Lote
Bundle for CSLB Exams Compilation | Verified | Guaranteed Success
Bundle for CSLB Exams Compilation | Verified | Guaranteed Success
[Mostrar más]Bundle for CSLB Exams Compilation | Verified | Guaranteed Success
[Mostrar más]An employer remits State disability taxes withheld from an employees wages to what 
agency? - Employment Development Department 
Which act establishes the rights of workers to organize into unions and negotiate 
contracts? - National Labor Relations Act of 1935 
A contractor has had a problem with e...
Vista previa 3 fuera de 24 páginas
Añadir al carritoAn employer remits State disability taxes withheld from an employees wages to what 
agency? - Employment Development Department 
Which act establishes the rights of workers to organize into unions and negotiate 
contracts? - National Labor Relations Act of 1935 
A contractor has had a problem with e...
If unused mortar stiffens due to hydration of cement, what must you do? - Discard 
the mortar 
What minimum time must you wait before caulking or grouting new tiles? - 24-48 
Hours 
How long should you wait before installing tile on a shower pan? - 24 Hours 
Unstable dry rock, angular gravel, sandy ...
Vista previa 4 fuera de 31 páginas
Añadir al carritoIf unused mortar stiffens due to hydration of cement, what must you do? - Discard 
the mortar 
What minimum time must you wait before caulking or grouting new tiles? - 24-48 
Hours 
How long should you wait before installing tile on a shower pan? - 24 Hours 
Unstable dry rock, angular gravel, sandy ...
When should you let your attorney see a construction contract? 
A. Before you let the client see the contract 
B. After the contract is prepared but before you sign it 
C. After the building permit is obtained 
D. After the contract is signed by you and the client - B. After the contract is 
prepare...
Vista previa 2 fuera de 10 páginas
Añadir al carritoWhen should you let your attorney see a construction contract? 
A. Before you let the client see the contract 
B. After the contract is prepared but before you sign it 
C. After the building permit is obtained 
D. After the contract is signed by you and the client - B. After the contract is 
prepare...
A ladder should extend a minimum of _____ above the top of a trench or excavation. - 
1' 
According to OSHA, shoring lumber shall be ____. - Select structural 
cal/OSHA inspectors cannot, under most circumstances: - Enter a business outside 
of normal business hours. 
Every employer is required to ...
Vista previa 2 fuera de 9 páginas
Añadir al carritoA ladder should extend a minimum of _____ above the top of a trench or excavation. - 
1' 
According to OSHA, shoring lumber shall be ____. - Select structural 
cal/OSHA inspectors cannot, under most circumstances: - Enter a business outside 
of normal business hours. 
Every employer is required to ...
1x vendido
What is the minimum working clearance from an electrical panel under 600 V? - 36" 
Voltage drop in wire is a function of: - Wire gauge, Length of wire, Current flow in the 
wire 
A 12-volt direct current, 13-watt fluorescent light is controlled by a photocell. The 
average daily on-time is 12 hours...
Vista previa 2 fuera de 8 páginas
Añadir al carritoWhat is the minimum working clearance from an electrical panel under 600 V? - 36" 
Voltage drop in wire is a function of: - Wire gauge, Length of wire, Current flow in the 
wire 
A 12-volt direct current, 13-watt fluorescent light is controlled by a photocell. The 
average daily on-time is 12 hours...
A subcontractor or material supplier has _____ days to file a lien once a notice of 
completion has been recorded.30 
How must a client submit a claim for service or repair of a defect on fit and finish items 
after a remodel?By certified mail 
By overnight mail 
By personal delivery 
A contractor m...
Vista previa 3 fuera de 19 páginas
Añadir al carritoA subcontractor or material supplier has _____ days to file a lien once a notice of 
completion has been recorded.30 
How must a client submit a claim for service or repair of a defect on fit and finish items 
after a remodel?By certified mail 
By overnight mail 
By personal delivery 
A contractor m...
Duct systems should be installed according to ____ Standards - SMACNA 
The type of flue pipe used on gas 80% standard furnace venting systems serving gas 
fired systems - Type B-Vent 
Which type of gauge would you use for very high vacuums? - McLeod type gauge 
How many BTUs are equal to one kilowat...
Vista previa 1 fuera de 2 páginas
Añadir al carritoDuct systems should be installed according to ____ Standards - SMACNA 
The type of flue pipe used on gas 80% standard furnace venting systems serving gas 
fired systems - Type B-Vent 
Which type of gauge would you use for very high vacuums? - McLeod type gauge 
How many BTUs are equal to one kilowat...
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Tulloch. Stuvia facilitates payment to the seller.
No, you only buy this summary for $30.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now