What are the different types of abatement? - ANSWER -
Permanent and
Temporary
The primary focus on Title 17 is what? - ANSWER -Lead
Abatement
What is the minimum area size allowable for lead dust wipe? -
ANSWER -4"x4"
T/F Containment is not required by CDPH if the disturbance
is less than 2sq
feet. - ANSWER -False - containment is always necessary
when using or
distributing any lead containing
material
,What does CDPH require for temporary abatement? - ANSWER -
Notification
What selection method is recommended by HUD when
performing a risk
assessment in a multifamily facility? - ANSWER -
Targeted selection
According to Cal OSHA Title 8, Section 1532.1, what is the title
of the person in
charge of lead projects and oversight? - ANSWER
-Supervisor
T/F For common areas, a representative area on each
painted, stained,
shellacked or varnished testing combination must be tested. -
ANSWER -True
What is Title X? - ANSWER -The Residential Lead Based Paint
Hazard
Reduction Act of 1992 from the Housing and Community
Development Act of 1992
T/F Title X switches the focus from lead based paint hazards to
the presence of
lead based paint. - ANSWER -False - the legislation focuses
on lead based
hazards
,When residential units are sold by the federal government, ____
mandates an inspection and abatement of lead based paint
hazards in residential properties constructed prior to 1960 and
inspection and disclosure of lead based paint hazards for
properties constructed between 1960 and 1978. - ANSWER -
Title X
HUD prohibits paint removal when using heat guns
operating above ___
degrees Fahrenheit to -
ANSWER -1100
Safe work practices must be used during stabilization or
abatement only when
the area of paint begin disturbed is greater than...? - ANSWER
-20 square feet
on exterior
surfaces
2 square feet in an
interior room
10 percent of a building component with a small
surface area
LCCA - ANSWER -Lead Contamination Control Act (1988)
SDWA - ANSWER -Safe Drinking Water Act
What is a Category I waste? - ANSWER -Low lead waste
, What is a Category II waste? - ANSWER -Architectural
componenets
What is a Category III waste? - ANSWER -Concentrated lead
waste
What is a Category IV waste? - ANSWER -Other waste
How many readings do you need to take for a substrate
correction? - ANSWER -6
For pre-1960 or unknown age buildings or developments with
1,040 or more similar units, common areas or exterior sites,
test ___of them and round u to the next whole number. -
ANSWER -5.8%
For 1960-77 buildings or developments with 1,000 ore more
units, test ___of
the units and round up any fraction to the next whole number. -
ANSWER -2.9%
What is the least number of components of a given type that
must be tested to
obtain the desired level of confidence in the results throughout
the multi-family
housing development? -
ANSWER -40
T/F You do not need to complete all XRF testing to conclude
that all components in a given component type are negative for