100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

TFM 12 Fire Alarm Technical Test with 100% Correct Answers REVISED & VERIFIED|| LATEST UPDATE 2026/27

Puntuación
-
Vendido
-
Páginas
16
Grado
A+
Subido en
18-01-2026
Escrito en
2025/2026

TFM 12 Fire Alarm Technical Test with 100% Correct Answers REVISED & VERIFIED|| LATEST UPDATE 2026/27

Institución
TFM 12 Fire Alarm Technical
Grado
TFM 12 Fire Alarm Technical










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
TFM 12 Fire Alarm Technical
Grado
TFM 12 Fire Alarm Technical

Información del documento

Subido en
18 de enero de 2026
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

TFM 12 Fire Alarm Technical Test with
100% Correct Answers REVISED &
VERIFIED|| LATEST UPDATE 2026/27


Does a fire hood system and a kitchen need to be monitored by the fire alarm system? -

CORRECTANSWER Yes



What does P.L.F.A stand for? -CORRECTANSWER Power Limited Fire Alarm



What does N.P.L.F.A stand for? -CORRECTANSWER Non-Power Limited Fire Alarm



What is the difference between P.F.L.A and N.P.F.L.A? -CORRECTANSWER an

N.P.L.F.A can operate at up to 600v, and the power output isn't limited



a P.L.F.A has the voltage and power limited by a listed power source.



What material must N.P.F.L.A circuit conductors be made from? -CORRECTANSWER

ONLY solid stranded copper is permitted.



What does A.W.G stand for? -CORRECTANSWER American Wire Gauge

,What size conductors are permitted? -CORRECTANSWER Size 18 A.W.G and 16

A.W.G are permitted, provided they do not exceed certain capacities.



What is used to protect transformers or other devices supplied from power-supply

conductors? -CORRECTANSWER An over-current device not rated over 20 amperes.



When located within 7 feet of the floor, how shall cables be fastened? -

CORRECTANSWER Cables shall be fastened in an approved manner at intervals of

not more than 18 inches.



Single conductors shall not be smaller than ___ A.W.G? -CORRECTANSWER 18



Conductors of 28 A.W.G shall only be permitted in which circumstance? -

CORRECTANSWER Spliced with a connector listed as suitable for 26 to 24 A.W.G



How shall P.F.L.A conductors NOT be installed? -CORRECTANSWER P.F.L.A

conductors shall not be strapped, taped, or attached to the exterior of any conduit or

raceway.



What is Plenum cable? -CORRECTANSWER Cable that can be installed in ducts,

plenums, or other spaces used for environmental air.

, What is a Riser cable? -CORRECTANSWER Cable to be used in vertical wire runs in

shafts between floors. Not to be used where Plenum cable is required.



It is capable of preventing fire from rising from floor to floor.



What is general purpose cable? -CORRECTANSWER Cable for general purpose fire

alarm use. Not to be used where plenum cable or riser cable is required.



It is resistant to the spread of fire.



Why 'type' shall plenum cable be? What substitutions are allowed? -

CORRECTANSWER Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be

substituted.



Why 'type' shall riser cable be? What substitutions are allowed? -CORRECTANSWER

Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P.



C.M.R can be substituted.



What 'type' shall general purpose wire be? What substitutions are permitted? -

CORRECTANSWER Power Limited Fire Alarm (F.P.L) C.M.P, F.P.L.P, C.M.R, F.P.L.R,

C.M.G
$18.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ExamSuccessHub Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
175
Miembro desde
1 año
Número de seguidores
5
Documentos
2193
Última venta
1 día hace

4.1

9 reseñas

5
5
4
2
3
1
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes