CT Septic Exam Question with complete
Solutions New update 2026 Grade A+
QUESTIONS AND ANSWERS
What are the capacities for each side of a septic tank?. ANSWER -2/3 inlet side, 1/3 outlet
side


How many inches lower should the outlet be from the inlet in a septic tank?. ANSWER -3"


What information must be present on the outlet side of a septic tank?. ANSWER -- Name
of manufacturer
- Date manufactured
- Size of tank in gallons
- External load limit
- Warning placard


How many additional gallons per bedroom are required for each bedroom beyond 3?.
ANSWER -125 gallons


How many additional gallons per bedroom are required for each bedroom beyond 4?.
ANSWER -225 gallons


How far below finished grade can clean out and baffle inspection manholes be?. ANSWER -
No deeper than 12"


Tank riser covers shall be at least _________ lbs, or_______________________, or
_______________________________. ANSWER -59 lbs, tank covers shall remain on tank
clean outs, a secondary safety device shall be provided


What are the 3 main functions of a septic tank?. ANSWER -1. Removes most of the
settleable solids

, 2. Provides and effluent of relatively uniform physical, chemical and biological
characteristics
3. Provides some reduction in pollution levels in the effluent


Where should perc tests be conducted?. ANSWER -In primary and reserve septic areas


How many inches maximum should a perc hole be?. ANSWER -12"


How many inches of water shall be used for a perc test presoak?. ANSWER -12"


How many inches of water shall be used for a perc test?. ANSWER -12"


How many consecutive readings shall be taken for a perc test. ANSWER -3


Perc test readings are measured to the nearest ______". ANSWER -1/8"


What is the perc rate calculation?. ANSWER -Time/Reading in inches


No leaching system shall be constructed in areas where:. ANSWER -- High groundwater
- Surface flooding
- Ledge rock


Leaching system shall be a minimum of 18" above:. ANSWER -- Groundwater
- Mottling
- Hardpan


Leaching system shall be ____' above ledge or fractured rock. ANSWER -4'


Leaching system shall be ____" above decomposing ledge (rock). ANSWER -24"

Información del documento

Subido en
28 de enero de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
8
Seguidores
0
Artículos
1069
Última venta
1 mes hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes