Lote
Polysomnography Tests Bundle Set
Polysomnography Tests Bundle Set
[Mostrar más]Polysomnography Tests Bundle Set
[Mostrar más]What is the minimum duration requirement for sleep spindles? CORRECT ANSWER .5 seconds 
 
What is a common complaint immediately following PAP titration? CORRECT ANSWER Nasal dryness and Sneezing 
 
The standard paper speed used for a sleep study is CORRECT ANSWER 10 mm/s 
 
Alpha rhythm during wake...
Vista previa 3 fuera de 30 páginas
Añadir al carritoWhat is the minimum duration requirement for sleep spindles? CORRECT ANSWER .5 seconds 
 
What is a common complaint immediately following PAP titration? CORRECT ANSWER Nasal dryness and Sneezing 
 
The standard paper speed used for a sleep study is CORRECT ANSWER 10 mm/s 
 
Alpha rhythm during wake...
Sleep Technology Review questions with correct answers
Vista previa 3 fuera de 20 páginas
Añadir al carritoSleep Technology Review questions with correct answers
Sleep Technology questions with correct answers
Vista previa 2 fuera de 8 páginas
Añadir al carritoSleep Technology questions with correct answers
American Academy of Sleep medicine CORRECT ANSWER AASM 
 
Apnea Hypopnea index CORRECT ANSWER AHI 
 
Autotitrating Positive Airway Pressure CORRECT ANSWER APAP 
 
Apnea CORRECT ANSWER a pause in breathing during sleep that last at least 10 seconds, in involes a reduction in airflow 90% or more. This...
Vista previa 2 fuera de 7 páginas
Añadir al carritoAmerican Academy of Sleep medicine CORRECT ANSWER AASM 
 
Apnea Hypopnea index CORRECT ANSWER AHI 
 
Autotitrating Positive Airway Pressure CORRECT ANSWER APAP 
 
Apnea CORRECT ANSWER a pause in breathing during sleep that last at least 10 seconds, in involes a reduction in airflow 90% or more. This...
Polysomnography questions with correct answers
Vista previa 2 fuera de 13 páginas
Añadir al carritoPolysomnography questions with correct answers
The standard epoch length used in polysomnography recordings is: CORRECT ANSWER 10mm/sec - 30 sec epoch -or- 
15mm/sec - 20 sec epoch (Neuro) 
 
The initial recording equipment calibration for polysomnography should show: CORRECT ANSWER the filters (high, low and 60Hz) and sensitivity for each chann...
Vista previa 2 fuera de 6 páginas
Añadir al carritoThe standard epoch length used in polysomnography recordings is: CORRECT ANSWER 10mm/sec - 30 sec epoch -or- 
15mm/sec - 20 sec epoch (Neuro) 
 
The initial recording equipment calibration for polysomnography should show: CORRECT ANSWER the filters (high, low and 60Hz) and sensitivity for each chann...
What is a polysomnography? CORRECT ANSWER Sleep study 
 
What part of the brain are we most interested in? CORRECT ANSWER Thalamus, controls consciousness and sleep 
 
What is an electroencephalogram (EEG)? CORRECT ANSWER A measure of electrical activity of the brain recorded across the scalp. 
 
Wh...
Vista previa 3 fuera de 17 páginas
Añadir al carritoWhat is a polysomnography? CORRECT ANSWER Sleep study 
 
What part of the brain are we most interested in? CORRECT ANSWER Thalamus, controls consciousness and sleep 
 
What is an electroencephalogram (EEG)? CORRECT ANSWER A measure of electrical activity of the brain recorded across the scalp. 
 
Wh...
Polysomnogram CORRECT ANSWER Test records several body fuctions during sleep. 
 
Nasion CORRECT ANSWER Bridge of the nose 
 
Inion CORRECT ANSWER Occipital protuberance - most prominent point of the occipital bone 
 
Pre-auricular points CORRECT ANSWER In the front notches in the middle of each ear....
Vista previa 4 fuera de 54 páginas
Añadir al carritoPolysomnogram CORRECT ANSWER Test records several body fuctions during sleep. 
 
Nasion CORRECT ANSWER Bridge of the nose 
 
Inion CORRECT ANSWER Occipital protuberance - most prominent point of the occipital bone 
 
Pre-auricular points CORRECT ANSWER In the front notches in the middle of each ear....
What was the first scoring manual? CORRECT ANSWER R&K Scoring manual 1968 
 
What direction is the pen deflection for negative voltage? CORRECT ANSWER Upward pen deflection 
 
What direction is the pen deflection for positive voltage? CORRECT ANSWER Downward pen deflection 
 
What is the mechanical ...
Vista previa 2 fuera de 10 páginas
Añadir al carritoWhat was the first scoring manual? CORRECT ANSWER R&K Scoring manual 1968 
 
What direction is the pen deflection for negative voltage? CORRECT ANSWER Upward pen deflection 
 
What direction is the pen deflection for positive voltage? CORRECT ANSWER Downward pen deflection 
 
What is the mechanical ...
How many electrodes are in involved in a chin EMG and where are there placed? CORRECT ANSWER 3- one top center and the other two 2 cm down and 2 to the left and 2 cm down a 2 to the right. 
 
EKG led placement has been standardized to which two locations? CORRECT ANSWER Right clavicle and left lower...
Vista previa 1 fuera de 4 páginas
Añadir al carritoHow many electrodes are in involved in a chin EMG and where are there placed? CORRECT ANSWER 3- one top center and the other two 2 cm down and 2 to the left and 2 cm down a 2 to the right. 
 
EKG led placement has been standardized to which two locations? CORRECT ANSWER Right clavicle and left lower...
Vista previa 2 fuera de 9 páginas
Añadir al carritoPolysomnography Study Guide
Where monitor activity with PSG CORRECT ANSWER 2-3 EEG derivations from frontal, central, and occipital regions 
electrode impdances <5 kOhms 
 
EEG measures CORRECT ANSWER postsynaptic potentials from gigantic pyramidal cells 
 
EOG measures CORRECT ANSWER left and right eye movement 
cornea = p...
Vista previa 3 fuera de 17 páginas
Añadir al carritoWhere monitor activity with PSG CORRECT ANSWER 2-3 EEG derivations from frontal, central, and occipital regions 
electrode impdances <5 kOhms 
 
EEG measures CORRECT ANSWER postsynaptic potentials from gigantic pyramidal cells 
 
EOG measures CORRECT ANSWER left and right eye movement 
cornea = p...
Vista previa 4 fuera de 40 páginas
Añadir al carritoPolysomnography Terms
Polysomnography Final Exam questions with correct answers
Vista previa 2 fuera de 7 páginas
Añadir al carritoPolysomnography Final Exam questions with correct answers
Polysomnography questions with correct answers
Vista previa 3 fuera de 17 páginas
Añadir al carritoPolysomnography questions with correct answers
Reduced sleep latency during the MSLT is defined as a mean sleep latency: CORRECT ANSWER LESS than 8 minutes 
 
During a bilevel PAP titration with a setting of 17/13 cm H2O, the patient exhibits two obstructive apneas over the course of 7 minutes. Neither of these events is associated with an arous...
Vista previa 2 fuera de 9 páginas
Añadir al carritoReduced sleep latency during the MSLT is defined as a mean sleep latency: CORRECT ANSWER LESS than 8 minutes 
 
During a bilevel PAP titration with a setting of 17/13 cm H2O, the patient exhibits two obstructive apneas over the course of 7 minutes. Neither of these events is associated with an arous...
American Association of Sleep Technologists CORRECT ANSWER Formerly knows as Association of Polysomnographic Technologists in 1978. 
 
What is the initial mission of AAST? CORRECT ANSWER To unite sleep professionals as a group, offer continuing education, and promote sleep professions at national le...
Vista previa 1 fuera de 4 páginas
Añadir al carritoAmerican Association of Sleep Technologists CORRECT ANSWER Formerly knows as Association of Polysomnographic Technologists in 1978. 
 
What is the initial mission of AAST? CORRECT ANSWER To unite sleep professionals as a group, offer continuing education, and promote sleep professions at national le...
Hans Berger CORRECT ANSWER first to record EEG of humans (1929) 
 
Dr. Nathaniel Kleitman CORRECT ANSWER "father of American sleep research" 
 
REM Sleep CORRECT ANSWER in 1953 important sleep discovery by Kleitman, Aserinky and Dement 
 
Dr. Jerome Holland CORRECT ANSWER Who first coined term pol...
Vista previa 2 fuera de 10 páginas
Añadir al carritoHans Berger CORRECT ANSWER first to record EEG of humans (1929) 
 
Dr. Nathaniel Kleitman CORRECT ANSWER "father of American sleep research" 
 
REM Sleep CORRECT ANSWER in 1953 important sleep discovery by Kleitman, Aserinky and Dement 
 
Dr. Jerome Holland CORRECT ANSWER Who first coined term pol...
To score sleep onset latency the technologist identifies the first... CORRECT ANSWER Epoch of any stage of sleep 
 
The pacemaker of the circadian rhythm is the CORRECT ANSWER SCN 
 
Beta Blockers are known to affect the polysomnography by... CORRECT ANSWER Increasing sleep onset latency and awakeni...
Vista previa 2 fuera de 7 páginas
Añadir al carritoTo score sleep onset latency the technologist identifies the first... CORRECT ANSWER Epoch of any stage of sleep 
 
The pacemaker of the circadian rhythm is the CORRECT ANSWER SCN 
 
Beta Blockers are known to affect the polysomnography by... CORRECT ANSWER Increasing sleep onset latency and awakeni...
Obstructive and central apnea, snoring, childhood sleep apnea, infant sleep apnea 
 
Delayed sleep-wake phase, advanced sleep-wake phase, irregular sleep-wake rhythm, shift work and jet lag 
 
Confusional arousals, sleep walking or talking, sleep terrors, sleep eating disorder, sleep paralysis, nigh...
Vista previa 2 fuera de 6 páginas
Añadir al carritoObstructive and central apnea, snoring, childhood sleep apnea, infant sleep apnea 
 
Delayed sleep-wake phase, advanced sleep-wake phase, irregular sleep-wake rhythm, shift work and jet lag 
 
Confusional arousals, sleep walking or talking, sleep terrors, sleep eating disorder, sleep paralysis, nigh...
There are two types of sleep studies: CORRECT ANSWER 1. Overnight polysomnograms (PSGs) 
2. Daytime nap studies 
 
list the types of overnight polysomnograms: CORRECT ANSWER could be level 1 or 2, seizure montages, CPAP titrations, etc 
 
list the types of daytime nap studies: CORRECT ANSWER multip...
Vista previa 2 fuera de 11 páginas
Añadir al carritoThere are two types of sleep studies: CORRECT ANSWER 1. Overnight polysomnograms (PSGs) 
2. Daytime nap studies 
 
list the types of overnight polysomnograms: CORRECT ANSWER could be level 1 or 2, seizure montages, CPAP titrations, etc 
 
list the types of daytime nap studies: CORRECT ANSWER multip...
Advanced sleep phase syndrome (ASPS) CORRECT ANSWER Cicadian rhythm disorder, phases of daily sleep/wake cycle are advanced with respect to clock time. Sleep phase occurs well ahead of conventional bedtime with tendency to wake up too early; usually involving the elderly 
 
Alpha intrusion CORRECT A...
Vista previa 3 fuera de 24 páginas
Añadir al carritoAdvanced sleep phase syndrome (ASPS) CORRECT ANSWER Cicadian rhythm disorder, phases of daily sleep/wake cycle are advanced with respect to clock time. Sleep phase occurs well ahead of conventional bedtime with tendency to wake up too early; usually involving the elderly 
 
Alpha intrusion CORRECT A...
Polysomnography questions with correct answers
Vista previa 1 fuera de 3 páginas
Añadir al carritoPolysomnography questions with correct answers
Bruxism Scoring CORRECT ANSWER 1. May consist of brief or sustained elevations of chin EMG activity at least twice the amplitude of background EMG. 
2) 0.25 - 2 seconds in duration and if at least 3 elevations in a regular sequece. 
3) sustained elevations of chin EMG if more than 2 seconds. 
4) ...
Vista previa 3 fuera de 20 páginas
Añadir al carritoBruxism Scoring CORRECT ANSWER 1. May consist of brief or sustained elevations of chin EMG activity at least twice the amplitude of background EMG. 
2) 0.25 - 2 seconds in duration and if at least 3 elevations in a regular sequece. 
3) sustained elevations of chin EMG if more than 2 seconds. 
4) ...
What is the system called for electrode placement CORRECT ANSWER 10-20 system 
 
where do the electrodes with odd numbers go on the scalp CORRECT ANSWER left hand side 
 
where do the electrodes with even numbers go on the scalp CORRECT ANSWER right hand side 
 
what does Z stand for CORRECT ANSWER ...
Vista previa 3 fuera de 30 páginas
Añadir al carritoWhat is the system called for electrode placement CORRECT ANSWER 10-20 system 
 
where do the electrodes with odd numbers go on the scalp CORRECT ANSWER left hand side 
 
where do the electrodes with even numbers go on the scalp CORRECT ANSWER right hand side 
 
what does Z stand for CORRECT ANSWER ...
Amplitude correct answer the measure of voltage 
 
Height and speed correct answer amplitude is a measurement of the __________ of a waveform 
Frequency is a measurement of the ______ of a waveform 
 
Microvolts correct answer eeg amplitude is measured in 
 
Hertz correct answer eeg frequency is mea...
Vista previa 3 fuera de 17 páginas
Añadir al carritoAmplitude correct answer the measure of voltage 
 
Height and speed correct answer amplitude is a measurement of the __________ of a waveform 
Frequency is a measurement of the ______ of a waveform 
 
Microvolts correct answer eeg amplitude is measured in 
 
Hertz correct answer eeg frequency is mea...
Essentials of Polysomnography Sample Questions with correct answers
Vista previa 3 fuera de 19 páginas
Añadir al carritoEssentials of Polysomnography Sample Questions with correct answers
What does Stage 1 NREM sleep represent? CORRECT ANSWER Transition from wakefulness to sleep 
 
What would the EEG show during Stage 1 NREM? CORRECT ANSWER Primarily alpha activity with low voltage mixed frequency activity Slow rolling eye movements 
 
What would the EEG show during Stage 2 NREM? COR...
Vista previa 2 fuera de 6 páginas
Añadir al carritoWhat does Stage 1 NREM sleep represent? CORRECT ANSWER Transition from wakefulness to sleep 
 
What would the EEG show during Stage 1 NREM? CORRECT ANSWER Primarily alpha activity with low voltage mixed frequency activity Slow rolling eye movements 
 
What would the EEG show during Stage 2 NREM? COR...
PSG 110 Essentials of Polysomnography questions with correct answers
Vista previa 2 fuera de 6 páginas
Añadir al carritoPSG 110 Essentials of Polysomnography questions with correct answers
Vista previa 3 fuera de 17 páginas
Añadir al carritoPSG 2411 FINAL EXAM SET with correct answers
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller cracker. Stuvia facilitates payment to the seller.
No, you only buy this summary for $45.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now