100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

ARDMS practice test questions and answers

Puntuación
-
Vendido
-
Páginas
16
Grado
A
Subido en
01-11-2024
Escrito en
2024/2025

Sonographers should be aware of work-related musculoskeletal disorders. Best practice while scanning is to avoid abducting the arm more than how many degrees? a. 50 b. 90 c. 30 d. 40 -Correct Answer c. 30 Which action demonstrates best practice during ultrasound exams regarding the ALARA principle? a. The exposure time should be extended during the exam. b. use the lowest possible output power that provides a diagnostic image. c. use the lowest possible gain. d. Ensure that the time gain compensation (TGC is within acceptable limits. -Correct Answer b. use the lowest possible output power that provides a diagnostic image Which type of cavitation is the most concerning cause of bioeffects? a. Transient b. Absorption c. Stable d. Thermal -Correct Answer a. transient Assuming an unfocused ultrasound beam, the American Institute of ultrasound in Medicine's "statement on Mammalian Biological Effects of ultrasound In vivo" has confirmed that no bioeffects have been noted when the spatial pulse temporal average (SPTA) intensity is less than which value? a. 1 mW/cm2 b. 100 W/cm2 c. 1 W/cm2 d. 100 mW/cm2 -Correct Answer d. 100 mW/cm2 A sonographer notices that the mechanical index (MI) is too high during an ultrasound. What would be the MOST appropriate modification that the sonographer can make? a. decrease receiver gain b. increase period c. decrease the output power d. decrease the frequency of the transducer -Correct Answer c. decrease the output power Select the technique that will generate the LEAST amount of exposure to the patient. a. Spectral Doppler b. Color flow Doppler c. Grayscale d. M-mode -Correct Answer c. grayscale When a vibrating string or fluid pump is used to test system performance, what parameter is being tested? a. Dead zone b. Doppler velocities c. Contrast resolution d. Grayscale sensitivity -Correct Answer b. Doppler velocities A tissue-equivalent phantom is used to ensure the efficiency of the ultrasound machine. Choose the resolution that is NOT tested with this phantom. a. Temporal b. Contrast c. Axial d. Horizontal -Correct Answer a. temporal Which performance check describes the ability of the ultrasound machine to correctly visualize signals that are weaker than others? a. Accuracy b. Specificity c. Reliability d. Sensitivity -Correct Answer d. sensitivity What is the name of the recent technological advancement that is used on tissues such as the liver, breast, prostate, and thyroid to assess the stiffness of tissue or to better assess lesions? a. Contrast-enhanced ultrasound b. Fusion imaging c. Elastography d. Harmonics -Correct Answer c. elastography Which choice is NOT a true statement regarding this filling defect within the gallbladder? a. The filling defect displays a significant amount of attenuation. b. it has created an enhancement artifact. c. It has created a shadowing artifact d. Regions deeper than the filling defect are obscured. -Correct Answer b. it has created an enhancement artifact Which type of artifact appears echogenic and stems from gas bubbles as they vibrate due to the interaction with the ultrasound beam? a. Ring-down artifact b. edge shadow c. Crosstalk d. Slice thickness -Correct Answer a. ring-down artifact

Mostrar más Leer menos
Institución
ARDMS .
Grado
ARDMS .










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ARDMS .
Grado
ARDMS .

Información del documento

Subido en
1 de noviembre de 2024
Número de páginas
16
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ARDMS Abdomen Exam



ARDMS practice test questions and
answers 2024-2025
Sonographers should be aware of work-related musculoskeletal disorders. Best practice
while scanning is to avoid abducting the arm more than how many degrees?
a. 50
b. 90
c. 30
d. 40 -Correct Answer ✔c. 30

Which action demonstrates best practice during ultrasound exams regarding the ALARA
principle?
a. The exposure time should be extended during the exam.
b. use the lowest possible output power that provides a diagnostic image.
c. use the lowest possible gain.
d. Ensure that the time gain compensation (TGC is within acceptable limits. -Correct
Answer ✔b. use the lowest possible output power that provides a diagnostic image

Which type of cavitation is the most concerning cause of bioeffects?
a. Transient
b. Absorption
c. Stable
d. Thermal -Correct Answer ✔a. transient

Assuming an unfocused ultrasound beam, the American Institute of ultrasound in
Medicine's "statement on Mammalian Biological Effects of ultrasound In vivo" has
confirmed that no bioeffects have been noted when the spatial pulse temporal average
(SPTA) intensity is less than which value?
a. 1 mW/cm2
b. 100 W/cm2
c. 1 W/cm2
d. 100 mW/cm2 -Correct Answer ✔d. 100 mW/cm2

A sonographer notices that the mechanical index (MI) is too high during an ultrasound.
What would be the MOST appropriate modification that the sonographer can make?
a. decrease receiver gain
b. increase period
c. decrease the output power
d. decrease the frequency of the transducer -Correct Answer ✔c. decrease the output
power

Select the technique that will generate the LEAST amount of exposure to the
patient.
a. Spectral Doppler


ARDMS Abdomen Exam

,ARDMS Abdomen Exam


b. Color flow Doppler
c. Grayscale
d. M-mode -Correct Answer ✔c. grayscale

When a vibrating string or fluid pump is used to test system performance,
what parameter is being tested?
a. Dead zone
b. Doppler velocities
c. Contrast resolution
d. Grayscale sensitivity -Correct Answer ✔b. Doppler velocities

A tissue-equivalent phantom is used to ensure the efficiency of the
ultrasound machine. Choose the resolution that is NOT tested with this
phantom.
a. Temporal
b. Contrast
c. Axial
d. Horizontal -Correct Answer ✔a. temporal

Which performance check describes the ability of the ultrasound machine
to correctly visualize signals that are weaker than others?
a. Accuracy
b. Specificity
c. Reliability
d. Sensitivity -Correct Answer ✔d. sensitivity

What is the name of the recent technological advancement that is used on tissues such
as the liver, breast, prostate, and thyroid to assess the stiffness of tissue or to better
assess lesions?
a. Contrast-enhanced ultrasound
b. Fusion imaging
c. Elastography
d. Harmonics -Correct Answer ✔c. elastography

Which choice is NOT a true statement regarding this filling defect within the gallbladder?
a. The filling defect displays a significant amount of attenuation.
b. it has created an enhancement artifact.
c. It has created a shadowing artifact
d. Regions deeper than the filling defect are obscured. -Correct Answer ✔b. it has
created an enhancement artifact

Which type of artifact appears echogenic and stems from gas bubbles as they vibrate
due to the interaction with the ultrasound beam?
a. Ring-down artifact
b. edge shadow
c. Crosstalk

ARDMS Abdomen Exam

, ARDMS Abdomen Exam


d. Slice thickness -Correct Answer ✔a. ring-down artifact

What is the fundamental reason that the power and intensity of the ultrasound beam
diminish as it travels through tissue?
a. Absorption
b. Cavitation
c. Obstruction
d. Acoustic impedance -Correct Answer ✔a. absorption

Select the modification that the sonographer can make to decrease the amount of
attenuation as the ultrasound beam travels through tissues.
a. Increase the imaging depth.
b. Increase the frequency of the transducer.
c. Decrease the output power.
d. Decrease the frequency of the transducer. -Correct Answer ✔d. decrease the
frequency of the transducer

Choose the ultrasound system function that enables the sonographer to
adapt to the amount of attenuation that occurs with increasing depth.
a. Focusing
b. Receiver gain
c. TGC
d. Output power -Correct Answer ✔c. TGC

Assume that a sound beam is traveling in soft tissue. Calculate the
attenuation coefficient if the frequency is 12 MHz.
a. 12dB/cm
b. 6 dB/cm
c. 8 dB/cm
d. 10 dB/cm -Correct Answer ✔b. 6 dB/cm

What is NOT a component of attenuation?
a. Reflection
b. Scattering
c. Resolution
d. Absorption -Correct Answer ✔c. resolution

Impedance is NOT influenced by which component?
a. The frequency of the transducer
b. Density
c. Propagation speed
d. Stiffness -Correct Answer ✔a. the frequency of the transducer

For reflection to take place, which situation must exist?
a. The border of two different tissues must have different impedances.


ARDMS Abdomen Exam
13,18 €
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PossibleA Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
985
Miembro desde
4 año
Número de seguidores
650
Documentos
12644
Última venta
13 horas hace
POSSIBLEA QUALITY UPDATED EXAMS

Choose quality study materials for nursing schools to ensure success in your studies and future career. "Welcome to PossibleA - your perfect study assistant! Here you will find Quality sheets, study materials, exams, quizzes, tests, and notes to prepare for exams and study successfully. Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers and checked for quality. Our quality sheets are an easy and quick way to remember key points and definitions. And our study materials, tests, and quizzes will help you absorb the material and prepare for exams. Our store also has notes and lecture summaries that will help you save time and make the learning process more efficient.

Lee mas Leer menos
3,9

141 reseñas

5
74
4
25
3
20
2
1
1
21

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes