Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 16 páginas
Examen

EPA 608 Type III Exam 2026–2027 – Complete Questions and Verified Answers

Document preview thumbnail
Vista previa 3 fuera de 16 páginas

This document contains the EPA 608 Type III certification exam, including all questions and 100% verified correct answers. It covers advanced topics such as high-pressure refrigerant systems, leak detection, recovery procedures, safety protocols, and environmental regulations required for certification. The material reflects the latest 2025 version and provides expert-verified solutions, ensuring thorough preparation and a guaranteed pass.

Vista previa del contenido

1|Pag e


EPA 608 TYPE 3 EXAM|| 2026-2027 QUESTIONS
AND 100% CORRECT ANSWERS ALREADY
GRADED A+|| LATEST AND FULLY COVERED
VERSION 2025 WITH EXPERT VERIFIED
SOLUTIONS|| ASSURED PASS!!!
On low pressure chillers, moisture typically enters the refrigerant system through
air leaks from areas with gaskets or fittings


The maximum test pressure for leak testing a low pressure centrifugal is: 10 psig




Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-
11 chiller
...


A hydrostatic tube test kit is used to:
determine if a tube leaks




Commercial and industrial process refrigeration systems must be repaired when the
leak rate exceeds of the charge per year.
35%




Refrigerant recovery typically start,
with liquid recovery it is faster.

,2|Pag e




A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: 15
psig




According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1
mm Hg to a level above during a standing vacuum test, the system should be
checked for leaks.
2.5 mm Hg




The primary water source for a recovery unit condensing coil is .
local municipal water supply




When recharging a refrigeration system with R-11, what vaporpressure is
necessary in the shells before changing with liquid?
16.9" Hg vacuum




After recovering the liquid refrigerant you must:
recover the vapor refrigerant

, 3|Pag e


According to the EPA there is approximately refrigerant vapor left in an
average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been
removed.
100 pounds




Charging refrigerant liquid into a refrigeration system when it is under a 29 inch
Hg vacuum can cause the:
system water to freeze




A system does not have to be evacuated all the way to the required level when:
leaks in the appliance make evacuation to the prescribed level unattainable Which
of the following repairs would ALWAYS be considered "major" under EPA's
replacement of evaporator coil




Under EPA's regulation's is used to pressurize a low pressure chiller for the
purpose of opening the system for a non-major repair?
warming the refrigerant




If you are using a recovery machine manufactured AFTER 11-15-93 you must
evacuate an low pressure appliance to before making a major repair.
25 mm of Hg absolute




After reaching the required recovery vacuum on a chiller, you should

Información del documento

Subido en
25 de marzo de 2026
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TopGradeSolutions
4.9
(174)
Vendido
108
Seguidores
9
Artículos
13450
Última venta
23 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes