100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

ASRT MAMMOGRAPHY MODULE UPDATED ACTUAL Questions and CORRECT Answer

Puntuación
-
Vendido
-
Páginas
31
Grado
A+
Subido en
24-12-2024
Escrito en
2024/2025

ASRT MAMMOGRAPHY MODULE UPDATED ACTUAL Questions and CORRECT Answers Using kVp settings of 20 to 40 creates a lower-energy x-ray beam that results in increased: 1. Scatter Radiation 2. Radiographic Contrast 3. Radiation Dose A. 1 and 2 B. 1 and 3 C. 2 and 3 D. 1, 2, and 3 - CORRECT ANSWER - C. 2 and

Mostrar más Leer menos
Institución
ASRT
Grado
ASRT











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ASRT
Grado
ASRT

Información del documento

Subido en
24 de diciembre de 2024
Número de páginas
31
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ASRT MAMMOGRAPHY MODULE
UPDATED ACTUAL Questions and
CORRECT Answers
Using kVp settings of 20 to 40 creates a lower-energy x-ray beam that results in increased:
1. Scatter Radiation 2. Radiographic Contrast 3. Radiation Dose
A. 1 and 2
B. 1 and 3
C. 2 and 3

D. 1, 2, and 3 - CORRECT ANSWER - C. 2 and 3


All of the following are types of filter materials used in mammography, except:
A) molybdenum.
B) rhodium.
C) silver.

D) tungsten. - CORRECT ANSWER - D. Tungsten


Mammography x-ray tubes are oriented so that the strongest part of the x-ray beam is directed to
the patient's:
A. nipple side
B. chest wall side
C. lateral side

D. medial side - CORRECT ANSWER - B. chest wall side


The focal spot sizes used in mammography range between ______ and _____mm.
A. 0.1;0.3
B. 0.3;0.6
C. 0.6;0.9

,D. 0.9;1.2 - CORRECT ANSWER - A. 0.1;0.3


Manual technique are used instead of automatic exposure only when the patient has:
A. dense breast
B. fatty breast
C. a palpable lump

D. breast implants - CORRECT ANSWER - D. breast implants


Which of the following are benefits of using compression in mammography?
1. Increased spatial resolution 2. Uniform radiation exposure 3. Decreased tissue overlap
A. 1 and 2
B. 1 and 3
C. 2 and 3

D. 1, 2, and 3 - CORRECT ANSWER - D. 1, 2, and 3


Which of the following is not a standard function of a picture archiving and communication
system (PACS)?
A. image acquisition
B. image transfer
C. image evaluation

D. image management - CORRECT ANSWER - C. image evaluation


The ACR mammography phantom contains a wax insert that simulates ______cm of breast
tissue.
A. 2.2
B. 3.4
C. 4.2

D. 5.4 - CORRECT ANSWER - C. 4.2

,Which of the following is not a requirement for mammographers under MQSA?
A. passing a criminal background check
B. holding a state license
C. completing 40 hours of mammography instruction

D. performing 200 mammograms every 2 years - CORRECT ANSWER - A. passing a
criminal background check


Diagnostic mammography is used to confirm a diagnosis of breast cancer.
A. True

B. False - CORRECT ANSWER - B. False


________ is especially useful in determining whether a lesion is a solid mass or a fluid-filled
cyst.
A. breast ultrasound
B. breast MR
C. breast-specific gamma imaging

D. digital breast tomosynthesis - CORRECT ANSWER - A. breast ultrasound


A major disadvantage of _________ in breast evaluation is the high false-positive rate from the
exams.
A. digital breast tomosynthesis
B. ultrasound
C. magnetic resonance (MR) imaging

D. molecular imaging - CORRECT ANSWER - C. magnetic resonance (MR) imaging


A milliamperage setting of _____mA is outside of the normal output range of a typical
mammography unit.
A. 20

, B. 40
C. 100

D. 200 - CORRECT ANSWER - D. 200


An interaction with an atom's ______ is most likely to result in photoelectric absorption.
A. K-shell
B. L-shell
C. M-shell

D. N-shell - CORRECT ANSWER - A. K-shell


Compared to molybdenum, rhodium is less desirable for routine use as a mammography target
material because rhodium:
A. has a lower k-edge
B. produces more low-energy bremsstrahlung photons
C. has a higher heat load capacity

D. produces fewer characteristic photons - CORRECT ANSWER - B. produces more low-
energy bremsstrahlung photons


The total filtration requirement of a mammographic tube operating at 30 kVp must be
______mm aluminum (Al) equivalent.
A. 0.25
B. 0.30
C. 0.35

D. 0.40 - CORRECT ANSWER - B. 0.30


To compensate for the relatively short source-to-image distance (SID) used in mammography,
dedicated mammography equipment takes advantage of:
A. the anode heel effect
B. a longer object-to-image distance (OID)
9,17 €
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1074
Miembro desde
1 año
Número de seguidores
102
Documentos
68976
Última venta
2 días hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3,8

170 reseñas

5
73
4
30
3
45
2
8
1
14

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes