Any person found performing the duties of a license and holding an
expired license, shall be subject to what type of penalty? -
ANSWERS-They shall be subject to a min penalty of $500 up to a
max of $5,000 per day.


What are some advantages of steam heating systems? - ANSWERS-
The height of the building does not affect the steam, the steam can be
used to operate equipment, and it can carry large amounts of energy
over long distances.


What is the Act (Law) that establishes the licensing requirements in
the state of NJ for Stationary, Power Engineers, Refrigeration
Engineers and Boiler Operators? - ANSWERS-N.J.S.A 34:7-1


Which is the act that a Mechanical Inspection Bureau exists in New
Jersey? - ANSWERS-The New Jersey Statute Annotated (NJSA)
34:1-38.1


What is the range of capacity that a High Pressure Boiler Operator
can be the Chief Engineer and work as Shift Engineer (stand watch)
based on the 12:90 Boiler, Pressure Vessel and Refrigeration rules? -
ANSWERS-Can act as Chief Engineer and stand watch of a plant
with a minimum capacity of 100 HP and up to 500 HP

,The various license classifications and grades for operating high
pressure boilers are found in the NJAC reference section listed as: -
ANSWERS-Table 3.4


According to the codes and standards adopted and incorporated by
reference of the boiler pressure vessels and refrigeration regulations,
welded repairs and any alternations made to the boilers must comply
with what? - ANSWERS-The original Code of construction when it
was built


T or F: according to the regulation, a licensed operator on watch shall
give constant attention and remain within sight and natural sound in
both HP and LP boilers. - ANSWERS-False


To be eligible for HP boiler operator in charge examination, what is
the duration of time indicated in the regulations that an applicant must
have for an intensive training program established by the Chief
Engineer and approved by the Bureau of Boiler Pressure Vessel
Compliance - ANSWERS-For a period of no less than 6 weekst


Which formula would you use to calculate the Btu/lb heat content of
fuel oil? - ANSWERS-17,687 + 57.7 x API @ 60 degrees F


By ASME code, water column connections must be a minimum of: -
ANSWERS-1 inch


What is the formula for boiler horsepower? - ANSWERS-Steaming
Capacity ÷ 34.5

, What is the formula used to convert Kw to HP? - ANSWERS-Kw x
1.341 = HP


What is the formula used to convert BTU's to HP? - ANSWERS-BTU
÷ 33,475 = HP


What is the formula for heating surface? - ANSWERS-D x 3.14 x L x
N / 144


Why do we use economizers on boilers? - ANSWERS-To heat the
feedwater


The examining board of the mechanical inspection bureau of boiler
and pressure vessel compliance may consider an applicant experience
of an equivalent amount for grade or classification from some other
jurisdictional authority (state or federal) - ANSWERS-False


What has a smaller flow rate: gate or globe valve? - ANSWERS-
Globe valve


What would produce the larger head loss: gate valve or globe valve? -
ANSWERS-Globe valve


What is stated in N.J.A.C 12:90? - ANSWERS-It's the regulation
corresponding to boiler, pressure vessels & refrigeration systems in
NJ

Información del documento

Subido en
29 de marzo de 2026
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Teacher101
4.6
(276)
Vendido
500
Seguidores
74
Artículos
11075
Última venta
22 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes