occupancy in accordance with the following, Gas piping shall be permitted to be installed
within a public corridor at the lowest level of the building or the lowest residential level of the building.
All gas valves located within the public corridor shall be accessible for maintenance and inspection. Gas
pressure within the public corridor piping shall not exceed 1/2 psi. The completed piping within the
public corridor is to be tested and proven tight at 10 psig for a minimum of 30 minutes. The public
corridor shall be ventilated in accordance with the New York City Mechanical Code. The pipe shall not be
installed in a return air plenum. Pipes must be welded.



How much must piping for other than dry gas conditions be sloped? - CORRECT ANSWER✅✅Not less
the 1/4 inch in 15 feet to prevent traps.



Hanger spacing for 3/4 inch and 1 inch gas pipe - CORRECT ANSWER✅✅8 feet



When is water permitted for testing? - CORRECT ANSWER✅✅Fresh water may be used the test
medium where the required test pressure exceeds 100 p.s.i.g.



When do need temporary restraints when testing? - CORRECT ANSWER✅✅Expansion joints shall be
provided with temporary restraints, if required, for the additional trust load under test.



What must each digital gauge used to measure pressure in the magnitude of 3 and higher read? -
CORRECT ANSWER✅✅The gauge shall have a minimum reading of 1/100 of a p.s.i.g.



Where pipe passes through an outside wall, this piping shall not be less than how many inches outside
of the buildings? - CORRECT ANSWER✅✅With conduit going through the wall, pipe shall not be less
than 4 inches outside the building and sleeve shall be at least 1 inch beyond the inner side of the wall.
Pipe shall be vented above grade to the outdoors and shall be installed so as to prevent the entrance of
water and insects.

, Threaded pipe may be used up to 4 inches at pressure no greater than? - CORRECT ANSWER✅✅1/2
p.s.i.g.



Gas piping going through the foundation wall of a building, shall be protected by? - CORRECT
ANSWER✅✅Encasing it in a protective sleeve.



Gas piping in solid floor shall be installed in a conduit of schedule 40 pipe. This conduit shall extend not
less than how many inches above the floor? - CORRECT ANSWER✅✅2 inches.



All exterior gas piping shall be elevated not less than how many inches above ground and roof surfaces?
- CORRECT ANSWER✅✅3 1/2 inches.



The untreated portion of gas piping outlets must extend at least how many inch through finished
ceilings and walls? - CORRECT ANSWER✅✅1 inch



Underground piping systems shall be installed a minimum depth of, how many inches below grade? -
CORRECT ANSWER✅✅24 inches



The unthreatened portion of gas piping outlets extending through floors or outdoor patios and slabs
must extend at least, how many inches above them? - CORRECT ANSWER✅✅2 inches



What gas is prohibited from being used for testing gas piping? - CORRECT ANSWER✅✅Oxygen



The testing duration for gas piping with distribution pressures over 1/2 p.s.I.g through 5 p.s.I.g is? -
CORRECT ANSWER✅✅50 p.s.I.g for a minimum of 30 minutes.



Supports for 1 inch gas piping shall be spaced no more than, how many feet apart? - CORRECT
ANSWER✅✅8 feet



The gas shut off valve shall be within how many feet of the appliance? - CORRECT ANSWER✅✅6 feet

Escuela, estudio y materia

Institución
NYC GAS CODE
Grado
NYC GAS CODE

Información del documento

Subido en
15 de abril de 2026
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$13.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STANGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
89
Miembro desde
1 año
Número de seguidores
1
Documentos
12011
Última venta
1 día hace
STAN-GRADES

EXCELLENCY IN ACADEMIC MATERIALS

3.4

14 reseñas

5
6
4
1
3
3
2
1
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes