Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 7 páginas
Examen

Fluoroscopy Quiz with correct answers 100% 2026

Document preview thumbnail
Vista previa 2 fuera de 7 páginas

Fluoroscopy Quiz with correct answers 100% 2026 True or False? Fluoroscopy uses a continuous beam of x-rays to create images of the movement of internal structures that can be viewed on a monitor. - Correct Answer True True or False? Fluoroscopy allows imaging of anatomy in motion, or dynamic imaging. - Correct Answer True True or False? Releasing the pressure applied to the deadman switch will terminate the radiation exposure during fluoroscopy. - Correct Answer True True or False? Image intensification is the process that the exits radiation from the anatomic area of interest interacts with the input phosphor for conversion to visible light, which are converted to electrons by a photocathode, then focused by electrostatic focusing lenses, and accelerated toward an anode to strike the output phosphor. - Correct Answer True True or False? X-rays exiting the patient interact with the image intensifier to produce light photons which are then converted to electrons and finally back to light energy. - Correct Answer True True or False? The output phosphor is coated with light-emitting crystals to absorb electrons and emit light. - Correct Answer True True or False? The input phosphor absorbs x-rays and emits light. - Correct Answer True True or False? The photocathode absorbs light and converts light to electrons. - Correct Answer True True or False? The input phosphor is considerably larger than the output phosphor. - Correct Answer True True or False? The image at the output phosphor is brighter in part because it is significantly smaller than the same image at the input phosphor. - Correct Answer True True or False? The conversion factor, another descriptor of the overall ability of an image intensifier to create a brighter image, is measured in cd/m2/mR/s. - Correct Answer True True or False? Brightness gain: minification gain x flux gain. - Correct Answer True True or False? The conversion factor is a newer term for brightness gain and is typically about 1% of the brightness gain value. - Correct Answer True True or False? ABC, or automatic brightness control maintains the brightness and contrast of the fluoroscopic image during the procedure. - Correct Answer True True or False? Magnification of the fluoroscopic image occurs when the electrostatic lenses have more voltage applied, creating a more negative charge. - Correct Answer True True or False? The magnification factor during fluoroscopic is equal to the full size input phosphor divided by the selected input phosphor. - Correct Answer True True or False? Using the magnification mode improves spatial resolution of the fluoroscopic image. - Correct Answer True True or False? Additional x-ray photons must leave the patient and be absorbed by the image intensifier when magnification mode is used. resulting in increased patient dose.*** - Correct Answer True True or False? Typical fluoroscopic systems have spatial resolution capabilities in the range of 4 to 6 Lp/mm. - Correct Answer True True or False? Shape distortion during fluoroscopy is the result of the curved shape of the input phosphor and photocathode. - Correct Answer True True or False? Pincushion appearance is the distortion of the fluoroscopic image that appears as unequal magnification. - Correct Answer True True or False?

Vista previa del contenido

True or False?

Fluoroscopy uses a continuous beam of x-rays to create images of the movement of internal structures
that can be viewed on a monitor. - Correct Answer True



True or False?

Fluoroscopy allows imaging of anatomy in motion, or dynamic imaging. - Correct Answer True



True or False?

Releasing the pressure applied to the deadman switch will terminate the radiation exposure during
fluoroscopy. - Correct Answer True



True or False?

Image intensification is the process that the exits radiation from the anatomic area of interest interacts
with the input phosphor for conversion to visible light, which are converted to electrons by a
photocathode, then focused by electrostatic focusing lenses, and accelerated toward an anode to strike
the output phosphor. - Correct Answer True



True or False?

X-rays exiting the patient interact with the image intensifier to produce light photons which are then
converted to electrons and finally back to light energy. - Correct Answer True



True or False?

The output phosphor is coated with light-emitting crystals to absorb electrons and emit light. - Correct
Answer True



True or False?

The input phosphor absorbs x-rays and emits light. - Correct Answer True



True or False?

, The photocathode absorbs light and converts light to electrons. - Correct Answer True



True or False?

The input phosphor is considerably larger than the output phosphor. - Correct Answer True



True or False?

The image at the output phosphor is brighter in part because it is significantly smaller than the same
image at the input phosphor. - Correct Answer True



True or False?

The conversion factor, another descriptor of the overall ability of an image intensifier to create a
brighter image, is measured in cd/m2/mR/s. - Correct Answer True



True or False?

Brightness gain: minification gain x flux gain. - Correct Answer True



True or False?

The conversion factor is a newer term for brightness gain and is typically about 1% of the brightness gain
value. - Correct Answer True



True or False?

ABC, or automatic brightness control maintains the brightness and contrast of the fluoroscopic image
during the procedure. - Correct Answer True



True or False?

Magnification of the fluoroscopic image occurs when the electrostatic lenses have more voltage applied,
creating a more negative charge. - Correct Answer True



True or False?

The magnification factor during fluoroscopic is equal to the full size input phosphor divided by the
selected input phosphor. - Correct Answer True

Información del documento

Subido en
22 de marzo de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$9.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EXAMSSITE
3.0
(1)
Vendido
19
Seguidores
3
Artículos
2314
Última venta
2 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes