100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Q 01 FDNY Exam Newest /Q 01 FDNY Exam Preparation/Q 01 FDNY Practice Exam With Complete Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!

Puntuación
-
Vendido
-
Páginas
31
Grado
A+
Subido en
06-01-2026
Escrito en
2025/2026

Q 01 FDNY Exam Newest /Q 01 FDNY Exam Preparation/Q 01 FDNY Practice Exam With Complete Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!

Institución
Q 01 FDNY
Grado
Q 01 FDNY











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Q 01 FDNY
Grado
Q 01 FDNY

Información del documento

Subido en
6 de enero de 2026
Número de páginas
31
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Q-01 FDNY Exam Newest /Q-01 FDNY Exam
Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified
Answers) |Already Graded A+|Brand New Version!!
Which of the following statements is incorrect?
A) A service valve is a key-operated shut-off valve used during shipment,
installation and repairs
B) Brine is a liquid cooled by refrigeration and used for the transmission of heat
C) A fusible plug has a set-temperature fusible member to relieve pressure
D) A rupture member automatically ruptures at a predetermined temperature -
ans -D) A rupture member automatically ruptures at a predetermined
temperature

Oil in a refrigerant should
A) have a high pour point
B) have a low flash point
C) have a high viscosity
D) not contain moisture - ans -D) not contain moisture

In an NH3 dry expansion evaporator with TXV and bulb clamped properly on the
outlet of the evaporator, the superheat is
A) 7 to 10° F
B) 5 to 9° F
C) 20 to 30° F
D) 1 to 2° F - ans -A) 7 to 10° F

The setting of a fusible plug is
A) 280° F
B) 300° F
C) 380° F
D) 300 psig. - ans -A) 280° F

If the insulation was removed from the bulb of the expansion valve, what would
happen? - ans -Flooded evaporator —the TXV bulb opens in a range from 45 to

,85° F. If the insulation was removed, the bulb would sense the temperature in the
machine room and keep the TXV open, thus flooding the evaporator.

On the most common three-phase, four-wire service, the voltage between any
phase and neutral should be
A) 105 volts
B) 120 volts
C) 208 volts
D) 220 volts - ans -B) 120 volts

A refrigerant overcharge would
A) increase head pressure
B) decrease head pressure
C) decrease solution-side pressure
D) decrease discharge-side pressure - ans -A) increase head pressure

A dryer is generally installed with other equipment in a commercial Freon
compressor system. The recommended location of this dryer is on the
A) high-pressure line between condenser and reciever
B) suction line between evaporator and compressor
C) discharge line between compressor and condenser
D) liquid line between receiver and expansion valve - ans -D) liquid line between
receiver and expansion valve

R-22 —What does it smell like? - ans -Odorless

Desirable characteristics of a refrigerant:
A) High __________
B) Low __________ - ans -A) High critical point
B) Low freezing point

Centrifugal Feed Water Pump
A) Start-up procedure
B) Shut-down procedure - ans -A) Start-up procedure
1) Lock-out, tag-out
2) Close discharge valve
3) Open suction valve

,4) Turn on
5) Open discharge valve
B) Shut-down procedure
1) Lock-out, tag-out
2) close suction valve
3) close discharge valve

In order to vary the capacity of an absorption plant, you should regulate the.. -
ans -Flow of the water to the condenser

600,000 btu per hour equals how many tons of refrigeration?
A) 300
B) 3,000
C) 500
D) 50 - ans -D) 50

Heat transfer takes place by
A) evaporation, conduction and condensation
B) radiation, conduction and convection
C) condensation, evaporation and radiation
D) sublimation, evaporation and convection - ans -B) radiation, conduction and
convection

Refrigerant recovery is defined as
A) Removing the refrigerant from a system and storing it in an external container,
with the lowest emissions possible.
B) Reprocessing a refrigerant into a new product that can be reused in another
system.
C) The process of cleaning a refrigerant of dirt and contaminates, such as oil, acid,
foreign material and non condensibles.
D) None of the above. - ans -A) Removing the refrigerant from a system and
storing it in an external container, with the lowest emissions possible.

A 10-ton refrigeration unit has a capacity of
A) 2,000 btu/minute
B) 12,000 btu/minute
C) 20,000 btu/minute

, D) 144,000 btu/day - ans -A) 2,000 btu/minute

In an absorption system, the medium normally used to vaporize refrigerant and
increase its temperature is
A) water
B) propane
C) ethylene
D) steam - ans -D) steam

Any water present in the refrigerant side of a Freon refrigerating system causes a
A) clogged oil trap
B) frozen discharge valve
C) clogged scale trap
D) frozen expansion valve - ans -D) frozen expansion valve

The subcooling effect of the liquid refrigerant just before the expansion valve
causes increased
A) horsepower
B) refrigeration effect
C) expansion valve capacity
D) refrigerant flow - ans -B) refrigeration effect

In a flooded evaporator using an accumulator and float valve, flash gas
A) passes directly into the evaporator
B) passes directly into the suction line
C) does not occur
D) stays in the receiver - ans -B) passes directly into the suction line

According to Title 49 CFR Section 173.34(e), cylinders and tanks must be
hydrostatically retested
A) once a year by visual inspection
B) a minimum of every 5 years
C) every six months
D) a minimum of once every 2 years - ans -B) a minimum of every 5 years
$21.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Essiekarimi walden
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
19
Miembro desde
1 año
Número de seguidores
2
Documentos
876
Última venta
6 días hace
EXAM ESSENTIALS.

Welcome to your one-stop study hub! Where you Ace your exams with real exam past exams and high quality exam packs. Here you will find : >High quality' A graded study materials that have helped countless students succeed. > Comprehensive exam packs by topic eg pharmacology, Anatomy etc. >Instant downloads for quick and easy prep-anytime and anywhere. >High distinction study guides with answers. SAVE TIME, REDUCE ANXIEXTY AND REVISE WITH CONFIDENCE.

Lee mas Leer menos
4.0

4 reseñas

5
3
4
0
3
0
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes