Lote
NCLE Advanced Exams Questions & Answers Complete Study Guide Bundle with Solutions Graded A+ 2023
NCLE Advanced Exams Questions & Answers Complete Study Guide Bundle with Solutions Graded A+ 2023
[Mostrar más]NCLE Advanced Exams Questions & Answers Complete Study Guide Bundle with Solutions Graded A+ 2023
[Mostrar más]Optic Zone - Central portion of a contact lens which contains the refractive power 
(generally corresponds to the corneal cap) 
Posterior Apecal Radius - Spin-cast soft lenses. (Curvature of posterior surface 
changes with refractive power. Measured at apex of posterior surface) 
Steeper Base Curv...
Vista previa 2 fuera de 5 páginas
Añadir al carritoOptic Zone - Central portion of a contact lens which contains the refractive power 
(generally corresponds to the corneal cap) 
Posterior Apecal Radius - Spin-cast soft lenses. (Curvature of posterior surface 
changes with refractive power. Measured at apex of posterior surface) 
Steeper Base Curv...
1. what medications may affect successful contact lens wear 
Antihistamines are beneficial when treating allergies and cold symptoms 
because they dry out the mucous membranes of the nasal passage. However, 
this may also lead to dehydration of the tear film. Antihistamines have also 
been known ...
Vista previa 2 fuera de 5 páginas
Añadir al carrito1. what medications may affect successful contact lens wear 
Antihistamines are beneficial when treating allergies and cold symptoms 
because they dry out the mucous membranes of the nasal passage. However, 
this may also lead to dehydration of the tear film. Antihistamines have also 
been known ...
The tolerance for the overall lens diameter according to the ANSI standards is: 
A. +/-0.005mm 
B. +/-0.05mm 
C. +/-0.01mm 
D. +/-0.1mm - B. 
According to the ANSI standards (Z80.2-1989), the tolerance for the overall 
diameter of a contat lens is +/-0.05mm. ANSI standards have been developed to ...
Vista previa 3 fuera de 17 páginas
Añadir al carritoThe tolerance for the overall lens diameter according to the ANSI standards is: 
A. +/-0.005mm 
B. +/-0.05mm 
C. +/-0.01mm 
D. +/-0.1mm - B. 
According to the ANSI standards (Z80.2-1989), the tolerance for the overall 
diameter of a contat lens is +/-0.05mm. ANSI standards have been developed to ...
A Correct Statement regarding epithelial cells is that they: 
a)Comprise the posterior layer of the cornea 
b)Are unable to regenerate 
c)Comprise the thickest layer of the cornea 
d) Have the ability to reproduce - d) have the ability to reproduce 
Which of the following prescriptions indicates aga...
Vista previa 3 fuera de 26 páginas
Añadir al carritoA Correct Statement regarding epithelial cells is that they: 
a)Comprise the posterior layer of the cornea 
b)Are unable to regenerate 
c)Comprise the thickest layer of the cornea 
d) Have the ability to reproduce - d) have the ability to reproduce 
Which of the following prescriptions indicates aga...
Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is 
achieved by the use of thea. profile analyzer 
b. shadow graph 
c. keratometer 
d. burton light 
- a. profile analyzer 
Contact lens power should be specified ina. back vertex power 
b. sphero-cylinder power ...
Vista previa 3 fuera de 19 páginas
Añadir al carritoAssessment of the quality of the peripheral curves (blends of a rigid contact lens) is 
achieved by the use of thea. profile analyzer 
b. shadow graph 
c. keratometer 
d. burton light 
- a. profile analyzer 
Contact lens power should be specified ina. back vertex power 
b. sphero-cylinder power ...
optic zone - the central portion of a contact lens which contains the refractive 
power and generally corresponds to the central corneal cap 
posterior apecal radius - this term is generally used in reference to spin-cast soft 
lenses. the curvature of the posterior surface of the lens changes wit...
Vista previa 4 fuera de 45 páginas
Añadir al carritooptic zone - the central portion of a contact lens which contains the refractive 
power and generally corresponds to the central corneal cap 
posterior apecal radius - this term is generally used in reference to spin-cast soft 
lenses. the curvature of the posterior surface of the lens changes wit...
1x vendido
Steep Fluorescein Pattern - Bright green pooling center, very faint green pooling 
on diameter of lens 
Flat Fluorescein Pattern - Bright green pooling on diameter of lens, very faint 
green in center 
Against-the-rule Astigmatism Pattern - Bright green pooling horizontally, faint 
green pooling ...
Vista previa 2 fuera de 11 páginas
Añadir al carritoSteep Fluorescein Pattern - Bright green pooling center, very faint green pooling 
on diameter of lens 
Flat Fluorescein Pattern - Bright green pooling on diameter of lens, very faint 
green in center 
Against-the-rule Astigmatism Pattern - Bright green pooling horizontally, faint 
green pooling ...
Which medication may affect successful contact lens wear? 
- Antihistamines 
Antihistamines are beneficial when treating allergies and cold symptoms because 
they dry out the mucous membranes of the nasal passage. However, this may also 
lead to dehydration of the tear film. Antihistamines have a...
Vista previa 2 fuera de 5 páginas
Añadir al carritoWhich medication may affect successful contact lens wear? 
- Antihistamines 
Antihistamines are beneficial when treating allergies and cold symptoms because 
they dry out the mucous membranes of the nasal passage. However, this may also 
lead to dehydration of the tear film. Antihistamines have a...
The first successful contact lenses which were originally molded to conform to the 
shape of the cornea were known as - Scleral/Haptic lenses 
Corneal contact lenses: - are the most common design for rigid and gas permeable 
lenses. 
The majority of soft lenses fit today are: - semi-scleral 
A liq...
Vista previa 2 fuera de 10 páginas
Añadir al carritoThe first successful contact lenses which were originally molded to conform to the 
shape of the cornea were known as - Scleral/Haptic lenses 
Corneal contact lenses: - are the most common design for rigid and gas permeable 
lenses. 
The majority of soft lenses fit today are: - semi-scleral 
A liq...
Which of the following medications may affect successful contact lens wear? a. 
antacids 
b. antihistamines 
c. aspirin 
d. laxatives - antihistamines 
Which term refers to a sensitivity to light 
A.presbyopia 
B.Photophobia 
C.Pannus 
D. Ptosis - Photophobia 
The following is an example of what ty...
Vista previa 3 fuera de 22 páginas
Añadir al carritoWhich of the following medications may affect successful contact lens wear? a. 
antacids 
b. antihistamines 
c. aspirin 
d. laxatives - antihistamines 
Which term refers to a sensitivity to light 
A.presbyopia 
B.Photophobia 
C.Pannus 
D. Ptosis - Photophobia 
The following is an example of what ty...
What is the mucous membrane that covers the 
sclera and lines the inside of the eyelids? - Conjunctiva 
Which refractive error is commonly referred 
to as "far-sighted"? - Hyperopia 
Which of the following refractive errors results 
in light coming to a point of focus in front of the 
retina? - Hy...
Vista previa 4 fuera de 33 páginas
Añadir al carritoWhat is the mucous membrane that covers the 
sclera and lines the inside of the eyelids? - Conjunctiva 
Which refractive error is commonly referred 
to as "far-sighted"? - Hyperopia 
Which of the following refractive errors results 
in light coming to a point of focus in front of the 
retina? - Hy...
base curve - refers to the radius of curvature of the central posterior surface of the 
lens. It may be expressed in diopters of surface power (D) or in millimeters (mm) 
of radius or curvature. 
optical zone - the chord diameter over which the base curve extends on the 
posterior surface of the ...
Vista previa 2 fuera de 12 páginas
Añadir al carritobase curve - refers to the radius of curvature of the central posterior surface of the 
lens. It may be expressed in diopters of surface power (D) or in millimeters (mm) 
of radius or curvature. 
optical zone - the chord diameter over which the base curve extends on the 
posterior surface of the ...
annular bifocal contact - A lens with distance portion ground into the center of the 
lens and the near portion ground into the periphery 
aphakic lenses - lenses designed for post-cataract fitting 
apical zone of cornea - the central portion of the cornea with a constant radius of 
curvature. Als...
Vista previa 3 fuera de 23 páginas
Añadir al carritoannular bifocal contact - A lens with distance portion ground into the center of the 
lens and the near portion ground into the periphery 
aphakic lenses - lenses designed for post-cataract fitting 
apical zone of cornea - the central portion of the cornea with a constant radius of 
curvature. Als...
which of the following is not important to document in medical records for contact 
lens patients? - location at which the patient was originally taught insertion and 
removal 
which of the following will not increase the movement of a tight fitting rigid gas 
permeable lens? - enlarge the poster...
Vista previa 4 fuera de 257 páginas
Añadir al carritowhich of the following is not important to document in medical records for contact 
lens patients? - location at which the patient was originally taught insertion and 
removal 
which of the following will not increase the movement of a tight fitting rigid gas 
permeable lens? - enlarge the poster...
Which of the following medications may affect successful contact lens wear? 
A. Antacids 
B. Antihistamines 
C. Aspirin 
D. Laxatives 
- B. Antihistimines 
Which term refers to a sensitivity to light? 
A. Prebyopia 
B. Photophobia 
C. Pannus 
D. Ptosis 
- B. Photophobia 
The following is an examp...
Vista previa 2 fuera de 15 páginas
Añadir al carritoWhich of the following medications may affect successful contact lens wear? 
A. Antacids 
B. Antihistamines 
C. Aspirin 
D. Laxatives 
- B. Antihistimines 
Which term refers to a sensitivity to light? 
A. Prebyopia 
B. Photophobia 
C. Pannus 
D. Ptosis 
- B. Photophobia 
The following is an examp...
1. The sagittal depth of a rigid gas permeable contact lens can be altered without 
changing the diameter by: 
A. Changing the power 
B. Changing the edge design 
C. Changing the radius of curvature of the anterior optical zone 
D. Changing the radius of curvature of the posterior optical zone 
- ...
Vista previa 4 fuera de 124 páginas
Añadir al carrito1. The sagittal depth of a rigid gas permeable contact lens can be altered without 
changing the diameter by: 
A. Changing the power 
B. Changing the edge design 
C. Changing the radius of curvature of the anterior optical zone 
D. Changing the radius of curvature of the posterior optical zone 
- ...
The cornea is clear, and must remain clear, which means that it must be _____, 
have regular cell structure, and be free from _______. 
avascular, scarring 
The layers of the cornea from the outermost layer to the innermost layer in order 
are: 
Epithelium 
Bowman's Layer 
Stroma 
Descemet's mem...
Vista previa 3 fuera de 16 páginas
Añadir al carritoThe cornea is clear, and must remain clear, which means that it must be _____, 
have regular cell structure, and be free from _______. 
avascular, scarring 
The layers of the cornea from the outermost layer to the innermost layer in order 
are: 
Epithelium 
Bowman's Layer 
Stroma 
Descemet's mem...
Which of the following medications may affect successful contact lens wear? 
a. antacids 
b. antihistamines 
c. aspirin 
d. laxatives - antihistamines 
Which term refers to a sensitivity to light 
A.presbyopia 
B.Photophobia 
C.Pannus 
D. Ptosis - Photophobia 
The following is an example of what ty...
Vista previa 3 fuera de 28 páginas
Añadir al carritoWhich of the following medications may affect successful contact lens wear? 
a. antacids 
b. antihistamines 
c. aspirin 
d. laxatives - antihistamines 
Which term refers to a sensitivity to light 
A.presbyopia 
B.Photophobia 
C.Pannus 
D. Ptosis - Photophobia 
The following is an example of what ty...
• NCLE Practical broken down based on the ABO-NCLE practical Exam Candidate Handbook Practical Test Specifications sheet
Vista previa 2 fuera de 8 páginas
Añadir al carrito• NCLE Practical broken down based on the ABO-NCLE practical Exam Candidate Handbook Practical Test Specifications sheet
1x vendido
Diffused Illumination – 
-Uses widest slit, longest aperture 
-Light source positioned at an angle of 40º-50º 
-Used to view overall areas, to observe the ocular adnexa, cornea, sclera, lids, 
conjunctiva, lens surface, and CL fitting characteristics 
Direct Illumination – 
-Most important/us...
Vista previa 2 fuera de 10 páginas
Añadir al carritoDiffused Illumination – 
-Uses widest slit, longest aperture 
-Light source positioned at an angle of 40º-50º 
-Used to view overall areas, to observe the ocular adnexa, cornea, sclera, lids, 
conjunctiva, lens surface, and CL fitting characteristics 
Direct Illumination – 
-Most important/us...
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller boomamor2. Stuvia facilitates payment to the seller.
No, you only buy this summary for $30.00. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now