MASTER ELECTRICIAN EXAM QUESTIONS WITH GUARANTEED ANSWERS [GUARANTEED ANSWERS]

Document preview thumbnail
Vista previa 3 fuera de 20 páginas

MASTER ELECTRICIAN EXAM QUESTIONS WITH GUARANTEED ANSWERS [GUARANTEED ANSWERS]

Vista previa del contenido

MASTER ELECTRICIAN EXAM QUESTIONS
WITH GUARANTEED ANSWERS
[GUARANTEED ANSWERS]
branch circuit - Correct Answers -That portion of a wiring system extending beyond the final
overcurrent device is called the:



Calculated load - Correct Answers -The final sum of the computed loads, based on the minimum
code requirements, is the



Resistance - Correct Answers -As compared to #10, a #8 wire of the same Iength has less:



0.001 inch - Correct Answers -One circular mil is the area of a circle whose diameter is:



1,000,000 cm - Correct Answers -A round bus-bar one inch in diameter, has a circular mil area
of:



four times as great - Correct Answers -A copper wire with twice the diameter of another wire
has a current carrying capacity:



10.4 - Correct Answers -The specific resistance of copper wire @ 20° C in ohms per circular mil
ft. is



permit current to flow - Correct Answers -Conductance of an electric circuit is that property that
will:



1O ohms - Correct Answers -The equivalent value of 0.1 mho is



directly proportional to its length - Correct Answers -The resistance of copper wire is:

,Feeder - Correct Answers -The portion of a wiring system between a point of distribution and
the branch circuit overcurrent device is



locking - Correct Answers -GFCI protection at a carnival is not required for equipment at circuit if
the receptacle is of the ____________type



not less than 1 1/4 in. from - Correct Answers -Where cables or nonmetallic raceways are
installed through bored.holes in joists, rafters, or wood members;holes shall be bored so that
the edge of the hole is the nearest edge -of the wood member.



located on a balcony accessible only to qualified persons

located in a room only accessible to

qualified persons

elevated 8 ft or more above floor or other working surface - Correct Answers -To guard live parts
over 50V but less than 600V, equipment is permitted to be



12Ft - Correct Answers -Overhead feeder conductors shall have a minimum __________ vertical
clearance over residential property and driveways, as well as those commercial areas not
subject to truck traffic, where the voltage is limited to 300 volts-to-ground.



36 inches - Correct Answers -Where rear access is required to work on de-energized parts on
the back of enclosed equipment, a minimum working space of horizontally shall be provided.



50' - Correct Answers -What is the maximum run length of a 18AWG fixture wire that is tapped
on to a 20 amp branch circuit?



power supply failure - Correct Answers -When the service disconnecting means is a power-
operated switch or circuit breaker, it shall be able to be opened by hand in the event of a

, 2 in of concrete - Correct Answers -Conductors are considered outside a buildings when they
are buried under not less than



8 - Correct Answers -In straight pull, the length of the box shall not be less than. ____times the
trade size of the largest raceway.



18" - Correct Answers -At least one receptacle outlet shall be installed within of the top of a
show window for each 12 linear feet measured horizontally across its length



1000A - Correct Answers -Ground-fault protection of equipment shall be provided fro solidly
grounded wye electrical services of more than 150 volts-to-ground, but not exceeding 600V
phase-to..phase for each service disconnecting means rated



18" - Correct Answers -Receptacle outlets in floors shall not be counted as part of the required

number of receptacle outlets unless located within ______ of the wall



50V - Correct Answers -Exposed live parts of motors and controllers operating at or more
between terminals shall be guarded against accidental contact by enclosure or by location



5' - Correct Answers -Lighting track shall not be installed less than______ above the finished
floor except' where protected from physical damage or where the track operates at less than 30
V rms, open-circuit voltage



4 - Correct Answers -Each general care area patient bed location shall be provided with a
minimum of_______receptacles, which can be single, duplex, or a combination with each
duplex counting as two receptacles



Combination Range hood/ Microwave

Información del documento

Subido en
26 de marzo de 2026
Número de páginas
20
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.89

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
146
Última venta
-


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes