100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ABSA: 4th Class Part B – Comprehensive Power Engineering Exam 1| Correct Solutions

Puntuación
-
Vendido
-
Páginas
35
Grado
A+
Subido en
21-01-2026
Escrito en
2025/2026

ABSA: 4th Class Part B – Comprehensive Power Engineering Exam 1| Correct Solutions

Institución
Power Engineering
Grado
Power Engineering











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Power Engineering
Grado
Power Engineering

Información del documento

Subido en
21 de enero de 2026
Número de páginas
35
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ABSA: 4th Class Part B –
Comprehensive Power Engineering
Exam 1| Correct Solutions

Temporary hardness in feedwater is caused by:
Select one:

a. Magnesium sulphate
b. Calcium carbonate
c. Magnesium bicarbonate
d. Sodium nitrate - Ans--c

What is the recommended boiler water pH for wet layup?
Select one:

a. 10
b. 12
c. 7.5
d. 7 - Ans--a

A photoelectric flame scanner:
Select one:

a. Produces a steady voltage signal
b. Requires a clear line of sight to the flame
c. conducts current through the flame
d. uses a pilot-stat - Ans--b

Heavy oil recovered using SAGD or CSS is properly referred to as
Select one:

a. bottoms
b. crude
c. tar

,d. bitumen - Ans--d

Humidifying units that force warm air through a wet pad, and return the air to
the room, are called:
Select one:

a. Wetted element humidifiers
b. Pan type humidifiers with plates
c. Atomizing humidifiers
d. Bypass type humidifiers - Ans--a

The kind of grease used for heavily loaded machinery operating at slow
speeds is the:
Select one:

a. Sodium base grease
b. Specialty grease
c. Calcium base grease
d. Aluminum base grease - Ans--b

One of the advantages of gas-fired infrared heating over other types of
heating systems is:
Select one:

a. Gas-fired infrared heaters can be used as the main heating source for a
large building
b. Gas-fired infrared heaters can provide effective spot heating
c. Gas-fired infrared heaters require no fuel handling equipment
d. Gas-fired infrared heaters can heat large volume enclosures with little fuel
- Ans--b

The normal loss of zeolite in a sodium zeolite softener is about _______ per
year.
Select one:

a. 0.1
b. 0.15
c. 0.03

,d. 0.05 - Ans--c

A form of lubrication that requires continual motion of a shaft or surface is:
Select one:

a. Fluid film lubrication
b. Forced lubrication
c. Continuous lubrication
d. Boundary lubrication - Ans--a

A ________ is a fired heater installed where the heat is needed, that heats
the air directly without the use of any ducting.
Select one:

a. Rooftop unit
b. Unit ventilator
c. Convector
d. Unit heater - Ans--d

With antifriction bearings using grease, the bearings:
Select one:

a. Never require cleaning
b. Are cleaned less often than oil-lubricated bearings
c. can be cleaned by adding solvent to the grease cartridge
d. Must be cleaned twice as often as oil-lubricated bearings - Ans--b

In a reaction turbine the steam ____________ when passing through
moving blades.
Select one:

a. Velocity decreases
b. Velocity remains constant
c. Pressure decreases
d. Pressure increases - Ans--c

Which one of these government agencies or regulations covers the use and
erection of work platforms?

, Select one:

a. Provincial elevator and hoisting device inspection branch
b. Industrial Accident Prevention Association
c. Occupational Health and Safety Act and Regulation
d. Boilers and Pressure Vessels Branch - Ans--c

An evaporator that can easily be cleaned and defrosted manually without
interrupting the cooling process is which type of evaporator?
Select one:

a. Shell and tube evaporator
b. Plate surface evaporator
c. Finned evaporator
d. Liquid recirculating evaporator - Ans--b

Air removal prior to a hydrostatic test:
Select one:

a. Is critical, because the air will compress during the test
b. Will prevent oxygen corrosion.
c. Is done by adding oxygen scavenging chemicals to the test water.
d. Is done with a vacuum pump. - Ans--a

Rust in the gauge glass is an indication that:
Select one:

a. Corrosion is occurring in the system
b. The continuous blowdown setting needs to be increased.
c. The dissolved solids concentration has peaked.
d. The boiler should be blown off. - Ans--a

The purpose of humidification is to:
Select one:

a. Remove moisture from the air during the heating season
b. Remove moisture from the air during the cooling season
c. Add moisture to the air during the cooling season
$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
SIRJOHNES

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
SIRJOHNES stuvia
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
Nuevo en Stuvia
Miembro desde
2 semanas
Número de seguidores
0
Documentos
201
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes