Where is the union located for a gas appliance? - CORRECT ANSWER✔✔-A union
| | | | | | | | | | | | |


fitting shall be provided for appliance connected by rigid metallic pipe. Such
| | | | | | | | | | | |


unions shall be accessible and located within 6 feet of the appliance.
| | | | | | | | | | |




Where is gas piping permitted? - CORRECT ANSWER✔✔-Gas piping may be
| | | | | | | | | | |


installed in public corridors in residential buildings that do not have floors below
| | | | | | | | | | | | |


grade or in multi use buildings that have a residential occupancy in accordance
| | | | | | | | | | | | |


with the following, Gas piping shall be permitted to be installed within a public
| | | | | | | | | | | | | |


corridor at the lowest level of the building or the lowest residential level of the
| | | | | | | | | | | | | | |


building. All gas valves located within the public corridor shall be accessible for
| | | | | | | | | | | | |


maintenance and inspection. Gas pressure within the public corridor piping shall
| | | | | | | | | | |


not exceed 1/2 psi. The completed piping within the public corridor is to be
| | | | | | | | | | | | | |


tested and proven tight at 10 psig for a minimum of 30 minutes. The public
| | | | | | | | | | | | | | |


corridor shall be ventilated in accordance with the New York City Mechanical
| | | | | | | | | | | |


Code. The pipe shall not be installed in a return air plenum. Pipes must be
| | | | | | | | | | | | | | |


welded.


How much must piping for other than dry gas conditions be sloped? - CORRECT
| | | | | | | | | | | | | |


ANSWER✔✔-Not less the 1/4 inch in 15 feet to prevent traps. | | | | | | | | | |




Hanger spacing for 3/4 inch and 1 inch gas pipe - CORRECT ANSWER✔✔-8 feet
| | | | | | | | | | | | |




When is water permitted for testing? - CORRECT ANSWER✔✔-Fresh water may
| | | | | | | | | | |


be used the test medium where the required test pressure exceeds 100 p.s.i.g.
| | | | | | | | | | | |

, When do need temporary restraints when testing? - CORRECT ANSWER✔✔-
| | | | | | | | |


Expansion joints shall be provided with temporary restraints, if required, for the
| | | | | | | | | | | |


additional trust load under test. | | | |




What must each digital gauge used to measure pressure in the magnitude of 3
| | | | | | | | | | | | | |


and higher read? - CORRECT ANSWER✔✔-The gauge shall have a minimum
| | | | | | | | | | |


reading of 1/100 of a p.s.i.g.
| | | | |




Where pipe passes through an outside wall, this piping shall not be less than how
| | | | | | | | | | | | | |


many inches outside of the buildings? - CORRECT ANSWER✔✔-With conduit
| | | | | | | | | | |


going through the wall, pipe shall not be less than 4 inches outside the building
| | | | | | | | | | | | | | |


and sleeve shall be at least 1 inch beyond the inner side of the wall. Pipe shall be
| | | | | | | | | | | | | | | | | |


vented above grade to the outdoors and shall be installed so as to prevent the
| | | | | | | | | | | | | | |


entrance of water and insects.
| | | |




Threaded pipe may be used up to 4 inches at pressure no greater than? -
| | | | | | | | | | | | | | |


CORRECT ANSWER✔✔-1/2 p.s.i.g. | |




Gas piping going through the foundation wall of a building, shall be protected by?
| | | | | | | | | | | | |


- CORRECT ANSWER✔✔-Encasing it in a protective sleeve.
| | | | | | | |




Gas piping in solid floor shall be installed in a conduit of schedule 40 pipe. This
| | | | | | | | | | | | | | | |


conduit shall extend not less than how many inches above the floor? - CORRECT
| | | | | | | | | | | | | |


ANSWER✔✔-2 inches. |

Escuela, estudio y materia

Institución
Nyc gas code
Grado
Nyc gas code

Información del documento

Subido en
8 de abril de 2026
Número de páginas
12
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectphilip West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
267
Miembro desde
2 año
Número de seguidores
6
Documentos
24658
Última venta
16 horas hace
WELCOME TO LECTPHILIP, A PLACE WHERE WE UNLOCK YOUR ACADEMIC OPPORTUNITIES

On this page, you find all documents, package deals and flashcards offered by seller lectphilip

4.0

42 reseñas

5
21
4
8
3
9
2
2
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes