Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 137 páginas
Examen

3rd Class Power Engineering - B1 - Questions and Answers.

Document preview thumbnail
Vista previa 4 fuera de 137 páginas

3rd Class Power Engineering - B1 - Questions and Answers.

Vista previa del contenido

3rd Class Power Engineering - B1 - Questions and Answers
Question 1
High Temperature Plastic insulation?

Correct Answer
- Comes in a mouldable cement form and is used to fill gaps in refractory/block insulation
- Temperature limit of 1050 deg.C



Question 2
Code Requirements for Pressure Gauges?
Correct Answer
- Every boiler must have a pressure gauge attached to the steam space, water column, or steam connection
- Gauges must be fitted with a shut off valve or cock
- Gauges should contain siphons to prevent steam from entering the gauge
- Each boiler shall be provided with a connection of at least NPS 1/4 (6mm) pipe size so an inspector can connect his test
gauge for the accuracy of the boilers gauge
- The gauge must be capable of measuring no less than 1.5 times the pressure at which the boiler safety valve has set




Page 1 of 137

,Question 3
Method of support for Furnace Walls?
Correct Answer
- Tubes are welded into the top headers
- Buckstays are used to give furnace walls lateral support



Question 4
Plate thickness range for drums and shells?
Correct Answer
6.4 mm to 250 mm



Question 5
Gas Bypass Systems?
Correct Answer
- Separates the convection section in the furnace into 2 or more parallel gas passes, with control dampers installed for
each pass
- At full load, each set of louvres to each pass is open 100%
- Spray desuperheating is usually used up to about 40% of full load
- At lower loads, more gas os passed through the reheat section and less through the superheat section, which allows the
reheat temperature to remain constant




Page 2 of 137

,Question 6
Multiple Retort Underfeed Stoker Furnaces?
Correct Answer
- Several retorts which are inclined from the front of the furnace toward the rear of the furnace
- Each retort is supplied with coal by a ram and the coal moves along the inclined retorts to the rear of the furnace where
the ash is discharged



Question 7
2 thing to check in preparation to Drying out Refractory?

Correct Answer
- Ensure that the low water level shutdown is ON and make sure the drum vent is open when filling
- Ensure the gauge glass is in service



Question 8
Axial Staged Return Flow, Low NOx burner?
Correct Answer
- Combustion air is fed in several stages which separates the primary and secondary air to slow combustion
- Recycles flue gas back to the burner outlet




Page 3 of 137

, Question 9
The ASME and ASTM entail what rules around boiler tubing?
Correct Answer
- All pressure tubes are subjected to a hydrostatic test or NDT testing after manufacture
- Maximum tube size in boilers cannot exceed 127 mm



Question 10
How does the operating pressure of the boiler affect Natural Circulation?
Correct Answer
- As boiler pressure increases, the density of steam increases
- The higher the pressure, the less difference in density there is between downcomer water and riser water/steam
mixture, this DECREASES circulation
- Natural Circulation boilers are limited to pressures below 21 000 kPa



Question 11
Sootblowing around Reheaters?
Correct Answer
- Blowing soot around the wall tubes of a reheater will decrease reheat temperature
- Blowing the reheater tubes themselves will increase reheat temperature




Page 4 of 137

Información del documento

Subido en
6 de marzo de 2026
Número de páginas
137
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorExpert
3.7
(76)
Vendido
575
Seguidores
314
Artículos
10430
Última venta
22 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes