100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NYC FSD Test Questions And Answers

Puntuación
-
Vendido
-
Páginas
50
Grado
A+
Subido en
18-01-2024
Escrito en
2023/2024

NYC FSD Test Questions And Answers Impairment Coordinator - ANS Person responsible for ensuring the proper safety precautions are taken when the protection system is placed out of service (designated by the owner). How many feet of hose would be found at the standpipe outlet ? - ANS 125 feet In fire prevention there are three areas to consider: - ANS Education (building tenants) Engineering (layout, suppression systems etc) Enforcement(Building codes, Fire codes) Fire Drill Frequency for Group B - ANS Twice a year Fire Drill Frequency for Group R1 - ANS Quarterly each year Refresher training for Group B - ANS 1 hour annually (training) Refresher Training for Group R 1 - ANS 1 hour quarterly on each shift The fire alarm system on your buildings 4th floor has stop functioning. In this case, the fire alarm system would be deemed: - ANS out-of-service It shall be unlawful to transmit unnecessary or unwarranted alarms in any six-month period if the amount of those alarms is: - ANS three or more Which of the following statements is accurate ? A. Activation of a manual pull box shall not be construed as an unnecessary alarm. B. Activation of a manual pull box shall not be construed as an unwarranted alarm. C. Activation of a manual pull box shall not be construed as an unattended alarm. D. Activation of a manual pull box shall not be construed as a disfunctional alarm. - ANS A. Activation of a manual pull box shall not be construed as an unnecessary alarm. 5. The fire alarm system on the15th floor is unable to function in conformance with the law. In this case, the FSD should promptly notify: A. the tenants occupying the 15th and 16th floors B. the tenants occupying the 15th, 16th and 17th floors C. the tenants occupying the 15th and 14th floors D. the tenants occupying the 15th floor - ANS D. the tenants occupying the 15th floor (occupants of the affected area). 6. An alarm log book shall be maintained on the premises. In general, where should it be kept ? A. in the Property Managers Office B. in the Chief Engineers Office C. in the Mechanical Equipment Room D. at the fire command station - ANS D. at the fire command station 7. Which of the following statements about the Alarm Log Book is incorrect? A. shall be a bound book (other than spiral bound) B. all entries shall be made in ink and dated C. shall be retained for a period of two years from the date of the last entry D. separate log book shall be kept for each calendar year - ANS C. shall be retained for a period of two years from the date of the last entry - 3 years not 2. 8. The interior fire alarm pull stations are positioned at the natural exits on each floor of the building. In larger buildings the fire alarm pull stations must be spaced so that the distance between stations does not exceed A. 200 feet B. 150 feet C. 300 feet D. 100 feet - ANS A. 200 feet 9. Interior fire alarm pull stations must be securely mounted to the wall A. at eye level

Mostrar más Leer menos
Institución
FDNY S-92
Grado
FDNY S-92











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
FDNY S-92
Grado
FDNY S-92

Información del documento

Subido en
18 de enero de 2024
Número de páginas
50
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

11,38 €
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyclock Ashford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
848
Miembro desde
3 año
Número de seguidores
492
Documentos
8831
Última venta
2 horas hace

4,2

222 reseñas

5
131
4
35
3
34
2
10
1
12

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes