MOSBY'S CT LATEST 2026 TEST PAPER QUESTIONS AND
SOLUTIONS RATED A+
✔✔retrospecting reconstruction - ✔✔reconstruction performed after the initial
prospective reconstruction.

✔✔ring artifact - ✔✔an incorrect ring of density on the reconstructed CT image resulting
from detector malfunction.

✔✔saline flush - ✔✔injection of a volume of normal saline solution immediately
following the bolus injection of a contrast agent; flushes any remaining contrast through
the automated injector tubing, improving the efficiency of contrast utilization.

✔✔scan delay - ✔✔the time between the initiation of contrast administration and CT
data acquisition.

✔✔scan field of view (SFOV) - ✔✔a parameter that controls the diameter of the circular
data acquisition field within the CT gantry as determined by the number of activated
detectors along the x-y axes. may also be referred to as the calibration field.

✔✔scinitllation - ✔✔the production of light energy by a CT detector material in response
to absorbed x-ray energy.

✔✔scout image - ✔✔digital survey radiograph acquired by the CT system for the
purpose of prescribing the cross-sectional acquisition. similar to a conventional
radiograph, it is produced by translating the patient through the gantry without tube and
detector rotation.

✔✔section interval - ✔✔the distance between the center of one CT section and the
center of the next adjacent section.

✔✔section width - ✔✔the dimension of a recontructed CT slice along the longitudinal
direction of acquisition (z-axis). commonly referred to as slice thickness.

✔✔signal - ✔✔electronic current emitted by the CT detector in responce to the
absorption and measurement of transmitted radiation.

✔✔signal-to-noise ratio (SNR) - ✔✔quantification of the amount of noise in a displayed
CT image. calculated as the standard deviation in the ROI measurement of a water
phantom image.

✔✔single-slice CT (SSCT) - ✔✔a CT system with a single row of detectors capable of
acquiring only one image section for each gantry rotation.

, ✔✔slice sensitivity profile (SSP) - ✔✔graph demonstrating the broadening of the section
width that is inherent to volumetric (helical) CT acquisition.

✔✔slip-ring - ✔✔the rotating assembly used to enable the passage of electrical signal
during continuous rotation of the helical CT system.

✔✔spatial frequency - ✔✔the waveform of signal that represents the varied objects
imaged by a CT system.

✔✔spatial resolution - ✔✔the ability of a CT imaging system to display fine details
separately. given in units of line pairs per centimeter (lp/cm)

✔✔step artifact - ✔✔the unwanted appearance of individual sections on a mulitplanar or
3D reformation image resulting in a loss of sharpness and detail.

✔✔stranding - ✔✔hazy increase in density of the fat surrounding an organ on CT
exams that usually indicates an inflammatory process.

✔✔surface rendering - ✔✔construction of a three-dimensional model of a specific tissue
type by limiting the displayed volumetric data on the basis of an attenuation threshold.
may also be reffered to as shaded surface display.

✔✔teleradiology - ✔✔the transmission of image data across networks from the imaging
facility to an offsite location for review and interpretation.

✔✔temporal resolution - ✔✔the ability of a CT system to freeze motion and provide an
image free of blurring.

✔✔total collimation - ✔✔the combined thickness of all of the sections that are
simultaneously acquired with each gantry rotation during MSCT acquisition.

✔✔triple rule-out - ✔✔comprehensive MSCT exam of the chest for cardiac and non-
cardiac pain. the single acquistion evaluates for coronary artery disease, aortic
aneurysm, and pulmonary embolism.

✔✔tube arcing - ✔✔short circuiting within the x-ray tube during data acquisition that
results in severe streak artifacts in the CT image.

✔✔uniform matrix array - ✔✔the type of MSCT detector array that utilized multiple
detectors in the longitudinal direction, each of the same length.

✔✔uniformity - ✔✔maintenance of relatively consistent CT values across the entire
image of an object of equal density.

Información del documento

Subido en
9 de abril de 2026
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BOARDWALK
3.5
(40)
Vendido
281
Seguidores
10
Artículos
32848
Última venta
1 día hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes