Free play is the distance that the pedal must be pushed before the _________ actually contacts
the clutch release fingers.
Throw-out Bearings
NFPA 1911 specifies that all gauges used for service must be calibrated within ____ of testing
60 days
Other than locked wheel skid, what other kind of skid is common
Acceleration Skid
The _______ evaluates the overall operation of the engine and fire pump
Pumping Test
You should avoid discharging foam concentrated solutions or finished foam directly into
_____________.
a body of water
The U.S. Bureau of land management conducted research that resulted in the development of this
high energy foam
Class A
Intake hose is common in 10ft. to ___ lengths?
100 ft.
What can result in the clutch not releasing completely causing harsh shifting, gear clashing, and
damage to gear teeth?
Excessive free play
Reaction distance
Braking distance
Top Heavy
1
, Facing forward (away from you)
Rescue vehicles commonly have generators with capacities up to ____________.
50,000 Watts
NFPA 1901 brake test requires that a new fire apparatus be brought to a complete stop from a
speed of 20mph in a distance not to exceed _______
35 Ft.
When driving through smoke what should be done besides sounding horn.
Drive Close to The Crew
Because total vacuum is not possible in field operations, fire apparatus must have a maximum lift
of ______
25 Ft.
NFPA 1901 specifies that the minimum pump capacity for pump design is:
750 GPM
When drafting, the maximum theoretical lift is:
33.90 Ft.
According to NFPA 1901, a mobile water supply apparatus must carry at least
1,000 Gal.
Tiller training question (don't remember how question was structured)
NFPA 1800 allows for a detachable seat to be placed next to tiller operator's position to remain in
close contact with operator
Portable generators are designed to provide power with ____ watts of power being the largest.
5,000 Watts
Dependable Lift = ______ Feet.
14.7 Ft.
On apparatus with air brakes, NFPA requires the air pressure to build to a sufficient level to allow
vehicle operations within ___ seconds of starting.
60
2
2027 WITH ACTUAL CORRECT QUESTIONS AND
ANSWERS|CURRENTLY TESTING VERSION|ALREADY GRADED
A+|GUARANTEED PASS
Free play is the distance that the pedal must be pushed before the _________ actually contacts
the clutch release fingers.
Throw-out Bearings
NFPA 1911 specifies that all gauges used for service must be calibrated within ____ of testing
60 days
Other than locked wheel skid, what other kind of skid is common
Acceleration Skid
The _______ evaluates the overall operation of the engine and fire pump
Pumping Test
You should avoid discharging foam concentrated solutions or finished foam directly into
_____________.
a body of water
The U.S. Bureau of land management conducted research that resulted in the development of this
high energy foam
Class A
Intake hose is common in 10ft. to ___ lengths?
100 ft.
What can result in the clutch not releasing completely causing harsh shifting, gear clashing, and
damage to gear teeth?
Excessive free play
Reaction distance
Braking distance
Top Heavy
1
, Facing forward (away from you)
Rescue vehicles commonly have generators with capacities up to ____________.
50,000 Watts
NFPA 1901 brake test requires that a new fire apparatus be brought to a complete stop from a
speed of 20mph in a distance not to exceed _______
35 Ft.
When driving through smoke what should be done besides sounding horn.
Drive Close to The Crew
Because total vacuum is not possible in field operations, fire apparatus must have a maximum lift
of ______
25 Ft.
NFPA 1901 specifies that the minimum pump capacity for pump design is:
750 GPM
When drafting, the maximum theoretical lift is:
33.90 Ft.
According to NFPA 1901, a mobile water supply apparatus must carry at least
1,000 Gal.
Tiller training question (don't remember how question was structured)
NFPA 1800 allows for a detachable seat to be placed next to tiller operator's position to remain in
close contact with operator
Portable generators are designed to provide power with ____ watts of power being the largest.
5,000 Watts
Dependable Lift = ______ Feet.
14.7 Ft.
On apparatus with air brakes, NFPA requires the air pressure to build to a sufficient level to allow
vehicle operations within ___ seconds of starting.
60
2