100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

(3 & 5) HVAC Exam: 2025 Comprehensive Questions & Correct Answers

Puntuación
-
Vendido
-
Páginas
7
Grado
A+
Subido en
04-01-2026
Escrito en
2025/2026

Excel in your HVAC licensing exam with the (3 & 5) HVAC Exam Questions and Correct Answers 2025. This guide provides 100% correct answers to critical industry topics, including heat pump mechanics (converting low-temperature heat to high-temperature heat) and the prevention of evaporator freezing in open-loop systems. Learn essential plumbing and piping standards, such as the three copper tube wall thicknesses (Types K, L, and M) and the use of PE-RT tubing for high-temperature operations. From mastering hydronic valve types like zone, lockshield, and feed water valves to understanding thermal resistance and solar collector arrays, this comprehensive resource is designed to help HVAC professionals achieve an A+ grade.

Mostrar más Leer menos
Institución
Nccco
Grado
Nccco









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Libro relacionado

Escuela, estudio y materia

Institución
Nccco
Grado
Nccco

Información del documento

Subido en
4 de enero de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

3 & 5 HVAC EXAM QUESTIONS WITH
CORRECT ANSWERS 2025
tubing consists of high-
density polyethylene that has undergone molecule modification that creates sufficient tie chains betwee
n the polyethene molecules to allow it to operate at higher temperatures. - CORRECT ANSWER -PE-RT



When water is used as the source fluid for open loop systems, the heat pump must be configured to prev
ent freezing of the . - CORRECT ANSWER -Evaporator



A is a device for converting low-temperature heat into higher temperature heat. -
CORRECT ANSWER -Heat Pump



All solar thermal systems use a to consisting of one or more . - CORRECT ANSWER -
collection array, solar collectors



An objectâ s thermal can be defined as its thickness in the direction of heat flow divided by its ther
mal conductivity. - CORRECT ANSWER -Resistance



In an ideal application, the rate of heatYproduction by the heat source would the rate of heat by the
heat emitters. - CORRECT ANSWER -Exactly match



All heating systems consist of devices that convert one form of energy into another. - CORRECT ANSWER -
True



AYdevice used to allow or prevent flow through a zone circuit is called a(n) . - CORRECT ANSWER -
Zone Valve



A(n) is commonly used to mount an air vent at high points in piping circuits. - CORRECT ANSWER -
Baseboard Tee



Another specialty valve widely used in hydronic systems provides the ability to isolate, flow balance, and
even drain individual heat emitters. It is called a . - CORRECT ANSWER -Lockshield Valve

, Copper water tube is available in three wall thicknesses designated as types in order of decreasing
wall thickness. - CORRECT ANSWER -K, L, and M



Unlike PEX tubing, PEX-AL-
PEX tubing cannot be repaired by heating the tub until the PEX reaches its state. -
CORRECT ANSWER -amorphous



Fittings for copper tubing are available in either wrought copper or . - CORRECT ANSWER -Cast Brass



Feed water valves operate by balancing the force generated by water pressure against an internal flexible
, with the counterforce generated by a partially compressed spring. - CORRECT ANSWER -
Diaphragm



When soldering copper tubing be sure the tube cut is square. Use a(n) with a blade suitable for
the copper tubing. - CORRECT ANSWER -wheel cutter or chop saw



A feed water valve is used to increase the pressure of water from a domestic water distribution pipe befo
re it enters a hydronic system. - CORRECT ANSWER -False



When long straight runs of rigid tubing are required, it may be necessary to install an expansion loop or a
n expansion offset to absorb the movement. Another alternative is to install an expansion capable o
f absorbing the movement. - CORRECT ANSWER -compensator



are designed specifically for component isolation. - CORRECT ANSWER -Gate Valves



Hydronic heating systems should never use a combination of flexible and rigid piping materials. -
CORRECT ANSWER -False



Some common pipe fittings in hydronic systems include . - CORRECT ANSWER -
couplings, elbows, and tees
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
liamcarter
4.0
(1)

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
liamcarter stuvia
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
2 meses
Número de seguidores
0
Documentos
313
Última venta
1 mes hace

4.0

1 reseñas

5
0
4
1
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes