1. ASTM E2886
Answer Standard for testing ability of exterior vents to resist ember entry
2. NFPA 1142 Standard for Water Supplies for Suburban and Rural Fire
Fighting
Answer At minimum every building shall be provided with a water supply meeting requirements of
.
3. 1) Education
2) Engineering
3) Enforcement
Answer Wildland Fire Mitigation activities fall into what 3 broad categories?
4. 10%
Answer Steepest allowable road grade (without other mitigation measures agreed on by AHJ)
5. NFPA 1143 Standard for Wildland Fire Management
Answer Which NFPA standard provides minimum requirements to fire protection organizations on the
1/
12
, management of wildland fire, including prevention, mitigation, preparation and suppression?
6. Solid-core wood no less than 1 3/4 inch thick
approved non-combustible material
or have a minimum 20 min fire rating
Answer Exterior doors shall be
7. 13 ft 6 inch vertical
Unobstructed width of 20ft
Answer Vertical clearance for roadways and unobstructed width
8. heavy timber, ignition resistant material, fire-retardant treated wood, or have
minimum 1 hour fire rated construction material (Unless AHJ declares risk
warrants greater protection)
Answer Exterior walls shall be
9. heavy timber construction, non-combustible material, fire-retardant treated
wood, other ignition resistant materials, or have a 1 hour fire rating
Answer All projections (balconies, decks, etc) shall be of
2/
12