100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

2026 MEDICAL GAS TEST EXAM QUESTIONS COMPLETE SOLUTIONS NEW UPDATE VERIFIED 100%

Puntuación
-
Vendido
-
Páginas
18
Grado
A+
Subido en
30-12-2025
Escrito en
2025/2026

Look at picture #1 - ANSWERSLook at picture #1 A. 6010 - ANSWERSInstallers of a category 1 medical gas piped distribution system must be qualified in accordance with ASSE 6010. What is the certification requirement for installers of a category 3 medical gas piped distribution system? A. 6010 B. 6020 C. 6030 D. Category 3 does NOT require certification A. after blow down of the distribution piping - ANSWERSWhen is the initial pressure test conducted by installer? A. after blow down of the distribution piping

Mostrar más Leer menos
Institución
MEDICAL GAS
Grado
MEDICAL GAS










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
MEDICAL GAS
Grado
MEDICAL GAS

Información del documento

Subido en
30 de diciembre de 2025
Número de páginas
18
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

2026 MEDICAL GAS TEST EXAM
QUESTIONS COMPLETE SOLUTIONS
NEW UPDATE VERIFIED 100%
Look at picture #1 - ANSWERSLook at picture #1

A. 6010 - ANSWERSInstallers of a category 1 medical gas piped distribution system
must be qualified in accordance with ASSE 6010. What is the certification requirement
for installers of a category 3 medical gas piped distribution system?
A. 6010
B. 6020
C. 6030
D. Category 3 does NOT require certification

A. after blow down of the distribution piping - ANSWERSWhen is the initial pressure test
conducted by installer?
A. after blow down of the distribution piping
B. after installation of alarm sensors
C. before blow down of the distribution piping
D. before installation of station rough-in assemblies

C. polymeric - ANSWERSIn those portions of systems intended to handle oxygen at
pressures greater than 350 psi, the interconnecting hose shall NOT contain
__________ materials.
A. brass
B. copper
C. polymeric
D. stainless steel

A. color coding - ANSWERSWhich of these is an NFPA 99 requirement for the labeling
of pipes in a medical gas system?
A. color coding
B. fixed label width
C. label shall wrap completely around the pipe
D. reflective label

D. The device will be supervised such that failure of communication shall initiate an
alarm - ANSWERSA wireless communication device is employed in a medical gas or
vacuum warning system. Which type of supervision is required for this device?
A. A visual indicator shall be located in the maintenance office or the engineering
department.
B. The device shall be installed at the medical gas or vacuum source.
C. The device shall be located at a nurse's station

,D. The device will be supervised such that failure of communication shall initiate an
alarm.

C. 20 feet - ANSWERSPipe labels shall be located at a maximum interval of how many
feet?
A. 10 feet
B. 15 feet
C. 20 feet
D. 25 feet

B. ASSE standard 6010 - ANSWERSThe installation of medical gas and vacuum
systems shall be made by experience, qualified and competent installers. Installers shall
be certified to the requirements of which code/standard?
A. ASME section IX
B. ASSE standard 6010
C. AWS B31.3
D. CGA M-1

C. cutting and/ or brazing new piping - ANSWERSThe removal of components within a
source system for repair and re-installation or for replacement shall be treated as new
work for the purposes of testing whenever such work involves which of the following?
A. air quality monitoring
B. calibration of alarm sensors
C. cutting and/ or brazing new piping
D. system control sensors

B. audible and visual - ANSWERSA medical gas master or area alarm panel should be
set to actuate a(an) _________ indicator when the communication with an alarm-
initiating device is disconnected
A. audible
B. audible and visual
C. high and low
D. visual

A. instrument air - ANSWERSA standard gauge pressure of 160-185 psi applies to
which of the following?
A. instrument air
B. laboratory air
C. laboratory vacuum
D. non-medical air

A. both B and C below

name of the gas and nonstandard operating pressure - ANSWERSWhere medical gas
systems operate at pressures other than the standard gauge pressures, which of these
is required to be listed on the station outlet identification?

, A. both B and C below
B. name of the gas
C. nonstandard operating pressure
D. the gas registration number and a toll-free number to call for information

A. branch (lateral) lines - ANSWERSThose sections or portions of the piping system
that serve a room or group of rooms on the same story of the facility. This is the
definition of which of the following?
A. branch (lateral) lines
B. main lines
C. risers
D. vent lines

B. container - ANSWERSA low-pressure, vacuum-insulated vessel containing gases in
liquid form. This is an NFPA 99 definition for which of the following?
A. appliance
B. container
C. cylinder
D. safety can

B. be appropriately identified by attached labels or stencils in accordance with CGA C-7
criteria - ANSWERSCompressed gas cylinders must meet which of the following criteria
in order to be acceptable for use in an acute health care facility?
A. be appropriately color coded in accordance with U.S.D.A requirements
B. be appropriately identified by attached labels or stencils in accordance with CGA C-7
criteria
C. be constructed in accordance with specifications and regulations of OSHA
D. utilize gas specific CGA connections

A. 23.5% - ANSWERSAccording to the NFPA, an oxygen-enriched atmosphere is one
where the concentration of oxygen exceeds what percentage?
A. 23.5%
D. 25.5%
C. 30%
D. 99%

A. both B and D below

permitted to power medical-surgical tools and used for respiration - ANSWERSWhich of
the following is true of category 1 support gases?
A. both B and D below
B. permitted to power medical-surgical tools
C. subject to greater hazards than present in other piped gases
D. used for respiration
$19.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
shantelleG West Virgina University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
610
Miembro desde
2 año
Número de seguidores
369
Documentos
17855
Última venta
1 semana hace
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.1

115 reseñas

5
69
4
10
3
22
2
2
1
12

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes