ASRT modules review UPDATED ACTUAL Questions and CORRECT Answers Helical scanning motion was first made possible by the unique construction of the ____________ scanner. A) fourth generation B) fifth generation C) sixth generation D) seventh generation - CORRECT ANSWER - 7th The type of beam geometry used in modern CT scanners is called: A) fan beam. B) wide beam. C) pencil beam. D) cone beam. - CORRECT ANSWER - cone beam

Mostrar más Leer menos
Institución
ASRT
Grado
ASRT










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ASRT
Grado
ASRT

Información del documento

Subido en
24 de diciembre de 2024
Número de páginas
22
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ASRT modules review UPDATED ACTUAL
Questions and CORRECT Answers
Helical scanning motion was first made possible by the unique construction of the
____________ scanner.
A) fourth generation B) fifth generation C) sixth generation D) seventh generation - CORRECT
ANSWER - 7th


The type of beam geometry used in modern CT scanners is called:

A) fan beam. B) wide beam. C) pencil beam. D) cone beam. - CORRECT ANSWER -
cone beam


The ___________ method of data acquisition gathers image data in distinct sections and is
sometimes describes as having a "start/stop" motion.

A) spiral B) sequential C) helical D) volume - CORRECT ANSWER - sequential


When pitch is less than 1, the resulting bands of data are:

A) adjacent. B) distinct. C) overlapped. D) gapped - CORRECT ANSWER - overlapping


Which of the following is not a component of the CT gantry?
A) X-ray tube B) Array processor C) Slip rings D) Digital acquisition system - CORRECT
ANSWER - array processor


Detector systems in which the elements are not all the same size are referred to as:
A) adaptive arrays. B) volumetric arrays. C) symmetric arrays. D) unbalanced arrays. -
CORRECT ANSWER - adaptive arrays


All of the following are characteristics of beam-shaping filters, except:
A) they are physical devices.
B) they change the spatial distribution of the beam.

,C) they change the digital appearance of images.

D) they remove lower-energy x-rays from the beam. - CORRECT ANSWER - they change
digital appearance of images


The primary data processing component of the CT system is the:
A) array processor. B) digital acquisition system. C) PACS. D) amplifier. - CORRECT
ANSWER - array processor


An increase in pitch also results in increased:

A) patient dose. B) scan speed. C) image quality. D) scan length. - CORRECT ANSWER -
scan speed


The largest piece of the CT device is called:

A) the gantry. B) the processor. C) the housing. D) the ring. - CORRECT ANSWER -
gantry


When considering detector efficiency, the measure of how consistently the detectors respond is
called:
A) capture efficiency. B) absorption efficiency. C) stability. D) response time. - CORRECT
ANSWER - stability


Which component of the CT gantry supplies electrical power to the x-ray tube and transfers the
signals from the detectors to the computer?
A) Generator B) Slip rings C) Photomultiplier D) Data acquisition system - CORRECT
ANSWER - slip rings


The first generation CT scan pattern was called _______ acquisition.

A) translate and rotate B) step-and-shoot C) helical D) linear - CORRECT ANSWER -
translate and rotate

, Which of the following is false regarding conventional axial scanning compared to helical
scanning?
A) Axial scanning requires more contrast media.
B) Axial scanning has greater potential for misalignment between scans.
C) Axial scanning is more sensitive to patient motion.

D) Axial scanning results in poorer image quality. - CORRECT ANSWER - more sensitive
to patient motion


The number of detectors the scanner uses to collect data for a particular scan is determined by
the:
A) scan field of view. B) display field of view. C) pitch. D) slice thickness. - CORRECT
ANSWER - SFOV


Using a wider display field of view results in:
A) reduced noise. B) improved spatial resolution. C) anatomy appearing larger. D) increased
patient dose. - CORRECT ANSWER - reduced noise


The depth of a voxel is determined by the:

A) field of view. B) slice thickness. C) matrix size. D) pixel size. - CORRECT ANSWER -
slice thickness


The range of CT numbers displayed in the reconstructed image is controlled by:
A) subject contrast. B) inherent contrast C) window width. D) window level. - CORRECT
ANSWER - window width


All of the following types of exams typically use a large SFOV, except for:
A) chest exams. B) spine exams. C) extremity exams. D) skull exams. - CORRECT
ANSWER - skull


Matrix size never changes, but the pixel size can vary based on the selected: A) scan field of
view. B) pitch. C) kVp. D) mAs. - CORRECT ANSWER - SFOV
10,48 €
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1074
Miembro desde
1 año
Número de seguidores
102
Documentos
68976
Última venta
2 días hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3,8

170 reseñas

5
73
4
30
3
45
2
8
1
14

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes