100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

APWA Certified Public Infrastructure Inspector (CPII) Practice Exam

Puntuación
2,0
(1)
Vendido
3
Páginas
139
Grado
A+
Subido en
07-10-2024
Escrito en
2024/2025

The APWA CPII Practice Exam is designed for individuals involved in public infrastructure inspection. It covers inspection processes for roads, bridges, utilities, and other public works projects. Topics include construction standards, material testing, safety regulations, and project documentation. Candidates are assessed on their ability to ensure compliance with government codes, manage project timelines, and ensure quality control.

Mostrar más Leer menos
Institución
Computers
Grado
Computers











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Computers
Grado
Computers

Información del documento

Subido en
7 de octubre de 2024
Número de páginas
139
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

APWA Certified Public Infrastructure Inspector (CPII)



1. Which of the following documents provides guidelines for constructing storm
sewers?
o A) Environmental Impact Report
o B) Construction Specifications
o C) Safety Manual
o D) Maintenance Schedule

Answer: B) Construction Specifications
Explanation: Construction Specifications outline the requirements for constructing
storm sewers, including materials, methods, and standards.

2. When inspecting water systems, what is a key aspect to verify?
o A) Aesthetic appearance
o B) Construction materials and installation methods
o C) Landscaping around the system
o D) Lighting in the vicinity

Answer: B) Construction materials and installation methods
Explanation: Ensuring that construction materials and installation methods adhere to
specifications is crucial for the integrity of the water system.

3. What type of plans is essential for inspecting sanitary sewers?
o A) Electrical plans
o B) Architectural plans
o C) Plumbing plans
o D) Civil engineering plans

Answer: D) Civil engineering plans
Explanation: Civil engineering plans provide detailed information on the
construction and placement of sanitary sewers.

4. In inspecting utility systems, which aspect is NOT typically reviewed?
o A) Construction methods
o B) Future maintenance schedules
o C) Compliance with specifications
o D) Utility system performance under stress

Answer: B) Future maintenance schedules
Explanation: While inspecting utility systems focuses on compliance with current
specifications and construction methods, future maintenance schedules are typically
outside the scope of inspection.

5. What should be verified for backfill material used in trench excavation?
o A) Color and texture
o B) Compliance with approved plans
o C) Availability from local suppliers
o D) Cost-effectiveness



1

, APWA Certified Public Infrastructure Inspector (CPII)



Answer: B) Compliance with approved plans
Explanation: Backfill material must meet the specifications outlined in the approved
plans to ensure stability and proper support.

6. When inspecting manholes, what is an essential feature to check?
o A) Surface finish
o B) Proper sealing and alignment
o C) Manufacturer's logo
o D) Installation date

Answer: B) Proper sealing and alignment
Explanation: Proper sealing and alignment are critical to prevent leaks and ensure the
structural integrity of manholes.

7. Which of the following is a primary concern when inspecting valves?
o A) Valve color
o B) Accessibility and operability
o C) Manufacturer's warranty
o D) Installation cost

Answer: B) Accessibility and operability
Explanation: Ensuring that valves are accessible and functional is essential for
maintaining and operating the utility system effectively.

8. What must be checked for pipes used in underground construction?
o A) Color and branding
o B) Diameter and material compliance
o C) Price and supplier reputation
o D) Historical performance

Answer: B) Diameter and material compliance
Explanation: The diameter and material of pipes must comply with the specifications
to ensure proper function and durability.

9. What is a key consideration when inspecting utility installation in a trenchless
method?
o A) Surface appearance
o B) Depth and alignment accuracy
o C) Landscaping around the site
o D) Construction crew's uniform

Answer: B) Depth and alignment accuracy
Explanation: Ensuring that the installation is at the correct depth and alignment is
crucial for the functionality and safety of trenchless utility installations.

10. During the inspection of utility taps, what should be verified?
o A) Tap color
o B) Correct size and secure connection


2

, APWA Certified Public Infrastructure Inspector (CPII)



o C) Availability of taps in stock
o D) Cost of the taps

Answer: B) Correct size and secure connection
Explanation: The size and secure connection of utility taps must be verified to ensure
proper function and prevent leaks.

11. What is important to check during trench backfill inspections?
o A) Backfill material aesthetics
o B) Proper compaction and material type
o C) Backfill cost
o D) Vendor reputation

Answer: B) Proper compaction and material type
Explanation: Proper compaction and the correct type of material are crucial for the
stability and safety of backfilled trenches.

12. When inspecting discontinued or interrupted services, what should be verified?
o A) Service provider's schedule
o B) Safe and proper capping or sealing
o C) Service fees
o D) Historical service issues

Answer: B) Safe and proper capping or sealing
Explanation: Discontinued or interrupted services need to be properly capped or
sealed to prevent hazards and ensure safety.

13. What is the purpose of a mandrel test in sewer infrastructure?
o A) To measure the pipe's internal diameter
o B) To test the pipe's resistance to pressure
o C) To inspect the pipe's alignment and deflection
o D) To verify the pipe's resistance to chemicals

Answer: C) To inspect the pipe's alignment and deflection
Explanation: A mandrel test is used to ensure that pipes are properly aligned and not
excessively deflected.

14. Which test is used to measure the air-tightness of a sewer pipe?
o A) Vacuum test
o B) Mandrel test
o C) Infiltration test
o D) Chlorine residual test

Answer: A) Vacuum test
Explanation: The vacuum test measures the air-tightness of sewer pipes to ensure
there are no leaks.

15. What does a video inspection of sewer lines typically assess?

3

, APWA Certified Public Infrastructure Inspector (CPII)



o A) Pipe material and color
o B) Internal condition and blockages
o C) Pipe installation cost
o D) Surface appearance of the pipes

Answer: B) Internal condition and blockages
Explanation: Video inspections are used to assess the internal condition of sewer
lines and identify any blockages or issues.

16. In an infiltration/exfiltration test, what is being measured?
o A) The flow rate of water into or out of a sewer system
o B) The color change in the pipe material
o C) The pipe's resistance to external pressure
o D) The temperature of the sewer system

Answer: A) The flow rate of water into or out of a sewer system
Explanation: Infiltration/exfiltration tests measure the amount of water entering or
exiting the sewer system to detect leaks or infiltration issues.

17. What is the primary purpose of hydrostatic pressure testing on water lines?
o A) To check for leaks and verify pressure capacity
o B) To inspect the internal diameter of the pipe
o C) To measure the pipe's resistance to chemicals
o D) To evaluate the pipe's visual appearance

Answer: A) To check for leaks and verify pressure capacity
Explanation: Hydrostatic pressure testing ensures that water lines can withstand the
required pressure without leaking.

18. When monitoring hydrostatic pressure testing, which of the following is a critical
factor?
o A) Temperature of the water
o B) Duration of the test
o C) Surface color of the pipe
o D) Pipe's brand name

Answer: B) Duration of the test
Explanation: The duration of the test is crucial to ensure that the pipe maintains
pressure over time without any leaks.

19. What is tested to ensure water quality in water systems?
o A) Chlorine residual and bacteria levels
o B) Aesthetic appearance of the water
o C) Cost of water supply
o D) Water temperature




4
74,72 €
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Reseñas de compradores verificados

Se muestran los comentarios
10 meses hace

The same questions were repeated numerous times, a scam!

2,0

1 reseñas

5
0
4
0
3
0
2
1
1
0
Reseñas confiables sobre Stuvia

Todas las reseñas las realizan usuarios reales de Stuvia después de compras verificadas.

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
nikhiljain22 EXAMS
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
811
Miembro desde
1 año
Número de seguidores
29
Documentos
19531
Última venta
19 horas hace

3,5

185 reseñas

5
60
4
42
3
41
2
11
1
31

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes