Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 34 páginas
Examen

ARE 5.0 PDD BALLAST PRACTICE QUESTIONS AND CORRECT ANSWERS

Document preview thumbnail
Vista previa 4 fuera de 34 páginas

ARE 5.0 PDD BALLAST PRACTICE QUESTIONS AND CORRECT ANSWERS

Vista previa del contenido

Which of the following statements about tempered glass (TG) is true?


A- TG is required in entry doors.
B- TG is not a requirement for sidelights with sills below 18".
C- TG is not a requirement for glazing within 1' of doors.
D- TG is required in glass within 36" of doors.


Give this one a try later!


A- TG is required in entry doors.




4. Which statement concerning fire-rated door assemblies is correct?


A- Hinges must always be the ball bearing type.
B- Under some circumstances a closer is not needed.
C- Labeling is required for the door only.
D- The maximum width is 3'-0"

,Give this one a try later!


A- Hinges must always be the ball bearing type.




Which of the following is a requirement of the NFPA 10 (Portable Fire Extinguishers)?
(Choose 3)


A- FE Cabinets must have a vision panel or be clearly marked with a sign.
B- FE must be tested regularly and have an approved label.
C- FE Cabinets may not protrude into the hallway more than 4".
D- When fire extinguishers are required, no occupant may be more than 75' from a fire
extinguisher.
E- Fire extinguishers must be mounted at 48" above the finish floor.
F- Cabinets must be locked at all times.


Give this one a try later!


A- FE Cabinets must have a vision panel or be clearly marked with a sign.
B- FE must be tested regularly and have an approved label.
D- When fire extinguishers are required, no occupant may be more than 75'
from a fire extinguisher.




An existing partition separating two rooms is determined to be insufficient for
reducing sound transmission. The partition consists of 4" metal studs spaced 24" o/c
with a single layer of 5/8" gyp on ea. side. There are no penetrations in the partition.
To improve transmission loss of the partition in the most economical way, which of the
following modifications should the architect reccommend?
A- Add resilient channels to one side of the wall and attach a single later of gypsum
board to the channels. Glue additional layer of gypsum board to other side.
B- Add sound-absorbing panels to the noisy side of the partition, and add an
additional layer of gypsum board to the opposite side.
C- remove one layer of gyp, install batt insulation and replace the wall finish with a
sound-deadening board and a finish layer of gypsum board.

,D- Cover one side of the partition with an additional layer of gypsum board and add
two additional layers of gypsum board to the other side.


Give this one a try later!


A- Add resilient channels to one side of the wall and attach a single later of
gypsum board to the channels. Glue additional layer of gypsum board to
other side.




According to ACI 318, a cantilevered reinforced concrete slab spanning 10' ft needs to
have a minimum thickness of:


A- 6"
B- 12"
C- 20"
D- 24"


Give this one a try later!


B- 12"




Which of the following devices would best control entry to a secure laboratory?


A- Card Reader
B- Central Station Alarm
C- Photoelectric Cell
D- Ultrasonic Detector


Give this one a try later!

, A- Card Reader




The IBC requires that a certain amount of accidental torsion be considered even
when a building is symmetrical. Why? (Choose 4)


A- To allow for nonuniform vertical loading.
B- To allow for asymmetrical floor openings.
C- To reduce the effect of overturning moments.
D- To reduce drift.
E- To allow for eccentricity in rigidity due to non-structural elements and seismic
ground motion.
F- To allow for the fact that positions of loads in an occupied building cannot exactly
be determined.


Give this one a try later!


A- To allow for nonuniform vertical loading.
B- To allow for asymmetrical floor openings.
E- To allow for eccentricity in rigidity due to non-structural elements and
seismic ground motion.
F- To allow for the fact that positions of loads in an occupied building
cannot exactly be determined.




A design for a rest station at an amusement park includes a group of six family
restrooms, each containing a toilet, lav, and changing table. At least ________ of these
restrooms must be accessible.


Give this one a try later!


3

Información del documento

Subido en
22 de marzo de 2026
Número de páginas
34
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$10.50

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
10
Seguidores
0
Artículos
4627
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes