Type ____ is multiconductor cable identified for use as underground service entrance cable. - (ANSWER)Type
USE cable


Knife switch rated for more than 1200 Amps at 250Volts or less - (ANSWER)Can be used only as isolating
switch, shall not be opened under load


Track lighting with outlets in a bathroom is not allowed because ? - (ANSWER)Track lighting has receptacle


Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an
on premise fuel supply sufficient for not less than ____ hours full demand operation of the system -
(ANSWER)6 hours


Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be
permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - (ANSWER)30
Amps


Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - (ANSWER)Both ends


GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. -
(ANSWER)Locking


The maximum voltage drop from service point to the last over-current device in a dwelling unit? -
(ANSWER)4%


Which of the following statements best describe the grounding requirement for central vacuum outlet -
(ANSWER)Accessible non current carrying metal parts are required to be connected to an equipment grounding
conductor.




Page 1 of 17

,In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two
branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system
- (ANSWER)Are permitted


Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or
similar areas - (ANSWER)Do not include


The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. -
(ANSWER)Examined or treated


Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____
duplex receptacles - (ANSWER)Single or two


A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24
hour basis of ____ or more patients - (ANSWER)Four


Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways
shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic
equipment - (ANSWER)Listed fitting


Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating
not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation
temperature - (ANSWER)3 inches


Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not
exceeding ____ ft. - (ANSWER)6 ft


Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a
____ that shall be visible with the screw installed - (ANSWER)Green finish


Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or
other prominent part to distinguish them from fuses of higher ampere rating - (ANSWER)Hexagon


The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or
the nameplate rating, which ever is larger, for each dryer served ? - (ANSWER)5000 watts

Page 2 of 17

, Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____
windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. - (ANSWER)3 ft
(36 inches)


—— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing
installation is where there is no evidence of over-fusing or tampering. - (ANSWER)Class H


Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower
it 90°C 194°F - (ANSWER)3" inches


The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - (ANSWER)8


In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? -
(ANSWER)Combination range hood/microwave oven


Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the
equipment served.if ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the
service or separately derived system disconnect - (ANSWER)Included in the manufactures instructions


Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? - (ANSWER)EVJ


Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed -
(ANSWER)Type S fuse


Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a
lesser distance is permitted by and exceptions - (ANSWER)8'ft


Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings with
conductors of Class 1 or electric light or power conductors, unless ____. - (ANSWER)Separated by barrier


In the critical care areas of health care centers, each patient bed shall be provided with a minimum of ____
duplex receptacles - (ANSWER)3 duplex (6 single)


Page 3 of 17

Escuela, estudio y materia

Institución
NYC MASTER ELECTRICIAN
Grado
NYC MASTER ELECTRICIAN

Información del documento

Subido en
19 de febrero de 2026
Número de páginas
17
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$11.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
mercymutinda
5.0
(1)

Conoce al vendedor

Seller avatar
mercymutinda Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
4
Miembro desde
2 año
Número de seguidores
0
Documentos
670
Última venta
1 mes hace

5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes