Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

NCC Electronic Fetal Monitoring Certification Exam Questions & Answers, A+ Solutions

Puntuación
-
Vendido
-
Páginas
71
Grado
A+
Subido en
14-02-2026
Escrito en
2025/2026

NCC Electronic Fetal Monitoring Certification Exam Questions & Answers, A+ Solutions

Institución
NCC Electronic Fetal Monitoring Certification
Grado
NCC Electronic Fetal Monitoring Certification

Vista previa del contenido

NCC Electronic Fetal Monitoring Certification Exam
Questions & Answers, A+ Solutions
Which of the following factors can have a negative effect on uterine blood flow?
a. Hypertension
b. Epidural
c. Hemorrhage
d. Diabetes
e. All of the above - e. All of the above

How does the fetus compensate for decreased maternal circulating volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement. - b. Increases cardiac
output by increasing it's heart rate.

Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
d. No change - a. A decrease in the heart rate

What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels
e. A & C
f. A & B
g. C & D - g. C & D

The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what
effect to the FHR baseline?
a. Increases baseline
b. Decreases baseline - b. Decreases baseline

T/F: Oxygen exchange in the placenta takes place in the intervillous space. - True

,T/F: The parasympathetic nervous system is a cardioaccelerator. - False

T/F: Baroreceptors are stretch receptors which respond to increases or decreases in
blood pressure. - True

T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart
rate: the ultrasound transducer and the fetal spiral electrode. - True

T/F: Variability can be determined with the fetoscope. - False

T/F: Because the ultrasound transducer and toco transducer are sealed units, they can
be dipped in warm water to make cleaning easier. - False

T/F: The most common artifact with the ultrasound transducer system for fetal heart
rate is increased variability. - True

T/F: All fetal monitors contain a logic system designed to reject artifact. - True

T/F: The monitor should always be tested before starting a tracing, either external or
internal mode and labeled a test. - True

T/F: The paper speed on the fetal monitor should always be set at 1cm/min. - False

T/F: Both internal and external monitoring methods are equally accurate means of
obtaining the fetal heart rate and contraction patterns. - False

T/F: The external toco is usually placed over the uterine fundus to pick up
contractions. - True

T/F: The external toco gives measurable uterine pressure. - False

T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown
origin is present. - False

T/F: The ultrasound transducer is usually placed on the side of the uterus over the
baby's back, as the fetal heart is heard best there. - True

,T/F: The spiral electrode is used to more accurately determine the frequency,
duration, and intensity of uterine contractions. - False

T/F: The heart rate from a well-applied fetal spiral electrode can only be fetal, not
maternal. - False

T/F: The intrauterine catheter is used to pick up the fetal heart rate. - False

T/F: The internal spiral electrode may pick up the maternal heart rate if the baby has
died. - True

T/F: Fetal arrhythmias can be seen on both internal and external monitor tracings. -
True

T/F: Variability and periodic changes can be detected with both internal and external
monitoring. - True

T/F: Variable decelerations are a result of cord compression. - True

T/F: The presence of FHR accelerations in the intrapartum and antepartum periods is
a sign of adequate fetal oxygenation. - True

T/F: Variable decelerations are a vagal response. - True

T/F: Late decelerations have a gradual decrease in FHR (onset to nadir 30 seconds)
and are delayed in timing with the nadir of the deceleration occurring after the peak
of the contraction. - True

T/F: The fetal heart rate baseline can be determined during periods of marked
variability. - False

T/F: Anything that affects maternal blood flow (cardiac output) can affect the blood
flow through the placenta. - True

T/F: Variable decelerations are the most frequently seen fetal heart rate deceleration
pattern in labor. - True

, T/F: Minimal variability is always an indicator of hypoxia and a Cesarean section is
indicated. - False

What is your first intervention in management of a patient experiencing variable
decelerations?
a. Immediate delivery
b. Change maternal position
c. No treatment indicated
d. Oxygen
e. Stop oxytocin infusion - b. Change maternal position

Etiology of a baseline FHR of 165bpm occurring for the last hour can be:
1. Maternal supine hypotension
2. Maternal fever
3. Maternal dehydration
4. Unknown
a. 1 and 2
b. 1, 2 and 3
c. 2, 3 and 4 - c. 2, 3 and 4

What is the most probable cause of recurrent late decelerations?
a. Utero-placental insufficiency
b. Head compression
c. Cord compression
d. Maternal position change - a. Utero-placental insufficiency

The most prevalent risk factor associated with fetal death before the onset of labor is:
a. Low socioeconomic status
b. Fetal malpresentation
c. Uteroplacental insufficiency
d. Uterine anomalies - c. Uteroplacental insufficiency

Which of the following is NOT used for antepartum fetal surveillance?
a. Fetal movement counting
b. Antepartum fetal heart rate testing
c. Biophysical profile testing
d. Maternal HCG levels - d. Maternal HCG levels

Escuela, estudio y materia

Institución
NCC Electronic Fetal Monitoring Certification
Grado
NCC Electronic Fetal Monitoring Certification

Información del documento

Subido en
14 de febrero de 2026
Número de páginas
71
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$19.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
ScoreMasterStudy

Conoce al vendedor

Seller avatar
ScoreMasterStudy Oxford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
5 meses
Número de seguidores
0
Documentos
216
Última venta
3 meses hace

ScoreMaster Study is dedicated to providing high-quality, well-structured study materials designed to help students understand complex topics faster and perform better in exams. All documents are clearly explained, logically organized, and focused on what really matters for tests, assignments, and final exams. Our notes include concise summaries, step-by-step explanations, exam-oriented insights, and practice-focused content that saves you time while maximizing results. Whether you’re revising last-minute or building a strong foundation, ScoreMaster Study helps you study smarter—not harder.

Lee mas Leer menos
0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes