_____ conduit is too thin to be threaded. - Correct Answer EMT ??? are intended for the electrical protection of personnel. - Correct Answer GFCIS 208. A heat trace cable is installed on a line that will be insulated, when should it be megged? - Correct Answer Before and after the insulation is put on 4 inch square boxes are available with all of the following depths EXCEPT - Correct Answer 1 inch A "megger" will be used to check a cable. The electrician MUST be sure thát the circuit is - Correct Answer De energized and locked, tagged out, and tested A 1 line diagram with simplified symbols indicates the - Correct Answer Interconnections and component parts of an electrical circuit A 10-inch offset at 30 degrees is being made. What is the distance between center-to-center bends? - Correct Answer 20 inches A 120/208 volt feeder consists of an 800 ft run of 500 kcmil aluminum wire in conduit. This feeder has 5% voltage drop. What will the phase-to-phase voltage be at the load end? - Correct Answer 197.60 volts A 3 way switch, is what typeof switch/ - Correct Answer SPDT A 3-phase, 4-wire, 480v service requires ______ current transformer(s) - Correct Answer 3 A box has two 12/2 with ground cables in it, all like-colored wires have been spliced and "pigtail", how many #12 conductors should be counted in the box fill? - Correct Answer 5 A brass-colored terminal on a receptacle indicates that it should be used to connect what type of wire? - Correct Answer Hot wire A cable rated for 5KV insulation can safely carry what MAXIMUM voltage? - Correct Answer 5,000 volts A conduit bending Hickey can be used to bend conduit from? - Correct Answer 0-15 degrees A DC ammeter is connected? - Correct Answer In series with the circuit A device labeled CO/ALR can be used with ______ wire. - Correct Answer Aluminum, copper, or copper-clad aluminum A drawing showing a point A to point B hookup of conductors is called a - Correct Answer Wiring diagram A dropout plate is best described as a. - Correct Answer Plate with a curved surface for cable to follow as it passes from the tray A good electrical connection should - Correct Answer Be mechanically and electrically secure A grounding electrode conductor must be connected _____ of a main distribution panel. - Correct Answer To the neutral terminal bus A heat trace cable is installed on a line that will be insulated. When will the cable be "megged"? - Correct Answer Before and after the insulation is put on the line A holding contact in a motor starter normally connected in parallel with? - Correct Answer The start push button

Mostrar más Leer menos
Institución
The Electrical NCCER
Grado
The electrical NCCER









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
The electrical NCCER
Grado
The electrical NCCER

Información del documento

Subido en
17 de septiembre de 2024
Número de páginas
12
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

The electrical NCCER test Questions All
Solved Correctly
_____ conduit is too thin to be threaded. - Correct Answer EMT

??? are intended for the electrical protection of personnel. - Correct Answer GFCIS

208. A heat trace cable is installed on a line that will be insulated, when should it be megged? - Correct Answer
Before and after the insulation is put on

4 inch square boxes are available with all of the following depths EXCEPT - Correct Answer 1 inch

A "megger" will be used to check a cable. The electrician MUST be sure thát the circuit is - Correct Answer De-
energized and locked, tagged out, and tested

A 1 line diagram with simplified symbols indicates the - Correct Answer Interconnections and component parts of an
electrical circuit

A 10-inch offset at 30 degrees is being made. What is the distance between center-to-center bends? - Correct
Answer 20 inches

A 120/208 volt feeder consists of an 800 ft run of 500 kcmil aluminum wire in conduit. This feeder has 5% voltage
drop. What will the phase-to-phase voltage be at the load end? - Correct Answer 197.60 volts

A 3 way switch, is what typeof switch/ - Correct Answer SPDT

A 3-phase, 4-wire, 480v service requires ______ current transformer(s) - Correct Answer 3

A box has two 12/2 with ground cables in it, all like-colored wires have been spliced and "pigtail", how many #12
conductors should be counted in the box fill? - Correct Answer 5

A brass-colored terminal on a receptacle indicates that it should be used to connect what type of wire? - Correct
Answer Hot wire

A cable rated for 5KV insulation can safely carry what MAXIMUM voltage? - Correct Answer 5,000 volts

A conduit bending Hickey can be used to bend conduit from? - Correct Answer 0-15 degrees

A DC ammeter is connected? - Correct Answer In series with the circuit

A device labeled CO/ALR can be used with ______ wire. - Correct Answer Aluminum, copper, or copper-clad
aluminum

A drawing showing a point A to point B hookup of conductors is called a - Correct Answer Wiring diagram

A dropout plate is best described as a. - Correct Answer Plate with a curved surface for cable to follow as it passes
from the tray

A good electrical connection should - Correct Answer Be mechanically and electrically secure

A grounding electrode conductor must be connected _____ of a main distribution panel. - Correct Answer To the
neutral terminal bus

A heat trace cable is installed on a line that will be insulated. When will the cable be "megged"? - Correct Answer
Before and after the insulation is put on the line

A holding contact in a motor starter normally connected in parallel with? - Correct Answer The start push button

, A holding contact na motor starter is normally connected in parallel with the - Correct Answer Start push button

A quick test that can be made to determine if an installation is good is known as a(n) _ test. - Correct Answer Go/No
Go

A section of a cable tray that makes 2 vertical 90 degree turns is known as? - Correct Answer A vertical "T"

A sectional drawing is a? - Correct Answer Cutaway view of a building or object

A switch labeled "AL-CU" can be used with what type of wire? - Correct Answer Aluminum Copper or Copper Clad
Aluminum

A transformer has 200 turns in the primary, 150 turns in the secondary, and 120VAC applied to the primary. The
voltage across the secondary is: - Correct Answer 90Volts

A transformer has a turn ratio of 5:1, what will be the voltage on the secondary if primary voltage is 120v? - Correct
Answer 24 volts

A transformer with 100 turns in its primary coil and 10 turns in its secondary coil is a_ transformer. - Correct Answer
Step-down

A transformer with the primary of 400 turns and a secondary of 300 turns has a _____ - Correct Answer Step-down
turns ratio of 4:3

A Type ?? conduit body has a threaded straight hub on each end and another threaded hub perpendicular to these
two. - Correct Answer T

A voltage of 1 volt applied across a resistance of 1 ohm produces a current of 1 amp. If the voltage is doubled and
the resistance is halved, then the current - Correct Answer Increases 4 times

A voltmeter is connected in. - Correct Answer Parallel with the circuit

A VOM measures - Correct Answer Ohms, amps, and volts

A(n). ______ operates on the same principle as a current transformer. - Correct Answer Clamp-on ammeter

According to Ohm's Law, the amount of current in a circuit is equal to the - Correct Answer Voltage divided by the
resistance

After a hazard review is completed, ________ determine(s) the classification of a confined space as a nonpermit or
permit-required confined space - Correct Answer The supervisor and project/safety managers

All of the following apply to the installation of junction boxes, splices boxes, and pull boxes except that they must be?
- Correct Answer Metal

All of the following are common service voltages in the United States EXCEPT: - Correct Answer 372/575 3-PHASE,
4-WIRE

All of the following are found on an elevation view of a motor control center, EXCEPT - Correct Answer LOCATION
OF MOTOR

All of the following are standard fuse size EXCEPT? - Correct Answer 550 or 601

All of the following are standard fuse sizes EXCEPT - Correct Answer 550 AMP

All of the following connectors may be used for splicing high voltage cable EXCEPT? - Correct Answer Split-bolt
connectors

All of the following information is found on a one-line diagram of a substation EXCEPT? - Correct Answer The Scale

All of the following rating appear on a circuit breaker nameplate, except - Correct Answer Rated wattage
10,92 €
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
chaserdreamer

Conoce al vendedor

Seller avatar
chaserdreamer EXAMS
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
1 año
Número de seguidores
0
Documentos
128
Última venta
-

0,0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes