100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

HVAC EXCELLENCE ACTUAL FINAL EXAM QUESTIONS COMPLETE WITH VERIFIED ANSWERS|

Puntuación
-
Vendido
-
Páginas
11
Grado
A+
Subido en
09-01-2026
Escrito en
2025/2026

HVAC EXCELLENCE ACTUAL FINAL EXAM QUESTIONS COMPLETE WITH VERIFIED ANSWERS| Q.Before working on an electric furnace the tech should - ANSWERS-Review diagram, remove jewelry, and follow safety procedures. ALL OF THE ABOVE. Q.A GFCI circuit breaker - ANSWERS-detects current leaks to groound Q.the conductor in an electric heat element is usually made of - ANSWERS-Nichrome Q.An example of resistive load is - ANSWERS-crankcase heater Q.an example of an inductive load is - ANSWERS-motor Q.an electric furnace is marked 208/230 single phase 60Hz A tech reads 200 vac at the power supply and determines - ANSWERS-the voltage is too low Q.voltage imbalance between any leg of 3 phase power supply may not exceed - ANSWERS-2% Q.the limit switch on an electric furnace is a - ANSWERS-Automatic reset switch Q.the sequencer timers on electric heater will usually energize the 1st heating element after a time delay of - ANSWERS-1 to 30 sec Q.the amount of btus produced by 1 watt of electricity is - ANSWERS-3.413 btus Q.a tech reads 60 amps with a clamp on amp meter on a forced air furnace. the supply voltage is 230 volts AC, approx how many watts is the furnace using - ANSWERS-13,800 Q.a furnace is using 15,500 watts approx Kw - ANSWERS-15.5 Kw Q.a sequencer timer use _____ to close the contact points to the heater element - ANSWERS-heated snap-discs or bi-metal strips Q.an electric furnace heating thermostat must - ANSWERS-open on rise close on drop Q.a standard thermostat heat anticipator is ____ and wired in ____ with the heating control - ANSWERS-adjustable/series Q.some thermostat manufacturers require a jumper connection on the thermostat subbase of heating and cooling thermostat in order to - ANSWERS-use a single transformer Q.most electric heat elements use the following safties to prevent overheating - ANSWERS-snap disc and fusible link Q.a tech reads 70 amps to the single phase heater . the supply voltage is 230 volts Ac. Approx how many btus is the furnace producing - ANSWERS-54,949 Q.the control that prevents duct heater from operating unless there is adequate supply air is - ANSWERS-fan interlock Q.the COP for electric resistance heat is - ANSWERS-1 to 1 Q.what is the maximum kW element used on each contact of a residential heat sequencer - ANSWERS-5 kW Q.electric heaters are generally rated at ____ volts ac for kW output - ANSWERS-240 Q.the first stage of a sequencer usually has a set of contacts to - ANSWERS-start the blower fan motor Q.an automatic reset safety on a heater element generally opens at ____*F - ANSWERS-130-190*F Q.most heating elements are mounted on which type of insulator - ANSWERS-mica or ceramic Q.a 10 kW electric heater operating at 240 v draws 42 amps, what will a 10 kW heater wired to 480 volts draw - ANSWERS-21 amps Q.the purpose of a sequencer is to - ANSWERS-avoid a sudden power load Q.two major factors in determining the temp rise of an electric furnace are - ANSWERS-furnace KW and CFM Q.a major cause of electrical heat element burn out - ANSWERS-low airflow Q.a tech is checking the resistance on delta wired 3 phase 240 v 15 kW electic duct heater if one element is open he would read - ANSWERS-L1 to L2 22Ohm L1 to L3 22ohm L2 to L3 infinity

Mostrar más Leer menos
Institución
HVAC EXCELLENCE
Grado
HVAC EXCELLENCE









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
HVAC EXCELLENCE
Grado
HVAC EXCELLENCE

Información del documento

Subido en
9 de enero de 2026
Número de páginas
11
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

HVAC EXCELLENCE ACTUAL FINAL EXAM QUESTIONS
COMPLETE WITH VERIFIED ANSWERS|


\Q\.Before working on an electric furnace the tech should - ANSWERS✔-Review diagram,
remove jewelry, and follow safety procedures. ALL OF THE ABOVE.



\Q\.A GFCI circuit breaker - ANSWERS✔-detects current leaks to groound



\Q\.the conductor in an electric heat element is usually made of - ANSWERS✔-Nichrome



\Q\.An example of resistive load is - ANSWERS✔-crankcase heater



\Q\.an example of an inductive load is - ANSWERS✔-motor



\Q\.an electric furnace is marked 208/230 single phase 60Hz A tech reads 200 vac at the power
supply and determines - ANSWERS✔-the voltage is too low



\Q\.voltage imbalance between any leg of 3 phase power supply may not exceed - ANSWERS✔-
2%



\Q\.the limit switch on an electric furnace is a - ANSWERS✔-Automatic reset switch



\Q\.the sequencer timers on electric heater will usually energize the 1st heating element after a
time delay of - ANSWERS✔-1 to 30 sec



\Q\.the amount of btus produced by 1 watt of electricity is - ANSWERS✔-3.413 btus

, \Q\.a tech reads 60 amps with a clamp on amp meter on a forced air furnace. the supply
voltage is 230 volts AC, approx how many watts is the furnace using - ANSWERS✔-13,800



\Q\.a furnace is using 15,500 watts approx Kw - ANSWERS✔-15.5 Kw



\Q\.a sequencer timer use _____ to close the contact points to the heater element -
ANSWERS✔-heated snap-discs or bi-metal strips



\Q\.an electric furnace heating thermostat must - ANSWERS✔-open on rise close on drop



\Q\.a standard thermostat heat anticipator is ____ and wired in ____ with the heating control -
ANSWERS✔-adjustable/series



\Q\.some thermostat manufacturers require a jumper connection on the thermostat subbase of
heating and cooling thermostat in order to - ANSWERS✔-use a single transformer



\Q\.most electric heat elements use the following safties to prevent overheating - ANSWERS✔-
snap disc and fusible link



\Q\.a tech reads 70 amps to the single phase heater . the supply voltage is 230 volts Ac. Approx
how many btus is the furnace producing - ANSWERS✔-54,949



\Q\.the control that prevents duct heater from operating unless there is adequate supply air is -
ANSWERS✔-fan interlock



\Q\.the COP for electric resistance heat is - ANSWERS✔-1 to 1
$12.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
IszackBd
5.0
(1)

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
IszackBd University Of Washington
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
7
Miembro desde
1 año
Número de seguidores
1
Documentos
2702
Última venta
5 días hace
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Lee mas Leer menos
5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes