[Mostrar más]When should wet layup be used? 
Select one: 
a. When a boiler may be exposed to freezing conditions. 
b. When a boiler is on standby. 
c. For long term storage. 
d. When desiccant is unavailable. - b 
In a multiple boiler high pressure steam plant, when starting an entire system from cold 
Select on...
Vista previa 2 fuera de 5 páginas
Añadir al carritoWhen should wet layup be used? 
Select one: 
a. When a boiler may be exposed to freezing conditions. 
b. When a boiler is on standby. 
c. For long term storage. 
d. When desiccant is unavailable. - b 
In a multiple boiler high pressure steam plant, when starting an entire system from cold 
Select on...
Chapter (1) 1.Steam is formed when water is heated to its boiling point. - True 
2.A boiler is an open metal container in which water is heated to produce steam or heated water. - 
False 
3.Water begins to boil at 212°F at atmospheric pressure. - True 
4.In a Scotch marine boiler, the gases of comb...
Vista previa 3 fuera de 30 páginas
Añadir al carritoChapter (1) 1.Steam is formed when water is heated to its boiling point. - True 
2.A boiler is an open metal container in which water is heated to produce steam or heated water. - 
False 
3.Water begins to boil at 212°F at atmospheric pressure. - True 
4.In a Scotch marine boiler, the gases of comb...
1 or more safety valves - all steam boilers must have 
Locked closed - before anyone enters the boiler drum, the main steam stop valve, bottom blowdown 
valves, & feedwater valves should be 
212 degrees F - at atmospheric pressure, water begins to boil at approximately 
Fuel oil, gas, & coal - fuels...
Vista previa 2 fuera de 11 páginas
Añadir al carrito1 or more safety valves - all steam boilers must have 
Locked closed - before anyone enters the boiler drum, the main steam stop valve, bottom blowdown 
valves, & feedwater valves should be 
212 degrees F - at atmospheric pressure, water begins to boil at approximately 
Fuel oil, gas, & coal - fuels...
d - The most important rule in safe operation of a steam boiler is to 
a) keep the heat transfer surfaces clean 
b) maintain the boiler room log 
c) try to keep make up water to a minimum 
d) keep water in the boiler at the proper level 
c - in a multiple boiler high pressure steam plant , when star...
Vista previa 3 fuera de 29 páginas
Añadir al carritod - The most important rule in safe operation of a steam boiler is to 
a) keep the heat transfer surfaces clean 
b) maintain the boiler room log 
c) try to keep make up water to a minimum 
d) keep water in the boiler at the proper level 
c - in a multiple boiler high pressure steam plant , when star...
water level on all boilers - When taking over a shift, the boiler operator must first check the _______. 
securing the feed water and allowing the water level in the boiler to drop - The low-water fuel cutoff 
can be tested by blowing down the low-water fuel cutoff or by _____. 
warmed up slowly - I...
Vista previa 1 fuera de 4 páginas
Añadir al carritowater level on all boilers - When taking over a shift, the boiler operator must first check the _______. 
securing the feed water and allowing the water level in the boiler to drop - The low-water fuel cutoff 
can be tested by blowing down the low-water fuel cutoff or by _____. 
warmed up slowly - I...
When taking over a shift, the boiler operator must first check the ___. - water level on all boilers 
The low-water fuel cutoff can be tested by blowing down the low-water fuel cutoff or by ___. - 
securing the feedwater and allowing the water level in the boiler to drop 
In order to prevent uneven ...
Vista previa 1 fuera de 3 páginas
Añadir al carritoWhen taking over a shift, the boiler operator must first check the ___. - water level on all boilers 
The low-water fuel cutoff can be tested by blowing down the low-water fuel cutoff or by ___. - 
securing the feedwater and allowing the water level in the boiler to drop 
In order to prevent uneven ...
If the safety relief valve of a hot water heating boiler is set to open at 207 kPa, the operating pressure 
should not exceed 
Select one: 
a. 52 kPa. 
b. 155 kPa. 
c. 138 kPa. 
d. 207 kPa. - c 
A typical natural gas flame should be 
Select one: 
a. blue, with orange at the tip of the flame 
b. asym...
Vista previa 3 fuera de 25 páginas
Añadir al carritoIf the safety relief valve of a hot water heating boiler is set to open at 207 kPa, the operating pressure 
should not exceed 
Select one: 
a. 52 kPa. 
b. 155 kPa. 
c. 138 kPa. 
d. 207 kPa. - c 
A typical natural gas flame should be 
Select one: 
a. blue, with orange at the tip of the flame 
b. asym...
The number of pounds of steam generated per hour at the pressure and temperature required for all 
purposes to develop contract shaft horsepower of the ship divided by the numbers of boilers installed is 
defined as? - Boiler full power capacity 
Boiler overload capacity is normally what percentage ...
Vista previa 2 fuera de 11 páginas
Añadir al carritoThe number of pounds of steam generated per hour at the pressure and temperature required for all 
purposes to develop contract shaft horsepower of the ship divided by the numbers of boilers installed is 
defined as? - Boiler full power capacity 
Boiler overload capacity is normally what percentage ...
If the safety relief valve of a hot water heating boiler is set to open at 207 kPa, the operating pressure 
should not exceed 
Select one: 
a. 52 kPa. 
b. 155 kPa. 
c. 138 kPa. 
d. 207 kPa. - c 
A typical natural gas flame should be 
Select one: 
a. blue, with orange at the tip of the flame 
b. asym...
Vista previa 3 fuera de 25 páginas
Añadir al carritoIf the safety relief valve of a hot water heating boiler is set to open at 207 kPa, the operating pressure 
should not exceed 
Select one: 
a. 52 kPa. 
b. 155 kPa. 
c. 138 kPa. 
d. 207 kPa. - c 
A typical natural gas flame should be 
Select one: 
a. blue, with orange at the tip of the flame 
b. asym...
If a new boiler is not properly boiled out, it may result in: 
Select one: 
a. furnace explosion 
b. tubes rupturing 
c. a foaming condition occurring 
d. nuisance shut down - c 
An opening from a mechanical room where combustion equipment is housed that provides the fresh air 
required for satisfac...
Vista previa 4 fuera de 48 páginas
Añadir al carritoIf a new boiler is not properly boiled out, it may result in: 
Select one: 
a. furnace explosion 
b. tubes rupturing 
c. a foaming condition occurring 
d. nuisance shut down - c 
An opening from a mechanical room where combustion equipment is housed that provides the fresh air 
required for satisfac...
The number of pounds of steam generated per hour at the pressure and temperature required for all 
purposes to develop contract shaft horsepower of the ship divided by the numbers of boilers installed is 
defined as? - Boiler full power capacity. 
Boiler overload capacity is normally what percentage...
Vista previa 2 fuera de 11 páginas
Añadir al carritoThe number of pounds of steam generated per hour at the pressure and temperature required for all 
purposes to develop contract shaft horsepower of the ship divided by the numbers of boilers installed is 
defined as? - Boiler full power capacity. 
Boiler overload capacity is normally what percentage...
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller PatrickKaylian. Stuvia facilitates payment to the seller.
No, you only buy this summary for $16.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now