Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

ASCP CG CERTIFICATION PRACTICE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) | ASSURED SUCCESS|| LATEST UPDATE 2027

Puntuación
-
Vendido
-
Páginas
21
Grado
A+
Subido en
20-03-2026
Escrito en
2025/2026

ASCP CG CERTIFICATION PRACTICE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) | ASSURED SUCCESS|| LATEST UPDATE 2027 What test(s) should be ordered on a newborn with suspected Prader-Willi syndrome? - ANSWER -High resolution banding and FISH for the Prader-Willi locus on 15q11.2 When capturing a metaphase, a tech cannot get the met into focus, what is the most likely cause? - ANSWER -The camera is not parfocal (in focus with the microscpe objectives) with the microscope Unstained chromosome preparation should be viewed using which scope? - ANSWER -Phase contrast condenser The minimum band level necessary to detect prader-willi syndrome is? - ANSWER -550 at the lowest 15q11.2 is visible at that level See CAP regulation CYG.42300 A regulatory inspecter requests a copy of a lab patient's record for his inspection files, the tech should: - ANSWER -Deny the inspector a copy of the record See HIPAA compliance policy According to CAP regulations, what is the minimum band level for consitutional specimens? - ANSWER -400 The suggested level for most constitutional specimen is 550, but 400 is the lowest acceptible level See CAP regulation CYG.42200 Placental tissue is submitted for chromosome analysis, to optimize the liklihood of obtaining fetal cells, where should the tech select tissue from? - ANSWER -The fetal side of the spcimen (when possible to be identified from the decidua) In a compound light microscope, the aperature stop affects resolution and contrast by: - ANSWER -Changing the angle of the cone of light inside the objective What is the correct nomenclature to describe a hematologic disorder with trisomy 21 in 6 cells and 14 cells that are normal? - ANSWER 47,XY,+21?c[6]/46,XY[14] ?c -- indicates questioning whether the trisomy is constitutional or not as it was seen in only 6 cells The G-light bands produced by routine GTG banding represent: - ANSWER -The active regions of the chromosome aka euchromatin -- gene-rich and GC rich DNA, early replicating Which of the following is not assocated with a microdeletion? 1. Prader-Willi 2. DiGeorge 3. Rubinstein-Taybi 4. Langer-Giedion - ANSWER -3. Rubinstein-Taybi Associated with an autosomal dominant mutation in the CREB or CREBBP gene(s) Rarely assocated with a deletion in 16p13.3 (12% of cases, not the predominant cause, detected by FISH) Presents as facial dysmorphism, broad thumbs, broad big toes, and growth and mental retardation The dark bands produced by routune GTG banding represent: - ANSWER -AT rich regions of the chromosome aka heterpchromatin, and gene-poor chromatin, late replicating DNA If GTG banded chromosomes appear ghost-like with little visible banding, one should alter banding prep by: - ANSWER -Decreasing trypsin time (chewed out and non-distinct) If 50 out of 200 interphase nuclei have 3 signals in a prenatal aneusomy FISH analysis for chromosome 18, the results are: - ANSWER -Consistent with trisomy 18 or a structural anomaly of chromosome 18 If the same hybridization incubator is used for several different probe strategies, the stringency for each probe can be adjusted by: - ANSWER -adjusting the formamide and salt concentrations Optimal (best) banding quality is achieved for each patient sample by banding: - ANSWER -one trial slide per patient to ensure BEST quality In fluorescent microscopy, the exciter and barrier filters used depend on ___ ? - ANSWER -Stain - because the wavelength for emission can vary per type of fluorescent stain used (i.e. DAPI) What is a possible reason a metaphase cannot be located when switching from the 40x lens to the 100x oil lens? - ANSWER -The 100x objective is slightly unscrewed (can occur when cleaning the scope) What is an action a technologist can take to reduce the risk of repetitve motion injuries when doing analysis on a computer? - ANSWER -Supporting the arm that moves the mouse, Standing and moving around often, and alternating hands while operating the computer mouse

Mostrar más Leer menos
Institución
ASCP CG CERTIFICATION
Grado
ASCP CG CERTIFICATION

Vista previa del contenido

ASCP CG CERTIFICATION PRACTICE QUESTIONS
AND CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) | ASSURED SUCCESS|| LATEST UPDATE
2027
What test(s) should be ordered on a newborn with suspected Prader-Willi
syndrome? - ANSWER -High resolution banding and FISH for the Prader-Willi
locus on 15q11.2

When capturing a metaphase, a tech cannot get the met into focus, what is the
most likely cause? - ANSWER -The camera is not parfocal (in focus with the
microscpe objectives) with the microscope

Unstained chromosome preparation should be viewed using which scope? -
ANSWER -Phase contrast condenser

The minimum band level necessary to detect prader-willi syndrome is? -
ANSWER -550 at the lowest

15q11.2 is visible at that level
See CAP regulation CYG.42300

A regulatory inspecter requests a copy of a lab patient's record for his inspection
files, the tech should: - ANSWER -Deny the inspector a copy of the record

See HIPAA compliance policy

According to CAP regulations, what is the minimum band level for consitutional
specimens? - ANSWER -400

The suggested level for most constitutional specimen is 550, but 400 is the lowest
acceptible level
See CAP regulation CYG.42200

, Placental tissue is submitted for chromosome analysis, to optimize the liklihood of
obtaining fetal cells, where should the tech select tissue from? - ANSWER -The
fetal side of the spcimen (when possible to be identified from the decidua)

In a compound light microscope, the aperature stop affects resolution and contrast
by: - ANSWER -Changing the angle of the cone of light inside the objective

What is the correct nomenclature to describe a hematologic disorder with trisomy
21 in 6 cells and 14 cells that are normal? - ANSWER -
47,XY,+21?c[6]/46,XY[14]

?c -- indicates questioning whether the trisomy is constitutional or not as it was
seen in only 6 cells

The G-light bands produced by routine GTG banding represent: - ANSWER -The
active regions of the chromosome

aka euchromatin -- gene-rich and GC rich DNA, early replicating

Which of the following is not assocated with a microdeletion?

1. Prader-Willi
2. DiGeorge
3. Rubinstein-Taybi
4. Langer-Giedion - ANSWER -3. Rubinstein-Taybi

Associated with an autosomal dominant mutation in the CREB or CREBBP
gene(s)
Rarely assocated with a deletion in 16p13.3 (12% of cases, not the predominant
cause, detected by FISH)

Presents as facial dysmorphism, broad thumbs, broad big toes, and growth and
mental retardation

, The dark bands produced by routune GTG banding represent: - ANSWER -AT-
rich regions of the chromosome

aka heterpchromatin, and gene-poor chromatin, late replicating DNA

If GTG banded chromosomes appear ghost-like with little visible banding, one
should alter banding prep by: - ANSWER -Decreasing trypsin time (chewed out
and non-distinct)

If 50 out of 200 interphase nuclei have 3 signals in a prenatal aneusomy FISH
analysis for chromosome 18, the results are: - ANSWER -Consistent with trisomy
18 or a structural anomaly of chromosome 18

If the same hybridization incubator is used for several different probe strategies,
the stringency for each probe can be adjusted by: - ANSWER -adjusting the
formamide and salt concentrations

Optimal (best) banding quality is achieved for each patient sample by banding: -
ANSWER -one trial slide per patient to ensure BEST quality

In fluorescent microscopy, the exciter and barrier filters used depend on ___ ? -
ANSWER -Stain - because the wavelength for emission can vary per type of
fluorescent stain used (i.e. DAPI)

What is a possible reason a metaphase cannot be located when switching from the
40x lens to the 100x oil lens? - ANSWER -The 100x objective is slightly
unscrewed (can occur when cleaning the scope)

What is an action a technologist can take to reduce the risk of repetitve motion
injuries when doing analysis on a computer? - ANSWER -Supporting the arm that
moves the mouse,
Standing and moving around often, and
alternating hands while operating the computer mouse

Escuela, estudio y materia

Institución
ASCP CG CERTIFICATION
Grado
ASCP CG CERTIFICATION

Información del documento

Subido en
20 de marzo de 2026
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheExamMaestro Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
149
Miembro desde
2 año
Número de seguidores
5
Documentos
3564
Última venta
1 semana hace
STA

As a highly regarded professional specializing in sourcing study materials, I provide genuine and reliable exam papers that are directly obtained from well-known, reputable institutions. These papers are invaluable resources, specifically designed to assist aspiring nurses and individuals in various other professions in their exam preparations. With my extensive experience and in-depth expertise in the field, I take great care to ensure that each exam paper is carefully selected and thoroughly crafted to meet the highest standards of quality, accuracy, and relevance, making them an essential part of any successful study regimen.

Lee mas Leer menos
3.6

18 reseñas

5
9
4
2
3
2
2
0
1
5

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes