Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

EPA 609 TECHNICIAN CERTIFICATION TEST 2026/2027 BANK 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS / ALL EXAM QUESTIONS AND VERIFIED ANSWERS |ALREADY GRADED A+|

Puntuación
-
Vendido
-
Páginas
71
Grado
A+
Subido en
28-02-2026
Escrito en
2025/2026

EPA 609 TECHNICIAN CERTIFICATION TEST 2026/2027 BANK 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS / ALL EXAM QUESTIONS AND VERIFIED ANSWERS |ALREADY GRADED A+|

Institución
EPA 609 TECHNICIAN CERTIFICATION
Grado
EPA 609 TECHNICIAN CERTIFICATION

Vista previa del contenido

Page |1


EPA 609 TECHNICIAN CERTIFICATION TEST 2026/2027
BANK 400 QUESTIONS WITH DETAILED VERIFIED
ANSWERS / ALL EXAM QUESTIONS AND VERIFIED
ANSWERS |ALREADY GRADED A+|



Certification for Refrigerant Recovery - ANSWER-Anyone who
recovers refrigerant during the maintenance, service or repair of
small appliances must be certified as either a Universal
Technician or a Type I Technician.



EPA Refrigerant Capture Requirement - ANSWER-EPA
regulations require the capture of at least 80% of the refrigerant
from a small appliance with a non-operating compressor if the
technician is using either type of recovery unit.



Passive System-Dependent Recovery Method - ANSWER-When
using a passive system-dependent recovery method on an
appliance with an operating compressor, you should run the
(appliance's) compressor and recover the refrigerant from the
high side.

, Page |2


Passive System-Dependent Recovery Device - ANSWER-A
passive system-dependent recovery device for small appliances
captures refrigerant in a non-pressurized container.



Sale of CFC and HCFC Refrigerants - ANSWER-The sale of CFC
and HCFC refrigerants is restricted to technicians who are EPA
certified in refrigerant recovery.



EPA-Approved Recovery Devices - ANSWER-none of the above
refrigerants should be recovered with current EPA-approved
recovery devices.



Leak Repair Requirement for Small Appliances - ANSWER-it is
not mandatory to repair the leak but do so whenever.



Permissible Use of Passive Recovery Device - ANSWER-it is
permissible to use a passive recovery device for refrigerant
recovery on a domestic refrigerator.

, Page |3


Schraeder Valves Inspection - ANSWER-it is 'critical' to inspect
the schraeder valve core for bends and breakage.



Damaged Schraeder Valve Core - ANSWER-replace any
damaged schraeder valve core to prevent leakage.



Schraeder Ports Capping - ANSWER-cap the schraeder ports to
prevent accidental depression of the valve core.



Decomposition of R-12 or R-22 - ANSWER-If R-12 or R-22 are
exposed to high temperatures, these refrigerants can decompose
to form hydrochloric and hydrofluoric acids.



Refrigerant venting from charging cylinder - ANSWER-must be
recovered.



Standard vacuum pump for evacuation - ANSWER-can never be
used as a recovery device in combination with a pressurized
container.

, Page |4


EPA Section 608 certification renewal - ANSWER-must be
renewed every 10 years.



Shipping used refrigerant requirements - ANSWER-all of the
above.



Direct service drop-in substitute for R-12 - ANSWER-none of the
above.



System pressure before recovery procedure - ANSWER-0 psig.



EPA definition of a small appliance - ANSWER-Both 'a' and 'b'.



Extra measures for trapped refrigerant release - ANSWER-
passive system-dependent recovery devices on a small
appliances with a non-operating compressor.



Exception to self-contained recovery machine rule - ANSWER-
small appliances.

Escuela, estudio y materia

Institución
EPA 609 TECHNICIAN CERTIFICATION
Grado
EPA 609 TECHNICIAN CERTIFICATION

Información del documento

Subido en
28 de febrero de 2026
Número de páginas
71
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$25.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursingPal Chamberlain College of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
18
Miembro desde
1 año
Número de seguidores
1
Documentos
1384
Última venta
1 semana hace
Nursing Papers Store

Looking for top-quality nursing exam resources? My comprehensive study materials on Stuvia are designed to help you succeed! With detailed explanations, practice questions, and expert insights, these exams are tailored to boost your understanding and performance. Invest in your future—purchase now and ace your nursing exams with confidence!

4.8

4 reseñas

5
3
4
1
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes