Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY QUESTIONS WITH REVISED ANSWERS NEW UPDATE GUARANTEED PASS | RATED A+

Puntuación
-
Vendido
-
Páginas
11
Grado
A+
Subido en
29-12-2024
Escrito en
2024/2025

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY QUESTIONS WITH REVISED ANSWERS NEW UPDATE GUARANTEED PASS | RATED A+ A pathway shall be designated as Class when it does not include a redundant path and operational capability stops at a single open and operational capability is maintained during the application of a single ground fault? - Answer Class B EMT shall be securely fastened in place at least every feet. - Answer 10 feet The minimum clear safe working distance from an energized 240 volt breaker panel that has the cover removed is ft from the wall in front the panel. - Answer 3 feet Wall mounted audible appliances shall have their tops above the finished floors at heights of not less than inches and below the finished ceilings at distances of not less than 6 inches? - Answer 90 inches A minimum db ambient sound level with a 6 hour exposure time requires hearing protection? - Answer 92 db Ground fault circuit interrupters are required for all 120 volts power tools on a construction site unless . - Answer The work area is dry Consider the use of a multimeter in troubleshooting a fire alarm circuit. The circuit has an end of the line resistor with a value of 4.7ohms. With the circuit disconnected from power, the positive leg of a fire alarm circuit is metered to a known ground with the meter set to the 10kohm setting. Consider that the circuit is properly functioning. The expected reading on the multimeter is ohms? - Answer Infinity Including new systems and addition or alterations to existing systems, which of the following is not required to be delivered to the owner upon final acceptance of the system? - Answer Inspection & Testing records, Central station history log According to NFPA 72, section of the record of completion is used to note the input voltage? - Answer Section 5.1.11 Which of the following is not one of the criteria to be a designated a confined space? - Answer A room that locks when the door is closed. According to NFPA 72 the onsite location of the required record documents and specific software is notes in section of the Record of Completion? - Answer Section 3 According to NFPA 72 the Record of Completion section 12.1 is required to be signed by ? - Answer System Installation Contractor

Mostrar más Leer menos
Institución
NICET LEVEL 1 FIRE ALARM SYSTEMS
Grado
NICET LEVEL 1 FIRE ALARM SYSTEMS

Vista previa del contenido

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY
QUESTIONS WITH REVISED ANSWERS NEW UPDATE
GUARANTEED PASS | RATED A+

A pathway shall be designated as Class when it does not include a redundant path and
operational capability stops at a single open and operational capability is maintained during the
application of a single ground fault? - Answer>>> Class B

EMT shall be securely fastened in place at least every feet. - Answer>>> 10 feet
The minimum clear safe working distance from an energized 240 volt breaker panel that has
the cover removed is ft from the wall in front the panel. - Answer>>> 3 feet
Wall mounted audible appliances shall have their tops above the finished floors at heights of
not less than inches and below the finished ceilings at distances of not less than 6 inches?
- Answer>>> 90 inches

A minimum db ambient sound level with a 6 hour exposure time requires hearing
protection? - Answer>>> 92 db

Ground fault circuit interrupters are required for all 120 volts power tools on a construction site
unless . - Answer>>> The work area is dry

Consider the use of a multimeter in troubleshooting a fire alarm circuit. The circuit has an end
of the line resistor with a value of 4.7ohms. With the circuit disconnected from power, the
positive leg of a fire alarm circuit is metered to a known ground with the meter set to the
10kohm setting. Consider that the circuit is properly functioning. The expected reading on the
multimeter is ohms? - Answer>>> Infinity

Including new systems and addition or alterations to existing systems, which of the following is
not required to be delivered to the owner upon final acceptance of the system? - Answer>>>
Inspection & Testing records, Central station history log

According to NFPA 72, section of the record of completion is used to note the input voltage? -
Answer>>> Section 5.1.11

Which of the following is not one of the criteria to be a designated a confined space? -
Answer>>> A room that locks when the door is closed.

, According to NFPA 72 the onsite location of the required record documents and specific
software is notes in section of the Record of Completion? - Answer>>> Section 3

According to NFPA 72 the Record of Completion section 12.1 is required to be signed
by ? - Answer>>> System Installation Contractor

What is the minimum size grounding conductor that cab be used when wiring a fire alarm
control panel to a 20 amp. Breaker? - Answer>>> #12

The location of the branch circuit overcurrent protective device shall be permanently identified
at the fire alarm control unit . Which of the following is a requirement of the circuit
disconnecting means? Select Three - Answer>>> 1.Red identification 2.Accessible only to
qualified personnel 3.Identified as FIRE ALARM CIRCUIT

The secondary power supply should automatically provide power to protect premises system
within seconds Whenever the primary power supply voltage is insufficient for required
systems operation. - Answer>>> 10 seconds

Consider a fire alarm system which does not use an uninterruptible power supply for primary
power. Independent and reliable power supply shall be provided? - Answer>>> 2
independent

You are using a power tool that has a 3 prong (grounded) plug. The only outlets available are 2
prong (non grounded). What can be done? - Answer>>> Locate a 3 prong plug or used a tool
with a 2 prong plug.

The power source for a power limited fire alarm circuit shall be a listed PLFA or Class
transformer? - Answer>>> Class 3 transformer

Which of the following is a symptom of heat stroke? - Answer>>> Red skin, Elevated Body
Temperature, Rapid, Weak pulse

The maximum number of 14 AWG, RHH conductors permitted in 1/2 inch EMT is ?-
Answer>>> 4

The distance between smoke detectors shall not exceed a nominal spacing of feet? -
Answer>>> 30 feet

A portable ladder shall support at least times the maximum intended load. - Answer>>>

Escuela, estudio y materia

Institución
NICET LEVEL 1 FIRE ALARM SYSTEMS
Grado
NICET LEVEL 1 FIRE ALARM SYSTEMS

Información del documento

Subido en
29 de diciembre de 2024
Número de páginas
11
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

13,99 €
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EXCELLENCE8HUB Chamberlain School Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
63
Miembro desde
3 año
Número de seguidores
17
Documentos
1597
Última venta
1 día hace
Home of Test Banks , Flash cards, Notes, Exam (elaborations)Questions and Answers.

On this page you find all latest quality Test Banks, Flashcards, notes and examinations (elaborations) you can easily acquire at any place of interest at any comfortable time .Build your knowledge at MED EXCELLENCE HUB. Thank you for your reviews. Growth in knowledge is growth in our future.

4,3

13 reseñas

5
10
4
1
3
0
2
0
1
2

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

¿Trabajando en tus referencias?

Crea citas precisas en APA, MLA y Harvard con nuestro generador de citas gratuito.

¿Trabajando en tus referencias?

Preguntas frecuentes