100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NETA III Exam Questions And Correct Answers| Updated 2026

Puntuación
-
Vendido
-
Páginas
54
Grado
A+
Subido en
07-01-2026
Escrito en
2025/2026

NETA III Exam Questions And Correct Answers| Updated 2026

Institución
NETA III
Grado
NETA III











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NETA III
Grado
NETA III

Información del documento

Subido en
7 de enero de 2026
Número de páginas
54
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NETA III Exam Questions And Correct
Answers| Updated 2026




The alternate source for emergency systems are required to be equipped with
ground-fault protection of equipment.
False




Which ANSI/IEEE standard covers SF6 circuit breakers?
C37.04




You measure the winding resistance of a 12.4kV, 1000kVA, Delta-Delta connected
transformer with a 100A test set. H1-H2 measures 42.0 microhms, H2-H3
measures 41.9 microhms, and H3-H1 measures 84.0 microhms. What can you
conclude from these readings?
One phase of the transformer is open.




When monitoring for entries involving a decent into atmospheres that may be
stratified, the envelope should be tested at a distance of approximately _____ feet
in the direction of travel and to each side.

,4




The transformer manufacturer should be consulted if winding-resistance test
values vary by more than _____ percent from factory test values or between
adjacent phases according to NETA acceptance testing standards.
2




A DC shunt motor should never be operated:
with the field circuit open




What is the expected torque (pound-feet) value of a 3/8" Grade 5 bolt?
20




The generally accepted limits of deviation from the nominal 60Hz utility power
frequency is:
.50Hz




Power Factor testing is least effective on which of the following?
MV Cable

,Which of the following insulating liquid tests is optional when maintenance
testing a 13.2kV-4.16kV 1500kVA transformer with silicone fluid per NETA
standards?
ASTM D1298




Panelboards equipped with snap switches of rating 30 amps or less shall be
provided with over-current protection of not more than _____ .
200 amps




Underground service conductors between the terminals of service equipment and
service lateral or underground service conductors are termed as _____ .
Service Entrance Conductors




What is a dual element fuse used for?
Operate with a temporary overload




The full-load current for a single-phase alternating current 115 volt, 1 horsepower
motor is which of the following:
16 A

, Infrared surveys should be performed during periods of maximum possible
loading but not less than _____ % of rated load of the electrical equipment being
inspected.
40




Decreasing the opening time of the overcurrent protective device will decrease
Arc-Flash hazards.
true




In a wye connected system, without neutral grounding, zero sequence currents
are:
zero




When evaluating insulation test results on a medium-voltage, air-magnetic circuit
breaker, what quantity is evaluated?
watts-loss




In accordance with NETA and IEEE standards, the correct acceptance test voltage
(dc) for 35KV rated EPR 133% insulation level cable is?
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
KelvinBrooks West Virgina University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
267
Miembro desde
1 año
Número de seguidores
6
Documentos
3046
Última venta
1 día hace
Brooks

Welcome to Brooks Study guides! The place to find the best study materials for various subjects. You can be assured that you will receive only the best which will help you to ace your exams. All the materials posted are A+ Graded. Thank you very much!

4.1

31 reseñas

5
14
4
6
3
10
2
1
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes