FDNY Z51 RMO EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026/2027 the efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the following, a more efficient centrifugal compressor operation results from - Answers lowering the condenser pressure In most semi hermetic compressors, the suction vapor is used for - Answers cools the motor The amount of refrigerant that flows through the orifices of an economizer is determined by the - Answers difference between the high side and the low side pressure the instalation of an inline refrigerant cleaning system is advisable - Answers to remove impurities from the system a refrigerant engineer verifies that a condenser pump is cavitation of the following the most likely cause for this condition is: - Answers a faulty cooling tower water level controller when an expansion valve is operating properly, at the end of the evaporator will contain - Answers only superheated vapor a centrifugal water pump is considered to be fully primed when - Answers the pump is full of liquid A refrigeration compressor has failed to turn on. the engineer on duty verifies the electrical circuit to the motor, including all switches and circuit breakers is complete, according to recomended service practice, the next item to be checked would likely be the: - Answers temperature and pressure controls Refrigerants are characterized by their physical properties including Flashpoint, refrigeration effect and others, of the refrigerants in commercial and industrial the highest latent heat and refrigerant effect is: - Answers ammonia which of the following ashrae refrigerant safety classification is the most toxic - Answers b3 which of the following ashrae refrigerant safety classification is the most flammable - Answers a3 in q indirect refrigeration system,of the following, the one that would not be used as a cooling medium for building spaces being cooled is - Answers r 22 (cooling medium= glycol or any brine solution) the primary way of achieving capacity control of a an centrifugal compressor is by: - Answers adjustment to the inlet impeller pre rotation vanes regarding the functioning of a steam turbine, why is it advisable to keep moisture in the inlet low as possible - Answers keeps turbine blades wear to minimum a water chiller is equipped with a reciprocating compressor, a thermostatic expansion valve and a an air cooled condenser. A restriction in the refrigerant line would result in - Answers high suction super heat the process by which refrigerant is extracted and cleaned for reuse without requirements for reclamation is called - Answers recycle the purpose of wear rings in a centrifugal pump is to - Answers prevent wearing of the pump housing and impeller a centrifugal compressor is in operation with suction pressure is 3 psig and the discharge is 10psi what is the atmospheric pressure is 14.7 which is the ratio closest to - Answers 1.39 electrical current us measured in - Answers amperage how would you put an additional pump online - Answers open suction valve, open discharge valve gradually of the following, the major advantage of a shell and coil condenser is - Answers there is less danger of developing leaks an engineer needs to vary the flow of refrigerant in a refrigeration system, which operation in the flow of the system does not include - Answers solenoid valve thermal bull is attached to the suction plate between the evaporator cokl and the compressor by an insulated line. assume that the machine room is 85deg f . break down of the insulation results in: - Answers flood the evaporator water and moisture is serious problem in a refrigerant system how to avoid - Answers proper evaluation at the charging of the system while on duty a refrigeration engineer notic That the suction line to the compressor and part of the compressor itself is frosted over the following the most likely reason for this condition would be - Answers There is not enough Refrigerant in the system While doing a routine inspection the engineer notices the bulb of the TXV on the floor. The refrigerant engineer should have attached a bulb at the - Answers The outlet end of the coil A refrigerant engineer verifies that a chilled water pump is cavity to of the following the most likely cause for this condition is - Answers Water leaks through the mechanical seals The only refrigerant/temperature chart available to a refrigeration engineer lists the temperature In ゚C if the chart indicates a Celsius temperature of 4゚ this is equivalent to - Answers 39.2゚ The use of oil in the refrigeration machine is to - Answers Reduce wear and friction in the compressor parts Which of the following will connect to the Middle port on a gauge manifold - Answers Vacuum pump

Mostrar más Leer menos
Institución
FDNY Z51 RMO
Grado
FDNY Z51 RMO









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
FDNY Z51 RMO
Grado
FDNY Z51 RMO

Información del documento

Subido en
7 de enero de 2026
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

FDNY Z51 RMO EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026/2027

the efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the
following, a more efficient centrifugal compressor operation results from - Answers lowering
the condenser pressure

In most semi hermetic compressors, the suction vapor is used for - Answers cools the motor

The amount of refrigerant that flows through the orifices of an economizer is determined by the
- Answers difference between the high side and the low side pressure

the instalation of an inline refrigerant cleaning system is advisable - Answers to remove
impurities from the system

a refrigerant engineer verifies that a condenser pump is cavitation of the following the most
likely cause for this condition is: - Answers a faulty cooling tower water level controller

when an expansion valve is operating properly, at the end of the evaporator will contain -
Answers only superheated vapor

a centrifugal water pump is considered to be fully primed when - Answers the pump is full of
liquid

A refrigeration compressor has failed to turn on. the engineer on duty verifies the electrical
circuit to the motor, including all switches and circuit breakers is complete, according to
recomended service practice, the next item to be checked would likely be the: - Answers
temperature and pressure controls

Refrigerants are characterized by their physical properties including Flashpoint, refrigeration
effect and others, of the refrigerants in commercial and industrial the highest latent heat and
refrigerant effect is: - Answers ammonia

which of the following ashrae refrigerant safety classification is the most toxic - Answers b3

which of the following ashrae refrigerant safety classification is the most flammable - Answers
a3

in q indirect refrigeration system,of the following, the one that would not be used as a cooling
medium for building spaces being cooled is - Answers r 22 (cooling medium= glycol or any brine
solution)

the primary way of achieving capacity control of a an centrifugal compressor is by: - Answers
adjustment to the inlet impeller pre rotation vanes

regarding the functioning of a steam turbine, why is it advisable to keep moisture in the inlet low
as possible - Answers keeps turbine blades wear to minimum

, a water chiller is equipped with a reciprocating compressor, a thermostatic expansion valve and
a an air cooled condenser. A restriction in the refrigerant line would result in - Answers high
suction super heat

the process by which refrigerant is extracted and cleaned for reuse without requirements for
reclamation is called - Answers recycle

the purpose of wear rings in a centrifugal pump is to - Answers prevent wearing of the pump
housing and impeller

a centrifugal compressor is in operation with suction pressure is 3 psig and the discharge is
10psi what is the atmospheric pressure is 14.7 which is the ratio closest to - Answers 1.39

electrical current us measured in - Answers amperage

how would you put an additional pump online - Answers open suction valve, open discharge
valve gradually

of the following, the major advantage of a shell and coil condenser is - Answers there is less
danger of developing leaks

an engineer needs to vary the flow of refrigerant in a refrigeration system, which operation in the
flow of the system does not include - Answers solenoid valve

thermal bull is attached to the suction plate between the evaporator cokl and the compressor by
an insulated line. assume that the machine room is 85deg f . break down of the insulation
results in: - Answers flood the evaporator

water and moisture is serious problem in a refrigerant system how to avoid - Answers proper
evaluation at the charging of the system

while on duty a refrigeration engineer notic That the suction line to the compressor and part of
the compressor itself is frosted over the following the most likely reason for this condition
would be - Answers There is not enough Refrigerant in the system

While doing a routine inspection the engineer notices the bulb of the TXV on the floor. The
refrigerant engineer should have attached a bulb at the - Answers The outlet end of the coil

A refrigerant engineer verifies that a chilled water pump is cavity to of the following the most
likely cause for this condition is - Answers Water leaks through the mechanical seals

The only refrigerant/temperature chart available to a refrigeration engineer lists the temperature
゚ ゚
In C if the chart indicates a Celsius temperature of 4 this is equivalent to - Answers 39.2 ゚
The use of oil in the refrigeration machine is to - Answers Reduce wear and friction in the
compressor parts
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorJosh Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
361
Miembro desde
1 año
Número de seguidores
16
Documentos
29479
Última venta
5 días hace
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

58 reseñas

5
20
4
15
3
12
2
0
1
11

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes