FLS Exam Questions with Correct
Answers 100% PASS

What are the laparoscope diameters? - CORRECT ANSWER-2-10mm

Which degree scope is best for a field in line with port? - CORRECT ANSWER-0

degree

How to prevent fogging of scope? - CORRECT ANSWER-Use anti fog solution

or put scope in hot water/hot bath

What is the most commonly used light source? - CORRECT ANSWER-300 W

Xenon lamp

What if there is initial low pressure and high flow rate at entry? - CORRECT

ANSWER-Leak in insufflator circuit, make sure everything plugged in correctly

Benefits of monopolar - CORRECT ANSWER-Tissue is heated quickly, less

thermal damage/coagulation

Monopolar voltage/frequency - CORRECT ANSWER-Low voltage/High

frequency

,What does coagulation mode do? - CORRECT ANSWER-Repid surface heating

with shallow depth of necrosis, intermittent wave form with higher voltage

Risk of monopolar - CORRECT ANSWER-Current can be diverted through

unintentional pathways, leading to inadvertent tissue injury. Don't use hybrid ports

that mix metal with plastic

Why do you need a grounding pad for monopolar? - CORRECT ANSWER-

Capacitative coupling - transfer of energy between two conductors separated by an

insulator, transfer to passive electrode. Can release with tissue injury, but no issue

if ground plate is working as capacitor can't store the charge

Benefits of bipolar - CORRECT ANSWER-lower energy, producing less lateral

tissue damage and necrosis. Don't need a grounding pad

Risk of bipolar - CORRECT ANSWER-Risk of cutting patient vessels before

adequate sealing, and device doesn't work if there is metal between the jaws

Risk of ultrasonic dissection (harmonic) - CORRECT ANSWER-Active blade can

injure something due to high frequency (50mHz)

Discontinue aspirin day of surgery? - CORRECT ANSWER-No

How to enter in patient with bowel obstruction? - CORRECT ANSWER-Direct

visualization




COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED

,Cut vs Coag - CORRECT ANSWER-cut - heat tissue quickly to convert cell water

to steam, lysing the cell

Coag - heat more widely dispersed, less cutting action

smaller tissue area, greater current density and faster heating - CORRECT

ANSWER-e.g. Bovie tip

Cut mode - CORRECT ANSWER-- Low voltage

- High frequency

- Continuous waveform

- Heats tissue quickly; cell water converts to steam and causes cell to explode

Coagulation mode - CORRECT ANSWER-- High voltage

- Low frequency

- Intermittent waveform

- Rapid tissue heating, shallow depth of necrosis

- Non-contact: relies on sparking to tissue

Capacitive coupling - CORRECT ANSWER-Transfer current from active

electrode through insulation to passive electrode- electrode to plastic part another

LSC instrument

- if constant contact w/ tissue will not store energy and no injury

, Direct coupling - CORRECT ANSWER-monopolar instrument in direct contact

w/ metal portion of another instrument

Besides capacitative coupling and direct coupling, other hazards of electrocautery -

CORRECT ANSWER-- Current diversion

- Narrow return circuit

Bipolar - CORRECT ANSWER-- forceps w/ two twins (one active other return)

- no pt return electrode required)

- no capacitative coupling

- works in "wet" operative field

- less thermal spread compared to monopolar

bipolar seals vessels up to _____ mm in diameter - CORRECT ANSWER-7 mm

ultrasonic coagulation shears seals vessels up to ____ mm in diameter -

CORRECT ANSWER-5 mm

ultrasonic coagulation shears - CORRECT ANSWER-- combo compression and

friction

- ONE active blade

- monopolar capacity w/ the one blade




COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED
$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
KatelynWhitman West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1106
Miembro desde
2 año
Número de seguidores
482
Documentos
34165
Última venta
2 días hace
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

241 reseñas

5
96
4
39
3
54
2
20
1
32

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes